Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
Multifunction Thermocouple Calibrator
CL300A
PLACE ORDER - Measures Inputs from 10 Common Thermocouple Types plus mV
- Accepts Miniplugs and Bare Wires
- Simple Decade Control of Output
- 3 Setpoints for Each Thermocouple Type
- Min/Max Recall
- Input Protection to 240 Vac
- Certificate of Calibration
Description
Description
The CL300A multifunctionthermocouple/mV calibratorcombines high accuracy withease of use. Its accuracy of±0.3°C (±0.5ºF) includes all errors,at resolutions of 0.01°C or °F inmeasure mode and 0.1°C or °Fin source mode. Features includemin/max recall in measure mode,3 setpoints per thermocouple type,a large knob for decade control ofthe output in source mode, andcompatibility with both bare-wireand miniplug inputs.
SPECIFICATIONS
(1 Year at 23 ±5°C; % of ReadingUnless Otherwise Noted)
Output Voltage
Range: -10 to 75 mV
Resolution: 1 µV
Accuracy: ±0.007% rdg, ±10 µV
Output Impedance: 1 Ω
Input Voltage
Range: -10 to 75 mV/thermocouple source/measure
Thermocouple Types: J, K, T, E, R, S, B, L, U, C
Resolution
Source: ±0.1°C or °F
Measure: ±0.01°C or °F
Accuracy:
J: ±0.5°C; -210 to -100°C, ±0.3°C; -100 to 1200°C
K: ±0.6°C; -200 to -100°C, ±0.35°C; -100 to 1000°C, ±0.5°C; 1000 to 1372°C
T: ±0.7°C; -200 to -150°C, ±0.3°C; -150 to 400°C
E: ±0.5°C; -200 to -100°C, ±0.3°C; -100 to 1000°C
R: ±1.8°C; 0 to 250°C, ±1.0°C; 250 to 1767°C
S: ±1.8°C; 0 to 250°C, ±1.0°C; 250 to 1767°C
B: ±1.7°C; 600 to 1000°C, ±1.2°C; 1000 to 1820°C
L: ±0.5°C; -200 to -100°C, ±0.4°C; -100 to 900°C
U: ±0.7°C; -200 to 0°C, ±0.3°C; 0 to 600°C
C: ±0.4°C; 0 to°C 1000°C, ±0.7°C; 1000 to 1800°C, ±1.2°C; 1800 to 2316°C
Resolution: 1 ΩVAccuracy: ±0.007% rdg, ±10 ΩV
Input Impedance: >1 MΩ
CJC Temp Offset: ±0.05°C/°C outside of 23 ±5°C
Warm-Up Time: 1 minute to specification
Environmental
Operating Temperature:-10 to 55°C (14 to 131ºF)
Storage Temperature: -20 to 70°C (-4 to 158ºF)
Power Requirement: 9 Vdc
Battery: 9 V alkaline (included)
Optional Power: Ni-Cad battery, AC adaptor/charger
Mechanical
Dimensions: 144.7 H x 80.0 W x 36.3 mm D (5.7 x 3.15 x 1.43")
Weight: 340 g (12 oz) Anemometer | Automation | Accelerometers | Calibrator | Cartridge Heaters | Chart Recorders | Cryogenics | Custom Pressure Transducers | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Fiber Optic Temperature Measurement | Flexible Heaters | Flow Meters | Glass Bulb Thermometers | Grippers | Heaters | Humidity Measurement | Integrated Circuit Sensors | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells | M12 Temperature Connectors | Magnetic Flow Meter | Panel Meter | PID Controllers | pH meter | Pressure Gauges | Pressure Transducers | Pressure Transmitters | Rotameters | RTD | Remote Process Monitoring | Sanitary Sensors | Signal Conditioners | Stepper Motors | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Sensor Manufacturing | Temperature Sensors | Temperature Transmitters | Thermal Imagers | Thermistors | Thermocouple | Thermocouple Wire | Thermowell | Ultrasonic Flow Meters | Vortex Flow Meter | Wireless Sensors
trodeks.comtrodeks.com - فقخیثنس.زخئ - صصص.فقخیثنس.زخئ