TRODEKS Engineering | Thermocouples, Pressure Transducers, Flow Meters, PID Controllers
NFX9000 Series
PLACE ORDER 
  • V/Hz Control: Provides 150% Starting Torque and Advanced Low Speed Control
  • Easy to Understand Keypad
  • RS485 Serial Communication Port
  • Single-Phase or 3-Phase Input Capability on 115/240 Vac Rated Units
 Specs
 Manuals (contact with email : [email protected])
 Print
Description

Description

The NFX9000 adjustablefrequency AC Drives are designed to provide adjustablespeed control of 3-phase motors. Thesemicroprocessor-based drives have standardfeatures that can be programmed to tailorthe drive’s performance to suit a wide varietyof application requirements. The NFX9000volts-per-hertz product line utilizes a 32-bitmicroprocessor and insulated gate bipolartransistor (IGBTs) which provides quietmotor operation, high motor efficiency andsmooth low speed performance. The sizeand simplicity of the NFX9000 make it idealfor hassle-free installation where size is aprimary concern.Models rated at 240V, single- or3-phase, 50/60 Hz are available in sizesranging from 1/4 to 2 hp. Models rated at115V, single-phase, 50/60 Hz are availablein the 1/4 to 1/2 hp size range. The standarddrive includes a digital display as well asoperating and programming keys on aremovable keypad. The display providesdrive monitoring and diagnostic information.The keys are utilized for digital adjustmentand programming of the drive plus operatorcontrol. Separate terminal blocks for controland power wiring are provided for customerconnections. The drives feature RS485 serialcommunications.

SPECIFICATIONS
OUTPUT RATINGS
Horsepower: 90 to 132V, 1/4 to 1/2 hp,200 to 240V, 1/2 to 2 hp
Frequency Range: 0.1 to 400 Hz
Overload Rating: 150% for 60 sec
Frequency Resolution: Digital, 0.1 Hz
Frequency Accuracy:
    Digital: ± 0.01% of max frequency
    Analog: ± 0.2% of max frequency
Undervoltage Carryover Limit: 0.3 to 25 sec
MOTOR PERFORMANCE
Motor Control: V/Hz
Constant Torque: Standard
Speed Regulation: 0.5% of base speed
INPUT POWER
Voltage: 50/60 Hz, ±3 Hz
100 to 120V: -10% +10%/1-phase
200 to 240V: -10% +5%/1-phase
200 to 240V: -10% +5%/3-phase
Displacement Power Factor: Better than 0.95
Efficiency: Typically greater than 95%
DESIGN TYPE
Microprocessor: 32-bit
Converter Type: Diode
Inverter Type: Insulated Gate Bipolar Transistor
Waveform: PWM V/Hz
ENVIRONMENT
Operating Temperature: -10 to 40°C (14 to 104°F)
Humidity: 20 to 90% non-condensing
Maximum Elevation: 1000 m (3281')
CODES AND STANDARDS
NEMA, IEEE, NEC: Design standards, UL listed, cUL listed, CE marked
Standard Enclosure: Protected chassis (IP20)
PROTECTIVE FEATURES
Ground Fault: Standard
Overload Protection: Standard
Overcurrent: Standard
Overvoltage: Standard
Undervoltage: Standard
Overtemperature: Standard
Overload Limit: StandardSET UP ADJUSTMENTS, PERFORMANCE FEATURES, OPERATOR CONTROL AND EXTERNAL INTERFACE
Keypad:
    Alphanumeric Display: Standard, 1 x 4 character
    Digital Indications: RUN/STOP and FORWARD/REVERSE
    Diagnostics: Last 3 trips with cause
    LED Status Indicators: 4; RUN/STOP and FORWARD/REVERSE
    Operator Functions: RUN/STOP, speed control (digital or potentiometer), RESET, MODE keys and ENTER
I/O TERMINAL BLOCK
Analog Inputs: 1 Input, 0 to 10 Vdc, 4 to 20 mA
Potentiometer: 1 to 2K Ω
Analog Voltage: Nominal 10 Vdc, 10K Ω input impedance
Analog Current: Nominal 4 to 20 mA, 250 Ω
Digital Inputs: 4 programmable inputs
Digital Outputs: 1 form A relay contact
PROGRAMMABLE PARAMETERS
Out of the Box: Factory settings loaded for quick start-up
Acceleration and Deceleration: 2 separately, adjustable linear or S curve times, 0.1 to 600 sec
DC Injection Braking:
    External Fault: Terminal input
    Jog: Terminal input
Fault Reset: STOP/RESET or terminal input
I/O: NO/NC selectable
Jump Frequencies: 3, with adjustable width
Parameter Security: Programmablesoftware lock
Preset Speeds: 2 preset speeds
Reversing: Keypad or terminal
Speed Setting: Keypad, terminal or pot
RUN/STOP Control: Keypad or terminal
Stop Modes: Decel, coast or DC injection
RELIABILITY
Pretested Components: Standard
Surface Mount Technology: Standard, PCBs
Computerized Testing: Standard
Final Test with Full Load: Standard
Engineering Systems and Service: National network of AF drive specialist
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors