Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
High Line Pressure Wet-Wet Differential Transducer
PX509HL Series
PLACE ORDER - High 0.08% Accuracy with NIST Traceable Calibration Certificate
- Low Differential Pressure at High Line Pressures, 2000 psi Standard
- Bidirectional or Unidirectional Outputs (± 5 Vdc and 0-5 Vdc, ±10 and 0-10 Vdc, or 4-12-20 and 4-20 mA)
- Line Pressure Error Compensation 0.3% (FS) per 1k psi
- Solid State Sensor for Long Term Stability
- 316L SS Wetted Parts and Welded Stainless Steel Construction
- Shock and Vibration Rated
- Ruggedized Containment Pressures up to 10,000 psi
- Demountable Electrical Termination Available
Description
Description
The PX509HL Series industrial high line pressurewet/wet differential pressure transducersare rugged shock and vibrationrated with high accuracy and arespecifically designed to provide longlife in demanding industrial areas.The compensated overload rangeminimizes errors induced by highline pressures.Features include welded stainlesssteel construction, user accessiblepotentiometers for zero andspan, and demountable electricalterminations or a fixed conduit fittingwithout trim pots.
They are temperature compensatedover a broad range providingexcellent thermal properties andhigh long term stability. A precisionmicromachined silicon sensor isat the core and provides a verystable reading with exceptional highaccuracy of 0.08% and a broadcompensated range of-20 to 85°C on most ranges.
Modular construction allows for fastdelivery of most configurations,customized models also can bedeveloped quickly to suit your exactneeds. PX509’s ordered with the½ NPT conduit fitting (PX509C) donot have a demountable terminationand side accessible trim potsare optional.
SPECIFICATIONS
Calibration: 5-point NIST traceable calibration with zero and span values
Accuracy: ±0.08% best straight line (linearity, hysteresis and repeatability combined) calibrated in vertical direction with fitting down; compound gage models calibrated in positive direction only
Setting Accuracy for Conduits Without Trim Pots:
Zero: ±0.5% full scale typical ±1% maximum (for ranges ≤2.5 psi ±1% typical ±2% maximum)
Span: ±0.5% full scale typical ±1% maximum (for ranges ≤2.5 psi mb ±1% typical ±2% maximum)
Operating Temperature Range: -40 to 85°C (-40 to 185°F)
Compensated Temperature Range:
Ranges ≤5 psi: -17 to 85°C (0 to 185°F)
Ranges >5 psi: -29 to 85°C (-20 to 185°F)
Temperature Compensation:
Zero and Span Effects Over Compensated Range
Range ≤5 psi:
Zero: 1%
Span: 1%
Ranges >5 psi:
Zero: 0.50%
Span: 0.50%
Compensated Line Pressure Range: 0 to 2000 psi
Line Pressure Compensation:
Zero and Span Effects
Zero: 0.3% full scale/1000 psi
Span: 0.3% full scale/1000 psi
Minimum Isolation between Case and Output Terminations: 100Ω O @ 50 Vdc
Pressure Cycles: 1 million, minimum
Long Term Stability (1-Year): ±0.1% full scale typical
Shock: 50 g, 11 mS half sine vertical and horizontal axis
Vibration: 5-2000-5 Hz, 30 minute cycle, Curve L, Mil spec 810 figure 514-2-2, vertical and horizontal axis
Bandwidth: DC to 1 kHz typical
Response Time: <10 mS
CE Compliant: Meets industrial emissions and immunity standard EN61326-1, EN61326-2-3 industrial level 2
Amplified Voltage Output
0 to 5/±5 Vdc: 10 to 32 Vdc, 10 mA
0 to 10/±5 Vdc: 16 to 32 Vdc, 10 mA 4 to 20/4-12-20 mA Output
Output: 4 to 20 mAdc
Supply: 16 to 32 Vdc maximum loop resistance Ohms = (Vs-10) x 50
Environmental Protection: IP65 or IP67 depending upon electrical termination
Safe Overpressure: 5000 psi
Burst Pressure: 10,000 psi
Pressure Connection: ¼ NPT female
Wetted Parts: 316L SS
Weight: 285 g (10 oz) typical Anemometer | Automation | Accelerometers | Calibrator | Cartridge Heaters | Chart Recorders | Cryogenics | Custom Pressure Transducers | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Fiber Optic Temperature Measurement | Flexible Heaters | Flow Meters | Glass Bulb Thermometers | Grippers | Heaters | Humidity Measurement | Integrated Circuit Sensors | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells | M12 Temperature Connectors | Magnetic Flow Meter | Panel Meter | PID Controllers | pH meter | Pressure Gauges | Pressure Transducers | Pressure Transmitters | Rotameters | RTD | Remote Process Monitoring | Sanitary Sensors | Signal Conditioners | Stepper Motors | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Sensor Manufacturing | Temperature Sensors | Temperature Transmitters | Thermal Imagers | Thermistors | Thermocouple | Thermocouple Wire | Thermowell | Ultrasonic Flow Meters | Vortex Flow Meter | Wireless Sensors
trodeks.comtrodeks.com - فقخیثنس.زخئ - صصص.فقخیثنس.زخئ