Universal RTD Calibrator
CL515-PLUS
PLACE ORDER - Easy to Use
- Calibrate and Measure Most RTD Sensors
- Comes Protected With a Rugged Rubber Boot
- Calibrate Directly in Temperature (ºC or ºF)
- Compatible With All Process Instruments
Description
Description
With the CL515-PLUS you cancheck and calibrate all your RTDinstruments and measure RTDSensors. Automatic indication ofconnections on the display forsimple hookups.
Stop carrying around a decade boxand RTD resistance tables. TheCL515-PLUS works with the RTDsyou use including Platinum 100(alpha = 3850, 3902, 3926) & 1000(alpha = 3850, 3750) Ohm, Copper10 & 50 Ohm, Nickel 100 and 120Ohm. Easily set any value quickly towithin 0.1° with the adjustable digitalpotentiometer “DIAL” plus store anythree temperatures for instant recallwith the check switch.
Calibrate quickly with automaticoutput stepping, choose between2, 3, 5, 11 and 21 steps toautomatically increment the outputin 100%, 50%, 25%, 10% or 5% ofspan. Select the step time to matchyour system from 5, 6, 7, 8, 10, 15,20, 25, 30 and 60 seconds.
Carry it without worry—it comesprotected with a rubber boot andrugged, low profile switch. Easy tooperate even in the dark areas ofthe plant with the backlit display.
SPECIFICATIONS (Unless otherwise indicated all specifications are rated from a nominal 23°C, 70% RH for 1 year from calibration)
Accuracy: ±(0.015% of Reading + 0.05 Ω)
Temperature Drift: ± 0.01% of span outside of 23°C ±10°C (73°C ±18°F) Operating Temperature
Range: -25 to 60°C (-10 to 140°F)
Relative Humidity Range: 10% ≤RH ≤90% (0 to 35°C), non-condensing, 10% ≤RH ≤70% (35 to 60°C), non-condensing
Dimensions: 143 L x 76 W x 41 mmH (5.63 x 3.00 x 1.60")
Weight: 0.34 kg (12.1 oz) including boot and batteries
Power: 4 "AA" Alkaline 1.5V (LR6) (included)
Battery Life: 50 Hours low Battery low battery indication with nominal 1 hour of operation left. Protection against misconnection over-voltage protection to 60 Vdc (rated for 30 seconds)
Display: High contrast graphic liquid crystal display. LED backlighting for use in low lit areas.
READ
Excitation: Current 0.5 mA nominal
Normal Mode Rejection: 50/60 Hz, 50 dB
Common Mode Rejection: 50/60 Hz, 120 dB
SOURCE
Accuracy: From 1 to 10.2 mA external excitation Current ± (0.015% of Reading + 0.05 Ω)
Below: 1 mA of external excitation
Current: ± (0.015% of reading + 0.025 mV/mA excitation current + 0.05 Ω)
Resistance Ranges: 0.00 to 410.00, 410.1 to 4001.0 Ω
Allowable Excitation Current Range
<410 Ohms: 10.2 mA max; steady or pulsed/intermittent
410 to 4001 Ohms: 1 mA max; steady or pulsed/intermittent
Pulsed Excitation: Current compatibility DC to 0.01 second pulse width 0.025 mV Anemometer | Automation | Accelerometers | Calibrator | Cartridge Heaters | Chart Recorders | Cryogenics | Custom Pressure Transducers | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Fiber Optic Temperature Measurement | Flexible Heaters | Flow Meters | Glass Bulb Thermometers | Grippers | Heaters | Humidity Measurement | Integrated Circuit Sensors | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells | M12 Temperature Connectors | Magnetic Flow Meter | Panel Meter | PID Controllers | pH meter | Pressure Gauges | Pressure Transducers | Pressure Transmitters | Rotameters | RTD | Remote Process Monitoring | Sanitary Sensors | Signal Conditioners | Stepper Motors | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Sensor Manufacturing | Temperature Sensors | Temperature Transmitters | Thermal Imagers | Thermistors | Thermocouple | Thermocouple Wire | Thermowell | Ultrasonic Flow Meters | Vortex Flow Meter | Wireless Sensors