4-1-2 Digit Thermocouple Meters- 1-8 DIN
TRODEKS Engineering | Thermocouples, Pressure Transducers, Flow Meters, PID Controllers
DP3002-J, -K, -T
PLACE ORDER 
  • J, K or T Thermocouple Input
  • 0.05 deg/deg Cold-Junction Error
  • -138 to 1248°C Range
  • Five-Segment Linearization
  • 0.1°C or 0.1 °F Resolution, Jumper-Selectable
  • 1 mV/deg Linearized Recorder Output
  • 120 dB CMR, 70 dB NMR
  • Bright, 14 mm (0.56") LED Display
  • Display Hold and Test
  • 115/230 Vac Power
  • EMI/RFI Filter for AC Power
  • Screw-Terminal Barrier Strip
  • Short 104 mm (4.1") Deep ¹/8 DIN Case Options
  • Isolated 9 to 32 Vdc Power
  • Isolated 26 to 56 Vdc Power
  • NEMA 4 (IP65) Splash-Proof Lens Cover
 Manuals (contact with email : [email protected])
 Print
Description

Description

The DP3002-J, -K and -T are low-cost 4-1/2 digit(±19,999 count) thermocouple meters with 0.1°C or0.1°F resolution for indication-only applications. Highaccuracy is provided by five-segment linearization andmatched, graded components for each T/C type.

STANDARD FEATURES
Mechanical features include a bright 14 mm (0.56")display, a screw-terminal barrier strip for signal andpower, and a compact 1/8 DIN case that requiresless than 104 mm (4.1") behind the panel. Electricalfeatures include cold-junction compensation, jumperselection of °C or °F, and a linearized recorder outputof 1 mV per degree.

OPTIONS
Power options include isolated 9 to 32 Vdc and26 to 56 Vdc. A splash-proof lens cover which meetsNEMA 4 (IP65) requirements allows the DP3002 to beused in harsh industrial environments.

SPECIFICATIONS
Input
Thermocouple: Type J (Iron-Constantan, Fe-CuNi) Type K (Chromel-Alumel, NiCr-NiAl) Type T (Copper-Constantan, Cu-CuNi)
Calibration: IEC 584-1 (IPTS-68)
Configuration: Single-ended (-TC lead tied to ANA GND)
Polarity: Bipolar
Zero: Adjustable ±20°C (±36°F)
Cold-Junction Tempco: ±0.05 deg/deg Sensor-Wire Resistance Effect Per
Conductor:
Type J: 40 µdeg/deg/Ω, up to 2500 Ω
Type K: 50 µdeg/deg/Ω, up to 2000 Ω
Type T: 50 µdeg/deg/Ω, up to 2000 Ω
Sensor-Break Current: 300 nA
Sensor-Break Indication: Positive overrange (upscale)
Digital Inputs
Level: TTL or 5V CMOS compatible
Noise Rejection
NMR, SIG HI to SIG LO: 70 dB, 50/60 Hz
CMR, ANA GND to PWR GND: 120 dB, DC to 60 Hz
CMV, ANA GND to PWR GND: 1500 Vp per HV test, 354 Vp per IEC spacing
Accuracy at 25°C
Range for Rated Accuracy:
Type J: -138.0 to 760.0°C (-216.0 to 1400.0°F)
Type K: -105.0 to 1248.0°C (-157.0 to 1999.9°F)
Type T: -112.0 to 400.0 °C (-170.0 to 752.0°F)
Maximum Error: ±1.5°C (±2.7°F) ±5 cts
Span Tempco: ±0.01% of reading/°C
Resolution: 0.1°C or 0.1°F (jumper-selectable)
Full-Scale Step Response: 1 s
Warmup to Rated Accuracy: 20 min
Analog Output
Voltage: 1 mV/deg
Calibration Error: ±1.5 mV on °C, ±2.7 mV on °F
Current: 1 mA max
Source Resistance: 68 Ω
Analog-to-Digital Conversion
Technique: Dual-slope, average value
Signal-integration period: 100 ms
Read Rate: 2.5/s
Display
Type: 7-segment, red LED
Height: 14.2 mm (0.56")
Symbols: -1.8.8.8.8
Decimal Points: Four positions programmable by jumpers behind the lens or at connector
Overrange Indication: Four leastsignificant digits flash
Power
AC Voltages: 115 or 230 Vac, ±15%
AC Frequency: 49 to 440 Hz
DC Voltages: 9 to 32 Vdc, isolated to 300 Vp; 26 to 56 Vdc, isolated to 300 Vp
Power Consumption: 3.7 W nominal
Output Voltages: 4.7 Vdc and -4.7 Vdc ±5%, 10 mA max
Environmental
Operating Temperature: 0 to 60°C
Storage Temperature: -40 to 85°C
Relative Humidity: 95% at 40°C (non-condensing)
Mechanical
Bezel: 96 W x 48 H x 5.1 mm D (3.78 x 1.89 x 0.20")
Depth Behind Bezel: 104 mm (4.09")
Panel Cutout: 92 W x 45 mm H (3.62 x 1.77")
Weight: 15 oz (425 g)
Case Material: 94V-0 UL-rated polycarbonate
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors