PLACE ORDER - Highest Accuracy in Class to 0.015% of Reading
- Measure and Simulate T/Cs (13 Types), RTDs (13 Types), Ω, Current, Voltage, Frequency and Pressure; Source Pulse Trains
- Pressure Module Communication Port Compatible With trodeks Pressure Modules
- Direct Entry of Custom RTD Coefficients (R0, A, B, C)
- All Simulate Modes Can be Programmed With Dedicated Setpoints to Speed Calibration and Linearity Tests
- Store Up to 21 Data Points Per Instrument, and Up to 50 Instruments in Non-Volatile Memory
- Test for Pass/Fail Criteria
- Capture Both as Found and as Left Data
- Software is Included
- Protective Rubber Boot Standard
Description
Description
The CL310 documenting multi-function calibratordelivers a feature set unmatched in high accuracy,hand-held calibrators in its price range. The CL310delivers functions and accuracy associated with fixedinstallation, laboratory instruments, and has everythingneeded for virtually any calibration task. What makesthis versatile calibrator best in class is the ability tofully document any calibration easily while performingthe normal job. Software is included. Some functionswill require a Microsoft Excel-compatibility.
CL310 can also measure and source thermocouples,RTDs, current, voltage, frequency, and it can sourcepulse trains. It has a communications port for pressuremodules and an isolated mA/V readback circuit. Arrowkeys, direct numeric keypad entry, and three softwaredrivenfunction buttons combine with a large, backlit,menu-driven graphics display to provide a highlyintuitive yet powerful interface. A built-in 250 Ω resistorfor Hart® compatibility; compatibility with smarttransmitters and PLCs, full fuseless protection, and aserial communications port for control using ASCIIcommands are additional features that makethe CL310 indispensable for calibration tasks. Thisproduct is battery operated.
Note: Use only AA size alkaline batteries (not to be used with AC adapter or battery charger) or optional rechargeable batteries.
Warning
This product has non-rechargeable alkaline batteries installed.Prior to connecting any AC adapter or battery charger, thesebatteries must be removed and/or replaced with rechargeablebatteries such as Nickel Cadmium or Nickel Metal Hydride types.Failure to remove the batteries will result in damage to the calibratorand voids the warranty.
Measuring PressureWith a PCL-PMA pressure module adaptor, the CL310will work with all trodeks PCL-PM pressure modules.(For information on these see specifications, see the ).
SPECIFICATIONS (23 ±5°C unless otherwise noted)
Voltage:
Source: 0.000 to 20.000 Vdc
Read:
Isolated: 0.000 to 30.000 Vdc
Non-Isolated: 0.000 to 20.000 Vdc
Thermocouple mV:
Read/Source: -10.000 to 75.000 mV
Current (mA):
Source: 0.000 to 24.000 mA
Read:
Isolated: 0.000 to 24.000 mA
Non-Isolated: 0.000 to 24.000 mA
Frequency (1 to 20V Selectable Amplitude):
CPM Source/Read: 2.0 to 600.0 cpm
Hz Source/Read: 1.0 to 1000.0 Hz
kHz Source/Read: 1.0 to 10.00 kHz
Pulse (Source Only 1 to 20V; Selectable Amplitude):
Pulses: 1 to 30,000; 2 cpm to 10 kHz
Ohms:
Source: 5.0 to 4000.0Ω
Read: 0.00 to 4000.0Ω
Thermocouple Range Read and Source:
Type J: -200.0 to 1200.0°C (-328 to 2192°F)
Type K: -200.0 to 1370.0°C (-328 to 2498°F)
Type T: -200.0 to 400.0°C (-328 to 752°F)
Type E: -200.0 to 950.0°C (-328 to 1742°F)
Type R: -20.0 to 1750.0°C (-4 to 3182°F)
Type S: -20.0 to 1750.0°C (-4 to 3182°F)
Type B: 600.0 to 1800.0°C (1112 to 3272°F)
Type C: 0 to 2316.0°C (32 to 4201°F)
Type XK: -200.0 to 800.0°C (-328 to 1472°F)
Type BP: 0 to 2500.0°C (32 to 4532°F)
Type L: -200.0 to 900.0°C (-328 to 1652°F)
Type U: -200.0 to 400.0°C (-328 to 752°F)
Type N: -200.0 to 1300.0°C (-328 to 2372°F)
RTD Range Read and Source:
Ni120 (672): -80.0 to 260.0°C (-112 to 500°F)
Pt100 (385): -200.0 to 800.0°C (-328 to 1472°F)
Pt100 (3926): -200.0 to 630.0°C (-328 to 1166°F)
Pt100 (3916): -200.0 to 630.0°C (-328 to 1166°F)
Pt200 (385): -200.0 to 630.0°C (-328 to 1166°F)
Pt500 (385): -200.0 to 630.0°C (-328 to 1166°F)
Pt1000 (385): -200.0 to 630.0°C (-328 to 1166°F)
Cu10: -100.0 to 260.0°C (-148 to 500°F)
YSI400: 15.00 to 50.00°C (59 to 122°F)
Cu50: -180.0 to 200.0°C (-292 to 392°F)
Cu100: -180.0 to 200.0°C (-292 to 392°F)
Pt385-10: -200.0 to 800.0°C (-328 to 1472°F)
Pt385-50: -200.0 to 800.0°C (-328 to 1472°F)
Accuracy
Voltage: ±0.015% of reading, ±2 mV
Thermocouple: mV ±0.02% of reading, ±10 µV
Thermocouple Errors (Typical at 100°C) (In °C; Add 0.2 for Cold-Junction Compensation Error)
Type J: 0.2°C (0.4°F) | | Type K: 0.3°C (0.5°F) |
Type T: 0.2°C (0.4°F) | | Type B: 1.2°C (2.2°F) |
Type S: 1.2°C (2.2°F) | | Type XK: 0.2°C (0.4°F) |
Type C: 0.6°C (1.6°F) | | Type L: 0.2°C (0.4°F) |
Type BP: 0.9°C (34°F) | | Type N: 0.4°C (0.7°F) |
Type U: 0.25°C (0.5°F) | | |
RTD Read/Source:
Ni120 (672): 0.06°C (0.11°F) | | Pt100 (385): 0.13°C (0.23°F) |
Pt100 (3926): 0.13°C (0.23°F) | | Pt100 (3916): 0.13°C (0.23°F) |
Pt200 (385): 0.45°C (0.81°F) | | Pt500 (385): 0.21°C (0.38°F) |
Pt1000 (385): 0.14°C (0.75°F) | | Cu10: 0.82°C (1.48°F) |
YSI400: 0.05°C (0.09°F) | | Cu50: 0.20°C (0.36°F) |
Cu100: 0.13°C (0.23°F) | | Pt385-10: 0.84°C (2.16°F) |
Pt385-50: 0.21°C (0.38°F) | | |
Read/Source:
Current (mA): ±0.015% of reading, ±2 µA/±0.015% of reading, ±2 µA
CPM: ±0.05% of reading, ±0.1
Hz: ±0.05% of reading, ±0.1 Hz
kHz: ±0.05% of reading, ±0.01 kHz/±0.125% of reading
Ohms (Works with All Pulsed Transmitters Down to 5 ms):
5 to 400 Ohms Range: ±0.015% of reading ±0.03Ω/ ±0.015% of reading ±0.1Ω
400 to 1500 Ohms Range: ±0.015% of reading ±0.3Ω
1500 to 4000 Ohms Range: ±0.015% of reading ±0.3Ω
Environmental
Operating Temperature: -10 to 50°C (14 to 122°F)
Storage Temperature: -20 to 70°C(-4 to 158°F)
Stability: ±0.005% of reading/°C (outside of 23°C ±5°C)
Power Requirement: 6 Vdc
Batteries: 4 "AA" alkaline (included) or optional rechargeable
Mechanical
Note: Use only AA size alkaline batteries or optional rechargeablebatteries.
Warning
This product has non-rechargeable alkaline batteries installed.Prior to connecting any AC adapter or battery charger, thesebatteries must be removed and/or replaced with rechargeablebatteries such as Nickel Cadmium or Nickel Metal Hydride types.Failure to remove the batteries will result in damage to the calibratorand voids the warranty.
Dimensions: 220.9 H x 106.6 W x 58.4 mm D (8.7 x 4.2 x 2.3")
Weight: 863 g (30.5 oz) Anemometer | Automation | Accelerometers | Calibrator | Cartridge Heaters | Chart Recorders | Cryogenics | Custom Pressure Transducers | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Fiber Optic Temperature Measurement | Flexible Heaters | Flow Meters | Glass Bulb Thermometers | Grippers | Heaters | Humidity Measurement | Integrated Circuit Sensors | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells | M12 Temperature Connectors | Magnetic Flow Meter | Panel Meter | PID Controllers | pH meter | Pressure Gauges | Pressure Transducers | Pressure Transmitters | Rotameters | RTD | Remote Process Monitoring | Sanitary Sensors | Signal Conditioners | Stepper Motors | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Sensor Manufacturing | Temperature Sensors | Temperature Transmitters | Thermal Imagers | Thermistors | Thermocouple | Thermocouple Wire | Thermowell | Ultrasonic Flow Meters | Vortex Flow Meter | Wireless Sensors