The rugged high-performance, high power trodeks® zSeries wireless sensor/transmitter system provide Web-based monitoring of Temperature, Humidity, and Barometric Pressure, as well as thermocouples and any transducer with analog voltage or current output. The radio is a High Power IEEE 802.15.4 compliant transmitter operating at 2.4 GHz designed to transmit over greater distances and through more obstructions than the standard transmitter. These wireless sensors transmit up to 1000m (3280’)--without obstructions or interferences to a zCDR coordinator. The coordinators connect directly to an Ethernet network and the Internet and serve active Web Pages to display and chart the data. You can monitor and record Analog Voltage and Current, Temperature, Relative Humidity, and Barometric Pressure over an Ethernet network or the Internet without any special software--just your Web Browser. You can even set alarms to be notified by email. Alarms can be sent to a single user or to a group distribution list, including text messages to cell phones. These zSeries wireless sensors are designed for demanding industrial applications indoors and harsh outdoor environments. The electronics are protected in a rugged weatherproof polycarbonate NEMA4 (IP65) rated housing. The rugged industrial sensors are supplied with ten feet of cable. | |
WIRELESS SENSORS Wireless sensors are available with external probes appropriate for an almost unlimited variety of industrial and commercial applications. trodeks offers a selection of end devices for a variety of applications. The high power end device supports one external sensor. The external sensors are designed for harsh environments such as outdoor weather, in HVAC ducts, in freezers and refrigerators. trodeks offers high power End Devices that run on either AC power, low voltage power, or batteries. The AC version (zED-P, zED-LCD) is powered by a 5 Vdc universal AC power adapter that operates on any voltage worldwide (110 to 240 Vac). Should AC power fail, the unit can operate on a 3.6V ultra-long-life lithium back-up battery (included). A low power option (zED-DC) operates at 10 to 30 Vdc, or 24Vac. The completely wireless End Devices are powered by two C-cell (zED-CCELL) alkaline batteries. These End Devices can operate for weeks, months, or years before changing the batteries. Battery life depends on the type of sensor and other user settings such as the frequency of transmission. | |
ALARM AND EMAIL The zSeries wireless sensor system can trigger an alarm if variables go above or below a set point that you determine. Your alarm can be sent by email to a single user or to a group distribution list, including text messages to cell phones and PDA’s. The trodeks "MailNotifier" software is a free and easy program for this application.The meter-controller connects directly to an Ethernet Network or the Internet. Unlike an RS232 or USB device, it does not require a host computer. EMBEDDED WEBSERVER The wireless sensor system is easy to install, simple to operate, and features trodeks’s award-winning iServer technology with an Embedded Web Server that requires no special software. | |
CHARTS AND GRAPHS The zSeries system serves Active Web Pages to display real time readings and charts of temperature, humidity, and barometric pressure. You can also log data in standard data formats for use in a spreadsheet or data acquisition program such as Excel or Visual Basic. trodeks offers a free and easy to use program for logging data to Excel. The virtual chart viewed on the web page is a JAVA Applet that records a chart over the LAN or Internet in real time. With this wireless system there is no need to invest time and money learning a proprietary software program to log or chart the data. Chart scales are fully adjustable on the fly. For example, the chart can display one minute, one hour, one day, one week, one month or one year. Temperature and humidity can be charted across the full span (-40 to 125°C, and 0 to 100% RH) or within any narrow range such as (20 to 30°C). trodeks offers an OPC Server software that makes it easy to integrate the wireless sensor system with many popular Data Acquisition and Automation programs offered by trodeks, Wonderware, iConics, Intellution, Rockwell Automation, and National Instruments, among others. | | Screen Shots from zSeries | |
QUALITY AND TECHNOLOGY The innovative trodeks® zSeries system features an extended one (1) YEAR warranty at no extra charge. | |
SPECIFICATIONS EXTERNAL SENSOR SPECIFICATIONS | |
TEMPERATURE Accuracy/Range*: zED-TP1 (-P/-LCD/-DC/-CCELL); zED-TP2 (-P/-LCD/-DC/-CCELL) ±0.5°C for 10° to 85°C (±1°F for 50° to 185°F) ±1°C for -40° to 10°C and 85° to 125°C (±1.8°F for -40° to 50°F and 185° to 257°F) zED-BTHP (-P/-LCD/-DC/-CCELL); zED-THP (-P/-LCD/-DC/-CCELL) zED-THP2 (-P/-LCD/-DC/-CCELL) ±0.5°C for 5° to 45°C (±1°F for 41° to 113°F) up to 1.5°C for -40° to 5°C and 45° to 124°C (up to 2.7°F for -40° to 41°F and 113° to 255°F) refer to chart zED-BTP (-P/-LCD/-DC/-CCELL) ±0.8°C @ 20°C (±1.5°F @ 68°F) ±2°C for -40° to 85°C (±3.6°F for -40° to 185 °F) Resolution: 0.1°C Repeatablilty: ±0.1°C, for zED-BTHP, zED-THP, zED-THP2 (zED-P/-LCD/-DC/-CCELL), *Note: extended temperature ranges are for External Probes only Industrial Probe: SS 316 housing, 137mm x ?16mm (5” x ? 0.63”) for zED-BTP (-P/-LCD/-DC/-CCELL); zED-BTHP (-P/-LCD/-DC/-CCELL); zED-THP (-P/-LCD/-DC/-CCELL) Short Probe, Quick Disconnect: SS 316 housing, 78mm x ?16mm (3.1” x ? 0.63”) for zED-THP2 (-P/-LCD/-DC/-CCELL) Stick Probe: ABS tubing, 152.4 mm x ?6.35 mm (6” x ? 0.25”) for zED-TP1 (-P/-LCD/-DC/-CCELL) Lug Mounted Probe: Copper tubing, 53.4 mm x ? 7.92mm (2.1” x ? 0.312”); mounting hole ? 4.72mm (? 0.186”) for zED-TP2 (-P/-LCD/-DC/-CCELL) Cable Dimensions and Operating Temperature: 3 m (10’) long x ? 2.62 mm (0.103”) -80° to 200°C (-112° to 392°F) for zED-THP (-P/-LCD/-DC/-CCELL); zED-TP1 (-P/-LCD/-DC/-CCELL); zED-TP2 (-P/-LCD/-DC/-CCELL) 3 m (10’) long x ? 4.45 mm (0.175”) -55 to 105°C (-67 to 221°F) for zED-BTP (-P/-LCD/-DC/-CCELL); zED-BTHP (-P/-LCD/-DC/-CCELL) | | RELATIVE HUMIDITY Accuracy/Range: zED-BTHP (-P/-LCD/-DC/-CCELL); zED-THP (-P/-LCD/-DC/-CCELL) ±2% for 10 to 90%; ±3% for 5 to 10% and 90 to 95%; ±4% for 0 to 5% and 95 to 100% Hysteresis: ±1% RH Non-linearity: ±3% Repeatability: ±0.1% Resolution: 0.1% BAROMETRIC PRESSURE Accuracy/Range: zED-BTP (-P/-LCD/-DC/-CCELL), zED-BTHP (-P/-LCD/-DC/-CCELL); ±2 mbar for 10 mbar to 1100 mbar (1 KPa to 110 KPa) Resolution: 0.1 mbar THERMOCOUPLE INPUT Temperature Range: refer to Thermocouple Temperature Accuracy: refer to Thermocouple Temperature Stability: 0.08°C/°C Temperature Coefficient: ±25 ppm/°C Thermocouple Cold End Tracking: 0.1°C/°C Thermocouple Lead Resistance: 100 ohm max. Thermocouple Type (ITS 90): J, K, T, E, R, S, B, C, N, L (DIN J) Warm-Up to Rated Accuracy: 30 minutes ANALOG VOLTAGE & CURRENT INPUT Voltage Input: Differential; bipolar; ±100 mV, ±1 V, ±10 V Input Impedance: 400 K ohm for voltage Current Input: Differential; bipolar; ±20 mA (5 Ohm load) Accuracy: ±0.1% Full Range @ 25°C Reading Rate: Periodic (1 sample/update) or continuous (20 samples/second) A/D Conversion: Sigma-Delta Resolution: 16 bits Temperature Coefficient: ±50 ppm/°C Common Mode Rejection: 105 dB Normal Mode Rejection: 98 dB Warm-Up to Rated Accuracy: 30 minutes | |
| | | 2 Thermocouples included with -TC versions versions | Introduction to Thermocouples | Optional Caps available for Industrial Probes | |
ENVIRONMENT Operating Temperature: -20° to 70°C (-4° to 158°F) for zED-P, zED-DC Operating Temperature: -10° to 60°C (14° to 140°F) for zED-LCD-X -18° to 55 °C (-0.4° to 131°F) for zED-CCELL Power Adapter Operating Temperature: 0 ° to 40 °C (32 ° to 104 °F) for zED-P, zED-LCD Enclosure Dimensions: 135.9L x 82.0W x 39.D mm (5.35L x 3.23L x 1.56D") Enclosure Material: Polycarbonate Enclosure Protection: NEMA4(IP65) Warm-Up to Rated Accuracy: 30 minutes WIRELESS COMMUNICATION Standard: IEEE 802.15.4, DSSS Frequency: 2.4 GHz (2400 to 2483.5 MHz), 16 channels Network Topology: Star Topology Range: up to 1000 m (3280 ft) without obstructions or interference. POWER (zED-P, ZED-LCD) Power Input: 5 Vdc Consumption: 0.8 W max Safety Qualified ac Power Adapter (included) Nominal Output: 5 Vdc @ 0.6 A Input: 100 to 240 Vac, 50/60 Hz Lithium Back-up Battery: one 3.6 Vdc, supplied Lifetime: Estimate 2 years with frequency of 1 reading per 2 minutes (7 months for -TC option; 8 months for -VI option)
| | POWER (zED-DC, zED-LCD-DC) Power Input: 10-30 Vdc, or 24 Vac ±10% Consumption: 1.5 W max Isolation Dielectric per 60 Sec: 1000 Vdc POWER (zED-CCELL) Alkaline Battery: two C-cell 1.5 Vdc, supplied Lifetime: Estimate 7 years with frequency of 1 reading per 2 minutes (2.3 years for -TC and -VI option) POWER (zCDR and zCDR-VI) Power Input: 9 to 12 Vdc Consumption: 2.5 W max Safety Qualified ac Power Adapter (included)Nominal Output: 9 Vdc @ 0.5 A Input: 100 to 240 Vac, 50/60 Hz Power Adapter Operating Temperature: 0 ° to 40 °C (32° to 104°F) Universal ac Power Adapter | |
Frequency | zED-TC/VI-LCD-AA | zED-TC/VI-CCELL | Continuous | 5 days | 2 weeks | 10 sec | 5 months | 1.4 years | 30 sec | 7.2 months | 2 years | 60 sec | 7.9 months | 2.2 years | 120 sec | 8 months | 2.3 years | 300 sec | 8.6 months | 2.4 years | | Frequency | zED-TP1/TP2/THP/BTP/BTHP-LCD-AA | zED-TP1/TP2/THP/BTP/BTHP-CCELL | 10 sec | 5.3 months | 1.7 years | 30 sec | 1.1 years | 4.3 years | 60 sec | 1.7 years | 7 years max | 120 sec | 2.5 years | 7 years max | 300 sec | 3.3 years | 7 years max | | |
GENERAL Approvals: CE, FCC: Part 15C. CE: EMC 2004/108/EC, LVD 2006/95/EC, R&TTE 1999/5/EC, SRRC. Software The software packages available for the zSeries wireless system are iConnect (configuration software for the Ethernet interface), iLog (Excel-based software for automatic data logging) and Mail Notifier (email alarm notification software). | |
iLOG Excel program logging the data | iLOG Excel program sketching the data | |
THERMOCOUPLE CHART |
| Input Type | Range | Accuracy | J | Iron-Constantan | -210 to 760°C / -346 to 1400°F | 0.4°C / 0.7°F | K | CHRtrodeks®-ALtrodeks® | -270 to -160°C / -160 to 1372°C -454 to -256°F / -256 to 2502°F | 1.0°C / 0.4°C 1.8°F / 0.7°F | T | Copper-Constantan | -270 to -190°C / -190 to 400°C -454to -310°F / -310 to 752°F | 1.0°C / 0.4°C 1.8°F / 0.7°F | E | CHRtrodeks®-Constantan | -270 to -220°C / -220 to 1000°C -454 to -364°F / -364 to 1832°F | 1.0°C / 0.4°C 1.8°F / 0.7°F | R | Pt/13%Rh-Pt | -50 to 40°C /40 to 1768°C -58 to -104°F / 104 to 3214°F | 1.0°C / 0.5°C 1.8°F / 0.9°F | S | Pt/10%Rh-Pt | -50 to 100°C /100 to 1768°C -58 to 212°F /212 to 3214°F | 1.0°C / 0.5°C 1.8°F / 0.9°F | B | 30%Rh-Pt/6%Rh-Pt | 100 to 640°C / 640 to 1820°C 212 to 1184°F / 1184 to 3308°F | 1.0°C / 0.5°C 1.8°F / 0.9°F | C | 5%Re-W/26%Re-W | 0 to 2320°C / 32 to 4208°F | 0.4°C / 0.7°F | N | Nicrosil-Nisil | -250 to -100°C / -100 to 1300°C -418 to -148°F / -148 to 2372°F | 1.0°C / 0.4°C 1.8°F / 0.7°F | L | J DIN | -200 to 900°C / -328 to 1652°F | 0.4°C / 0.7°F | | REPLACEMENT PROBES & CALIBRATION CERTIFICATES No need to take your unit out of service to get re-calibrated, order a calibrated probe instead. | | Get a NIST Traceable Calibration Certificate with your Calibrated Replacement Probe. | A complete wireless system requires at least: one (1) End Device (zED-x-P, zED-x-LCD, zED-x-CCELL, zED-x-DC or zED-x ) and one (1) Coordinator/Receiver (zCDR).
We recommend the newest & for all the new applications. | | |