PLACE ORDER 
  • High Speed; Up to 52,000 Samples per Second
  • 24-Bit A/D with ±8 Million Counts for Tension and Compression Applications
  • Powerful 32-Bit /135 MIPS DSP for High Speed
    On-Board Processing - OEM Applications Can Be Embedded On The Board
  • 4 Opto-Isolated Outputs Configurable as Setpoints, Latching Alarms or User Outputs
  • 4 Opto-Isolated Inputs; Input #1 Has Counter Option
  • Analog Output—0 to 2.5V, 16-Bit
  • 8-Digit LED Display
  • On Board Temperature Sensor
  • USB 2.0 Interface—Full Speed Compatible
  • RS-232/RS-485 Communications Ideal for PLC Based Applications
  • Multiple Boards May Be Connected
    Via USB or RS-485
 Specs
 Manuals (contact with email : [email protected])
 Print
Description

Description

The LCIC-WIM is a high speed, intelligent loadcell interface card with USB/RS-232/RS-485 interfaces.Besides its basic mode, the board includes an integralFill Mode supplying an independent filling control.The board is intelligent and powerful enough for OEMcustomers—it is ready to accept piggy-back modulesand/or embedded applications for OEM specialrequirements. The LCIC-WIM-BEN is usefulin applications such as analyzing noise and vibration ina belt conveyor or any dynamic weighing system, forexample the time it takes for stabilization after a loadwas applied. Other potential applications includechecking scale behavior for slow/high speed WIM(weighing in motion) applications, measuring maximum(peak) and minimum forces on a scale/testing machine(helps to select the suitable load cell for optimumperformance), and running tests and getting immediatefinal weight results on WIM and check weighers.

LCIC-WIM Software
Three software utilities are supplied with the board:LCIC-WIM-CALIBRATION, LCIC-WIM-SETTINGS andLCIC-WIM-MONITOR. These software utilities enableeasy selection and setup of the required board.The calibration utility (LCIC-WIM-CALIBRATION)enables you to calibrate the LCIC-WIM-BEN board byadjusting it to your own system. The utility is straightforward and is in the form of a Windows® wizard.The LCIC-WIM-SETTINGS utility gives control to card’sfilters, analog output, fill mode parameters and more.

The LCIC-WIM-MONITOR utility is a vital tool foranalyzing dynamic load/force systems. It takes fulladvantage of the board’s speed and samples the loadcell signal at maximum speed (15,000 samples persecond), sending the data to the PC via the USB portand displaying it as a curve—load cell signal/versus time.You can then zoom in/out on the data, view max (peak)and min readings, save the data in standard ASCII fileformat for later use and even perform some calculationslike averaging on a required part of the curve.

Specifications
LOAD CELL INPUT
Bridge Input:
1 input, 4-wire or 6-wire
Excitation: 5 Vdc excitation for up to 10 load cells (350 Ω) in parallel
Compatibility: Compatible with 1, 2 & 3 mV/V load cells

A/D
Speed:
Low noise wide bandwith amplifier, very highspeed, up to 52,000 samples per second
Resolution: 24-bit A/D with ±8 million counts fortension and compression applications

COMMUNICATIONS
Standard Interfaces:
USB 2.0 full speed compatible;combined RS-232/RS-485

INPUTS
Digital Inputs:
4 opto-isolated inputs with 10 to 30 Vdcrange, each with status LED; input #1 configurable ashigh speed counter; input #2 configurable as sampletrigger

OUTPUTS
Relays:
4 opto-isolated solid state relays rated at 50 V,300 mA; configurable as setpoints,
latching alarms oruser outputs, each with status LED
Analog Output: 0 to 2.5 Vdc with 16-bit resolution

GENERAL
Power:
From included 110/220 Vac adaptor
DSP: Powerful 32-bit/135 MIPS DSP for high speedonboard processing
RS-232/485 Port: DB9F connector
I/O Port: DB15M connector(digital inputs, relay outputs, analog output)
Display: 8-digit LED display
Temperature Sensor: On-board
Dimensions: Standard (Eurocard); 160 L x 100 mm W(6.3 x 3.94")
Weight: 251 g (9 oz)
Case: ABS
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors