Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
Product Groups
High Performance Digital Thermometer and Digital Multimeter
TRODEKS Engineering | Thermocouples, Pressure Transducers, Flow Meters, PID Controllers
HHM9007R
PLACE ORDER 
  • Digital Thermometer and Multimeter with 60,000 Count LCD Display
  • 0.08% Basic Accuracy
  • Free Communications Software Included
  • Includes Windows® 7 & 8 Compatible Software CD, USB Cable for Remote Communication
  • Measures True RMS AC & DC Voltage, Current, Resistance, Conductance, Capacitance, Frequency, Diode Test
  • Auto Power-Off
  • Temperature, Capacitance, Frequency Measurement, Min/Max, Relative, Hold
  • All Current Ranges are Fuse Protected
  • IEC61010 1: CATIII 1000V, CAT IV 600V
 Specs
 Manuals (contact with email : [email protected])
 Print
Description

Description

The HHM9007R is a fullfeatured, high performancedigital multimeter (DMM) builtwith a double molded case tosupport rugged use and improvedgripping. The meter comes withCD software and a USB cablefor remote communications. Thisversatile, value priced DMMmeasures voltage, current,resistance, conductance,capacitance, and frequency aswell as additional componentand diode test features. TheHHM9007R comes completewith an trodeks Type K beadedwired thermocouple to measuretemperature.

Specifications
Crest Factor: ≤3 at full scale and =6 at half scale
AC Coupled True RMS: Specified from 2 to 100% of range
High Frequency Reject:
    HFR1: >1 kHz
    HFR2: >100 kHz
Peak Hold Accuracy: ±(3.0% rdg + 500 dgts) 45 to 500 Hz on AC 60V to 750V ranges
Overload Protection: 1000 Vdc or 750 Vac RMS
Voltage Burden: 500 mV on 600 µA, 60 mA ranges, 2V on 6000 µA, 400 mA, 20 A ranges
Input Protection: 0.5 A/1000V fast blow ceramic fuse (6.3 x 32 mm) on µA/mA input; 20 A/600V fast blow ceramic fuse (10 x 38 mm) on 20A input
20A Input: 20A for 30 seconds maximum cooling period followed by 10 minutes
Crest Factor: ≤3 at full scale and ≤6 at half scale
AC Coupled True RMS: Specified from 2 to 100% of range
Peak Hold Accuracy: ±(3.5% rdg+500 dgts) 45 to 500 Hz on AC current range
Continuity Test
Range: 600Ω
Audible Threshold: Less than 40Ω
Response Time: Approximately 100 ms
Open Circuit Volts: -3.0 Vdc
Overload Protection: 600 Vdc or 600 Vac RMS
Diode Test
Range: 2V
Resolution: 1 mV
Accuracy: ±(2.0% red+10d)
Test Current: 0.5 mA
Open Circuit Volts: 3.0 Vdc typical
Audible Indication: Less than 0.05V
Overload Protection: 600 Vdc or 600 Vac RMS
Conductance (6000 Counts)
Range: 60 ns
Resolution: 0.01 ns
Accuracy: ±(1.0% red+10d)
Open Circuit Volts: -0.7 Vdc
Equivalent Resistance Range: 16.7MΩ to 100Ω (S = Siemens = 1 / Ω ), (0.01ns = 100Gs), (0.1ns = 10GΩ), (1ns = 1000MΩ), (10ns = 100MΩ), (60.0ns = 16.7MΩ)
Overload Protection: 600 Vdc or 600 Vac RMS
% Duty Cycle
Range: 5 to 95%
Resolution: 0.1%
Pulse Width: >10µs
Accuracy (5V Logic): ±(2.0% red+10d)
Frequency Range: 5 to 95% (40 Hz to 1 kHz), 10 to 90% (1 kHz to 10 kHz), 20 to 80% (10 to 20 kHz)
Overload Protection: 600 Vdc or 600 Vac RMS
Overload Protection: 600 Vdc or 600 Vac RMS
Display: 60,000 counts, 60 segments analog bar-graph
Polarity: Automatic, (-) negative polarity indication
Overrange Indication: ( OL ) or ( -OL ) is displayed
Low Battery Indication: When changing a new battery, the LCD will show the battery capacity with full status ( ); if the operation lasts for a few hours, the capacity indication may show half battery status ( ); after a long time operation, the battery may be exhausted and low battery status is shown ( ); when the “bAtt” is displayed along with a continuous beeping sound and the meter shuts down in 5 seconds, then no further measurement is allowed
Measurement Rate: 2.0/sec, nominal; 20/sec, analog bar-graph
Operating Environment: 0 to 50°C at <70% RH
Storage Environment: -20 to 60°C at <80% RH
Temperature Coefficient: 0.1 x (specified accuracy) per °C (0 to 18°C, 28 or 50°C)
Auto Power Off: Approximately 30 minutes
Altitude: 2000 m (6561.7')
Power: Single 9V battery (included)
Battery Life: 25 hours typical with carbon-zine, 50 hours typical with alkaline
Size: 198 H x 90 W x 44 mm D (7.8 x 3.6 x 1.7")
Weight: Approximately 400 g (14.1 oz) including battery
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors