Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
Product Groups
Handheld Pressure Calibrators with Interchangeable Pressure Modules
TRODEKS Engineering | Thermocouples, Pressure Transducers, Flow Meters, PID Controllers
PCL-1B
PLACE ORDER 
  • Plug-In Pressure Modules Provide Ranges from 0.25 Inches of Water to 7500 psi
  • Dual Display Shows Applied Pressure and Transducer Output Simultaneously
  • Very High Accuracy to 0.06% of Full Scale
  • Measures Pressure, Voltage, Current, Flow and Leak Rate
 Manuals (contact with email : [email protected])
 Print
Description

Description

The trodeks ® PCL-1B handheld system introduces a new era in pressure calibration standards. This unique instrument measures pressure, flow, vacuum, leak, current, voltage and change-of-state for switch testing. A fully equipped PCL-1B system provides all calibration capabilities needed in virtually all pressure measurement and test applications. Each handheld system consists of a base unit and one or two plug-in pressure modules. An array of pressure modules is available to cover ranges from 0.25 inches H2O through 7500 psi. Modules can be interchanged quickly and easily without the use of tools. Select any combination of modules to meet your application needs. The PCL-1B pressure calibration and test system combines the capabilities of plug-in pressure modules with a wide selection of standard firmware features. This combination of firmware-related features and unlimited pressure sensor interchangeability make the PCL-1B one of the most powerful pressure calibration and test instruments available today.

SPECIFICATIONS

Available Accuracies (% of span compared to standard): ±0.07% of span (ranges below 1 in H2O) ±0.06% of span (from 0/1 through 0/200 in H2O)±0.05% of span (psi ranges only)
Repeatability: * ranges 0/5 psi and above ±0.02% of span (typical) ranges 0/2 psi and below ±0.05% of span
Sensitivity: * + 0.002% of span with damping 1 part in 50,000 (max)( * included in accuracy specifications)
Operating Temp. Range: 0 to 49°C (32 to 120°F)
Compensated Temp. Range: -7 to 49°C (20 to 120°F)
Reference Temperature: 21°C ±1.7°C (70° ±3°F)
Temperature Error: maximum of ±0.007% of span per over the compensated range for zero and span
Storage Limits: -20 to 70°C (-4 to 158°F)
Display: Alphanumeric LCD, 9.4 mm (0.37") height per 2 lines, 16 characters/line
Display Update: 100 ms
Process Connection: 1 /8 NPT, internal thread
Electrical Connection: Miniature recessed banana jacks
Housing: Molded, high-impact ABS case, gray
Weight: Base unit: 1.3 kg (2.2 lb) Pressure Module: 0.3kg (0.5lb) each
Dimensions: 200 L x 108 W x 83 mm H (7.88 L x 4.24 W x 3.25" H) nominal
Power Supply: Internal: 9 Vdc batteries (2 required) included External: ac adaptor 9 Vdc, 500 mA
Portable Operation: 30 hours on two 9 Vdc alkaline batteries

PLUG IN PRESSURE MODULES
(psi) RANGES
GAGE PRESSURE
MODEL NO. RANGE (psig)
PCL-MB-005G 0-5
PCL-MB-010G 0-10
PCL-MB-015G 0-15
PCL-MB-020G 0-20
PCL-MB-030G 0-30
PCL-MB-050G 0-50
PCL-MB-100G 0-100
PCL-MB-250G 0-250
PCL-MB-300G 0-300
PCL-MB-500G 0-500
PCL-MB-600G 0-600
PCL-MB-1KG 0-1000
PCL-MB-1.5KG 0-1500
PCL-MB-2KG 0-2000
PCL-MB-2.5KG 0-2500
PCL-MB-3KG 0-3000
PCL-MB-5KG 0-5000
PCL-MB-6KG 0-6000
PCL-MB-7.5KG 0-7500
COMPOUND RANGES
PCL-MB-05BG ±5
PCL-MB-010BG ±10
PCL-MB-15V30BG -15 to 30
PCL-MB-15V60BG -15 to 60
VACUUM RANGES
PCL-MB-10VG 0 to -5
PCL-MB-10VG 0 to -5
PCL-MB-15VG 0 to -15
ABSOLUTE PRESSURE MODULES
MODEL NO. RANGE (psia)
PCL-MB-005A 0-5
PCL-MB-010A 0-10
PCL-MB-015A 0-15
PCL-MB-020A 0-20
PCL-MB-030A 0-30
PCL-MB-050A 0-50
PCL-MB-100A 0-100
PCL-MB-250A 0-250
PCL-MB-300A 0-300
PCL-MB-500A 0-500
PCL-MB-1KA 0-1000
PCL-MB-1.5KA 0-1500
PCL-MB-2KA 0-2000
PCL-MB-2.5KA 0-2500
PCL-MB-3KA 0-3000
PCL-MB-5KA 0-5000
PCL-MB-6KA 0-6000
PCL-MB-7.5KA 0-7500
PLUG IN PRESSURE MODULES
UNIDIRECTIONAL
MODEL NO. RANGE (InH2O)
PCL-MA-0.25WC 0-0.25
PCL-MA-0.5WC 0-0.5
PCL-MA-01WC 0-1.0
PCL-MA-02WC 0-2.0
PCL-MA-03WC 0-3.0
PCL-MA-05WC 0-5.0
PCL-MA-10WC 0-10
PCL-MA-15WC 0-15
PCL-MA-25WC 0-25
PCL-MA-50WC 0-50
PCL-MA-100WC 0-100
PCL-MA-150WC 0-150
PCL-MA-200WC 0-200
BIDIRECTIONAL
PCL-MA-0.125BWC ± 0.125
PCL-MA-0.25BWC ± 0.25
PCL-MA-0.5BWC ± 0.5
PCL-MA-01BWC ± 1.0
PCL-MA-1.5BWC ± 1.5
PCL-MA-2.5BWC ± 2.5
PCL-MA-05BWC ± 5.0
PCL-MA-7.5BWC ± 7.5
PCL-MA-12.5BWC ±12.5
PCL-MA-25BWC ± 25
PCL-MA-50BWC ± 50
PCL-MA-100BWC ± 100
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors