Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
Product Groups
Rugged Infrared Thermocouple 17° (3:1) Field of View Integral Air Cool-Purge Head
TRODEKS Engineering | Thermocouples, Pressure Transducers, Flow Meters, PID Controllers
OS36-3 Series
PLACE ORDER 
  • High Quality Infrared Thermocouple
  • All Stainless Steel Construction
  • 3:1 Field of View
  • Built-in Air Purge
  • J, K, E or T Thermocouple Output Signal
  • Self-Powered
  • Temperature Compensated
 Manuals (contact with email : [email protected])
 Print
Description

Description

The OS36-3 Series is ideal for use in paint or inkenvironments which require the sensor to be mountedremotely from the target. In addition to the ruggednessand ease-of-use of the original OS36 Series, the newOS36-3 Series is hermetically sealed and is equippedwith an internal air cool/purge system. As do allinfrared thermocouples, this new series exceeds allapplicable NEMA standards and is intrinsically safewhen used with appropriate intrinsic safety barriers.

SPECIFICATIONS
Range CodeTemperature Range (2% accuracy)
50F-18 to 27°C (0 to 80°F)
80F10 to 49°C (50 to 120°F)
98.6F16 to 39°C (60 to 102°F)
140F25 to 80°C (80 to 180°F)
180F70 to 104°C (160 to 220°F)
240F95 to 130°C (200 to 270°F)
280F125 to 155°C (260 to 310°F)
340F145 to 175°C (290 to 350°F)
440F170 to 250°C (340 to 480°F)

Accuracy: ±2% of nominal range; blackbody source
Repeatability: ±1% rdg
Temperature Coefficient: ±0.02% nominal range per °F
Temperature Compensation Range: Complies with ASTM standards over 27 to 93°C (80 to 200°F) range
Operating Ambient Temperature Range: -18 to 85°C (0 to 185°F) with internal cold junction compensation
Air Purge: Built-in
Ambient Temperature Compensation: With air flow of 1.1 SCFM (20 psig), max is 120°C (248°F)
Storage Temperature Range: -45 to 121°C (-50 to 250°F)
Response Time: 80 ms
Spectral Response: 6.5 to 14 microns
Range: -45 to 650°C (-50 to 1200°F)†
Field of View: 17° (3:1)
Minimum Spot Size: 6 mm (0.35")
Output Impedance: 4 to 8kΩ (varies by model)
Dimensions: 45 L x 13 mm Dia. (1.76 x 0.50"); 0.9 m (36") PFA coated lead wires
Weight: 40 g (1.4 oz) with cable
†See chart for linear ranges. Measurement is practical beyond thermocouple table values by use of radiation laws. Polynomials available upon request.

Use the "Part Number Builder" and Spec Sheet toconfigure available versions
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors