Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
Product Groups
Portable Handheld Data Logger
TRODEKS Engineering | Thermocouples, Pressure Transducers, Flow Meters, PID Controllers
OM-DAQPRO-5300
PLACE ORDER 
  • 8 Channel Datalogger - Measures Voltage, Current, PT100 RTD, J, K, T Thermocouples, 2252 Ω or 10 K Ω Thermistors, Frequency/Pulse Input
  • Alarm Output
  • 16-Bit Sampling Resolution
  • Fast USB Communications
  • Rapid Sampling - Up to 4000 Samples/Sec (Single Channel Burst Mode)
  • Large Data Storage - 512 K Samples
  • Graphical Display - Shows Collected Data as Measured Values, Graphs or Tables
  • Multiple Logging Sessions - Stores up to 100 Recording Sessions
  • Powerful Analysis Software for Windows 98/NT/2000/ME/XP/VISTA/7
  • See also our OM-DAQXL Series 8 or 16 Channel Universal Input Touch Screen Data Loggers
 Manuals (contact with email : [email protected])
 Print
Description

Description

The OM-DAQPRO-5300 is aneight-channel portable dataacquisition and logging systemwith graphic display and built-inanalysis functions.The dataloggeris powered by an internalrechargeable battery and is capableof sampling,processing anddisplaying measurements withoutbeing connected to a computer.The OM-DAQPRO-5300 is aprofessional,cost-effective,compact and stand-alone datalogging system that can be usedwith a wide variety of applications.This 16-bit, high-resolution, eight-channel datalogger has graphicdisplays and analysis functions formeasuring voltage,current andtemperature in real-time. With itshigh resolution and fast analogto digital converter (ADC), the OM-DAQPRO-5300 meets the majorityof data logging requirements inmost industrial applications. Itsunique ability to display measuredvalues and analyze them in real-time on a graphical interfaceminimizes the need to downloadcollected data to acomputer for furtheranalysis. EveryOM-DAQPRO-5300datalogger is embeddedwith a unique serial numberand can be loaded with adescriptive comment for safeidentification.

The datalogger is very easy touse because all its functionsare broken down into an 8-iconmenu.The four buttons on thedatalogger ’s front keypad can beused to browse every menu andexecute any of the commands.

Inputs
The OM-DAQPRO-5300 has eightinput channels for measuringvoltage, current, temperature andpulses. User selectable input types/ranges are 0 to 24 mA, 0 to 50 mV,0 to 10 V, 2252 Ω or 10 K Ωthermistors, PT100 RTDs, type J, Kor T thermocouple temperaturesensors, internal temperature, pulsecounter, frequency meter and up to20 user defined sensors (used forscaling analog voltage or currentinputs in engineering units).

The OM-DAQPRO-5300 can recorddata from up to eight 2-wire or four3-wire PT100 RTD inputs (two inputchannels are required for each3-wire PT100 RTD inputconnected).Frequency/pulsecounter is only available for input 1.

The datalogger provides a simpleand straight forward tool for definingup to 20 custom sensors. Almostany 0 to 10 V and 4 to 20 mAsensor or transducer can bedisplayed and scaled in meaningfulengineering units, e.g., psi or gpm.The sensor definitions are stored inthe datalogger ’s memory and areadded to the sensors list. Thesensor ’s readings are displayed inthe user-defined units both on theOM-DAQPRO-5300 ’s LCD screenand the Windows software.

The inputs use pluggable screwterminal blocks for easy connection.An internal clock and calendarkeeps track of the date and time ofevery sample measured.

Outputs
The OM-DAQPRO-5300 canautomatically activate an externalalarm device, e.g., energize anaudible alarm or turn on a warninglight,when an input channel isoutside a specified range(Input/Output 8 serves as either aninput or an alarm output). Theexternal alarm device (audible orvisual alarm) is connected to thescrew terminals of Input/Output 8.The alarm output is an opencollector output which is analogousto an electrical switch. High/lowalarm levels and also whether or notthe alarm output is activated duringan out-of limit condition can be setfor each input channel individually.

DAQLAB Windows SoftwareThe OM-DAQPRO-5300 systemalso comes with DAQLAB, a powerfulWindows software. When thedatalogger is connected to a PC,live displays can be viewed at ratesof up to 100 samples/sec, andautomatic downloads can be carriedout at higher rates.

The software can display the datain graphs, tables or meters, cananalyze data with variousmathematical tools, or export datato a spreadsheet. The WindowsSoftware also enables you to set upthe datalogger and to sendadvanced commands such as alarmsettings, triggering conditions andtext notes.

Specifications
INPUTS Number of Inputs: 8 differential analog inputs
Input Type: Selectable type for each input; 0 to 24 mA, 0 to 50 mV, 0 to 10 V, 2252 Ω or 10 K Ω thermistor, PT100 RTD, J, K or T thermocouple, pulse and frequency (input 1 only)

0 to 24 mA
Range:
0 to 24 mA
Resolution: 4.76 µA
Accuracy: ±0.5% FS
Loop Impedance: 21 Ω

0 to 50 mV
Range:
0 to 50 mV
Resolution: 3 µV
Accuracy: ±0.5% FS
Input Impedance: 50 M Ω

0 to 10 V
Range:
0 to 10V
Resolution: 200 µV
Accuracy: ±0.5% FS
Input Impedance: 125 K Ω

TEMPERATURE THERMISTOR
Thermistor Type:
2252 Ω/10 K Ω Thermistor, (trodeks 44000 Series)
Range: -25 to 150°C (-13 to 302°F)
Resolution: 0.05°C
Accuracy: ±0.5% FS

TEMPERATURE PT100 RTD
RTD Type:
100 Ω Pt RTD, alpha =0.00385
Range: -200 to 400°C (-328 to 752 °F)
Resolution: 0.1°C (7 m Ω)
Accuracy: -200 to -50°C, ±0.5% of reading; 50 to 400°C, ±0.5% of reading; -50 to 50°C, ±0.5°C
No. of RTD Inputs: up to eight PT100 2-wire channels or four PT100 3-wire channels

INTERNAL TEMPERATURE
Range:
-25 to 70°C (-13 to 158°F)
Resolution: 0.1°C (1 µV)
Accuracy: ±0.5°C

PULSE COUNTER (INPUT 1 ONLY)
OPTOCOUPLER INPUT

Range: 0 to 65000 counts
Resolution: 1 count
Input Signal: 0 to 5 V
Input Impedance: 470 Ω
Bandwidth: 0 to 25 Hz

  FREQUENCY METER (INPUT 1
ONLY) OPTOCOUPLER INPUT

Range: 20 to 4000 Hz
Time Resolution: 6.5 µs
Input Signal: 0 to 5 V
Input Impedance: 470 Ω

GENERAL
A/D SPECIFICATIONS

Noise: 30 µV RMS
Internal Linearity Error: ±0.08% of FSR
Offset Error: 0.1%

OPEN COLLECTOR ALARM OUTPUT (OUTPUT 8)
Maximum Current Sink: 50 mA @5 Vdc (fuse protected)
Input impedance: 50 Ω

COMMUNICATION
USB 1.1 compliant

SAMPLING
Capacity:
512 KB (512,000 samples total)
Analog Sampling Rate: Thenumber of sensors in use limits themaximum sampling rate;1. Maximum sampling rate with onesensor is 4000 samples/sec2. Maximum Temperature samplingrate 1 sample/sec3. Maximum sampling rate with twosensors or more is 1 sample/sec4. Maximum sampling rate with twoPT 100 RTD sensors or more isevery 10 seconds5. Maximum sampling rate with fivesensors or more and at least one isthermistor or thermocouple (J, Kor T) is every 10 seconds6. Maximum sampling rate withseven sensors or more is every10 seconds7. Maximum sampling rate witheight PT 100 RTD sensors or moreis every 10 seconds8. Datalogger displays readings inreal time at rates up to 1 sample/sec9. Datalogger software displaysonline readings at rates up to1 sample/sec
Analog Sampling Resolution: 16-bits

MAN MACHINE INTERFACE
Keyboard:
full keyboard operation - enables manual programming of the datalogger
Display: graphic LCD 64 x 128 pixels

POWER SUPPLY
Power:
internal rechargeable 7.2 V Ni-MH battery, built in battery charger, external 9 to 12 Vdc input via included ac adaptor
Battery Life: 25 hrs between charges

OPERATING TEMPERATURE
Operating Temperature Range:
0 to 50°C (32 to 122°F)

MECHANICAL
Enclosure:
ABS plastic
Dimensions:
182 H x 100 W x 28 mm D
(7.17 x 3.94 x 1.10")
Weight: 450 g (1.0 lb)

STANDARDS COMPLIANCE
CE, FCC
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors
trodeks.comtrodeks.com - فقخیثنس.زخئ - صصص.فقخیثنس.زخئ