Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
Milliamp Loop Calibrator
CL530
PLACE ORDER - Source, Measure, Simulate, Read all 4-20 mA Process Loop Functions
- Check 4 and 20 mA Span Limits
- One-Handed Operation with Hands-Free Stepping/Ramping
- Display mA or %
- 0.012% Accuracy.
Specs Manuals (contact with email : info@trodeks.com)
Print
Description
Description
The CL530 builds on trodeks’s30 years of calibration experience.The user can check, calibrate, andtroubleshoot 4 to 20 mA processcontrol loops with this easy-to-useinstrument.
The CL532 has all the features ofthe CL530, plus it will read up to30 Vdc and source up to 24 Vdc.
SPECIFICATIONS
Accuracy: ±0.012% rdg + 0.004 mA
Temperature Effect: ±50 ppm/°C
Operating Temperature Range: -20 to 60°C (-5 to 140°F)
Storage Temperature Range: -30 to 60°C (-22 to 140°F)
Relative Humidity Range: 10% ≤RH ≤90% [0 to 35°C (32 to 95°F)], non-condensing; 10% ≤RH ≤70% [35 to 60°C (95 to 140°F)], non-condensing
Overvoltage Protection: 120 Vrms for 30 seconds, 240 Vrms for 15 seconds
Overload Protection: 24 mA nominal
Battery: 9V, alkaline (included)
Battery Life:
Source Mode: ≥18 hours at 12 mA (HartR disabled)
Power Measure: 10 hours, read, 2 W limit sim.
Read Vdc: >40 hours
Loop Drive Ability: 1200 Ω at 20 mA for life of battery
Loop Burden: <2V at 20 mA Loop Supply Limits (2 W Limit Sim.): 2 to 60 Vdc
Connection: Alligator test leads attached, 610 mm (24") long
Dimensions: 84 W x 180 H x 56 mm D (3.3 x 7.1 x 2.2")
Weight: 326 g (11.5 oz)
Source Current: Source 0 to 24 mA or -25 to 125% into ≤1200 Ω; a flashing HIGH Ω indicator appears if improperly connected
2-Wire Transmitter Simulate: Adjust loop current from 0 to 24 mA or -25 to 125% when powered by an external supply; LOW SUPPLY flashes to indicate a misconnection
Power Measure: Power the loop and read 0 to 24 mA or -25 to 125%; CURRENT LIMITED flashes at >24 mA, protecting devices in the loop
Read Current: Read 0 to 24 mA or -25 to 125%; CURRENT LIMITED flashes at >24 mA, protecting devices in the loop
Read DC Voltage: Read 0 to 60 Vdc with 2x overrange ability and flashing OVERRANGE indicator
EZ-Check Switch: Gives instant access to 4 and 20 mA or other user-set span limits; in read modes, the EZ-Check switch provides a max/min log of reading
EZ-Step Button: Allows one-handed stepping up and down the span in 6 different step sizes
EZ-Dial Knob: Adjusts output by 0.001 mA (0.01%); push and turn for 100x faster adjustment—by 0.100 mA (1.00%) Anemometer | Automation | Accelerometers | Calibrator | Cartridge Heaters | Chart Recorders | Cryogenics | Custom Pressure Transducers | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Fiber Optic Temperature Measurement | Flexible Heaters | Flow Meters | Glass Bulb Thermometers | Grippers | Heaters | Humidity Measurement | Integrated Circuit Sensors | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells | M12 Temperature Connectors | Magnetic Flow Meter | Panel Meter | PID Controllers | pH meter | Pressure Gauges | Pressure Transducers | Pressure Transmitters | Rotameters | RTD | Remote Process Monitoring | Sanitary Sensors | Signal Conditioners | Stepper Motors | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Sensor Manufacturing | Temperature Sensors | Temperature Transmitters | Thermal Imagers | Thermistors | Thermocouple | Thermocouple Wire | Thermowell | Ultrasonic Flow Meters | Vortex Flow Meter | Wireless Sensors