Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
16-Channel Differential Input Voltage Card for use with OMB-LOGBOOK and OMB-DAQBOARD-2000 Series
OMB-DBK80
PLACE ORDER - 16 Differential Input Channels
- Unity Gain Combines with OMB-BOARD-2000 Series/OMB-LOGBOOK Gains to Provide Full Scale Inputs from ±156mV to ±10V (±625mV to ±5V)
- Convenient On-Board Screw Terminal Signal Connection
- Compact Form Factor Mounts in any OMB-DBK Compatible Enclosure
Description
Description
The OMB-DBK80 provides16-channels of differential voltageinput for OMB-DAQBOARD-2000Series and OMB-LOGBOOKmeasurement systems. TheOMB-DBK80 can operate at thefull 100 KHz sample rate with nodegradation of publishedperformance. The OMB-DBK80has a single, unity-gain input stageon all channels.
When coupled with the on-boardx1 through x64 programmableinput gains on the OMB- DAQBOARD-2000Series and OMB-LOGBOOKproduct lines, the combinationprovides full-scale input rangesfrom ± 10V down to ±156mV full-scaleinputs. (±625mV to ±5V when used with OMB-DAQBOARD-2000 Series).
The OMB-DBK80’s ultra-low noisedesign allows users to expandtheir input channels up to 256channels, without incurringadditional noise or inaccuraciesdue to the input expansion cards.Up to 16 OMB-DBK80’s can beattached to one A/D system, andcan also be combined with anyother OMB-DBK series expansionand signal conditioning options.
The OMB-DBK80 also has a +5Vor +10V precision voltage sourceon-board (jumper selectable). Thiscan also be used to bias straingages, thermistors, or othertransducers that require biasing.
Specifications
Connector: DBK37 male,
mates with P1 pin-out on an
OMB-DAQBOARD-2000 Series
orOMB-LOGBOOK
User Connections: Screw-terminalsfor signal connection
Gain Ranges: 1, x1
Inputs: 16 differential voltage inputs
Maximum Voltage Range: ±10V
Input Impedance: 20M ohm
Accuracy: +0.025% + 150 µV (typ),
+ 0.1% +250 µV (max)
Maximum Input Voltage
(withoutdamage): 35V
3dB Bandwidth: 2.6 M Hz
CMRR: 80dB
Excitation Voltage:
One channeljumper selectable to +5V or +10V
Excitation Voltage Accuracy:+0.5%
Excitation Voltage Current Limit:
20 mA source, 1 mA sink
Power: 25 mA max from +15V
(with no load on excitation voltage) Anemometer | Automation | Accelerometers | Calibrator | Cartridge Heaters | Chart Recorders | Cryogenics | Custom Pressure Transducers | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Fiber Optic Temperature Measurement | Flexible Heaters | Flow Meters | Glass Bulb Thermometers | Grippers | Heaters | Humidity Measurement | Integrated Circuit Sensors | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells | M12 Temperature Connectors | Magnetic Flow Meter | Panel Meter | PID Controllers | pH meter | Pressure Gauges | Pressure Transducers | Pressure Transmitters | Rotameters | RTD | Remote Process Monitoring | Sanitary Sensors | Signal Conditioners | Stepper Motors | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Sensor Manufacturing | Temperature Sensors | Temperature Transmitters | Thermal Imagers | Thermistors | Thermocouple | Thermocouple Wire | Thermowell | Ultrasonic Flow Meters | Vortex Flow Meter | Wireless Sensors
trodeks.comtrodeks.com - فقخیثنس.زخئ - صصص.فقخیثنس.زخئ