1-8 DIN Process Panel Meter
DP6000 Series
PLACE ORDER - Modular USB, RS232, RS485 Serial Communication Options and Relays
- 0 to 20 mA, 4 to 20 mA, 0 to 5V, 1 to 5V, and ±10V Inputs
- NEMA 4X (IP65) Front
- Universal 85 to 265 Vac or 12/24 Vdc Input Power
- Large Dual-Line 6-Character Display, 15 and 12 mm (0.60 and 0.46")
- Sunlight Readable Display Models
- Isolated 24 Vdc @ 200 mA Transmitter Power Supply Standard
- Programmable Displays and Function Keys
- 32-Point, Square Root, or Exponential Linearization
- Modbus ® RTU Communication Protocol Standard
- Free Software for Operation, Monitoring and Programming
Description
Description
The DP6000 Series meter boastsspecifications and functionalitythat clearly make it one of themost advanced process metersavailable. Its dual-line 6-digitdisplay (999,999), advancedsignal input conditioning functions,function keys, Modbus RTUserial communications, andoptional expansion modulesare only a few of the featuresfound on the DP6000. Sunlightreadable display models have anextraordinarily bright LED display.They are perfect for applicationswhere the meter is in directsunlight or in applications wherevisibility may be impaired bysmoke, fog, dust, or distance.The upper display can beprogrammed to indicate PV,maximum (peak), minimum(valley), alternating maximum/minimum, one of eight alarmset points, or Modbus input.The lower display can also beconfigured to display engineeringunits, set points, user definedlegends, or simply turned off. Theuser friendly dual-line displaymakes the DP6000 easy to setup and program. No jumpers toset for input selection. All setupand programming are done viathe front panel. Three levels ofpassword protection help maintainthe reliability of the programming.The Copy feature is used to copy(or clone) all the settings fromone DP6000 to other meters inabout 20 seconds! The Copyfunction is a standard feature onall meters. It does not require acommunications adaptor, only anoptional cable assembly.
General Specifications
Display: Both displays are 6 digits (-99999 to 999999), red LEDs with leading zero blanking
Upper Display: 15 mm (0.60") high
Lower Display: 12 mm (0.46") high
Display Intensity: 8 intensity levels
Display Update Rate: 5/second (200 ms)
Overrange: Display flashes 999999
Underrange: Display flashes -99999
Display Assignment: The upper and lower displays may be assigned to PV1, PV2, PCT (percent), max/min, alternate max and min, set points, units (lower display only), or Modbus input
Front Panel: NEMA 4X (IP65)
Programming Methods: 4 front panel buttons, digital inputs, PC and software, Modbus registers, or cloning using copy function
Noise Filter: Programmable from 2 to 199 (0 will disable filter)
Filter Bypass: Programmable from 0.1 to 99.9% of calibrated span
Recalibration: Calibrated at the factory. Recalibration is recommended at least every 12 months
Max/Min Display: Max (peak)/ min (valley) readings reached by the process are stored until reset by the user or until power to the meter is cycled
Password: 3 programmable passwords restrict modification of programmed settings; Pass 1: Allows use of function keys and digital inputs; Pass 2: Allows use of function keys, digital inputs and editing set/reset points; Pass 3: Restricts all programming, function keys, and digital inputs
Non-Volatile Memory: All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost
Power Options: 85 to 265 Vac 50/60 Hz, 90 to 265 Vdc, 20 W max, or jumper selectable 12/24 Vdc ±10%, 15 W max
Fuse (External, Required): UL recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse
Isolated Transmitter Power Supply: 24 Vdc ±5% @ 200 mA max (standard), (12/24 Vdc powered models rated @ 100 mA max); 5 or 10 Vdc @ 50 mA max, selectable with internal jumper J4
Normal Mode Rejection: Greater than 60 dB at 50/60 Hz
Isolation: 4 kV input/output-to-power line; 500 V input-to-output or output-to-P+ supply
Overvoltage Category: Installation overvoltage category II; local level with smaller transient overvoltages than installation overvoltage category III
Operating Temperature Range: -40 to 65°C (-40 to 149°F)
Storage Temperature Range: -40 to 85°C (-40 to 185°F)
Relative Humidity: 0 to 90% non-condensing
Connections: Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adaptors
Enclosure: 1/8 DIN, high impact plastic, UL 94V-0, color: black
Mounting: 1/8 DIN panel cutout required: 92 x 45 mm (3.622 x 1.772"); two panel mounting bracket assemblies are provided
Tightening Torque: Screw terminal connectors: 5 lb-in (0.56 Nm)
Overall Dimensions: 119 W x 62 H x 143 mm D (4.68 x 2.45 x 5.64")
Weight: 269 g (9.5 oz) Anemometer | Automation | Accelerometers | Calibrator | Cartridge Heaters | Chart Recorders | Cryogenics | Custom Pressure Transducers | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Fiber Optic Temperature Measurement | Flexible Heaters | Flow Meters | Glass Bulb Thermometers | Grippers | Heaters | Humidity Measurement | Integrated Circuit Sensors | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells | M12 Temperature Connectors | Magnetic Flow Meter | Panel Meter | PID Controllers | pH meter | Pressure Gauges | Pressure Transducers | Pressure Transmitters | Rotameters | RTD | Remote Process Monitoring | Sanitary Sensors | Signal Conditioners | Stepper Motors | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Sensor Manufacturing | Temperature Sensors | Temperature Transmitters | Thermal Imagers | Thermistors | Thermocouple | Thermocouple Wire | Thermowell | Ultrasonic Flow Meters | Vortex Flow Meter | Wireless Sensors