Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
1-16 DIN Limit Controller
CN6221 Series
PLACE ORDER - Dual Display
- Universal Input
- High or Low Limit
- Digital Input for Remote Reset
- RS485 Communications (Optional)
- Alarms (Optional)
- Retransmission Output (Optional)
Description
Description
The CN6221 Series is an FMapproved limit controller that can beconfigured either as a high limit oras a low limit controller. The CN6221features universal input, Optional 2 alarmoutputs, Optional retransmission output, atimer to count the total time thesetpoint is exceeded, and a registerto retain the maximum. The RS485communication interface is availableas an option.
Input Type | Range (°C) | Range (°F) |
Thermocouple | K | -270 to 1370 | -300 to 2500 |
0 to 600 | 32 to 999.9 |
0 to 400 | 32 to 750 |
-199.9 to 200 | -300 to 400 |
J | -199.9 to 999.9 | -300 to 2100 |
T | -199.9 to 400 | -300 to 750 |
E | -199.9 to 999.9 | -300 to 1800 |
R | 0 to 1700 | 32 to 3100 |
S | 0 to 1700 | 32 to 3100 |
B | 0 to 1800 | 32 to 3200 |
N | -200 to 1300 | -300 to 2400 |
L | -199.9 to 900 | -300 to 1600 |
U | -199.9 to 400 | -300 to 750 |
Platinel 2 | 0 to 1390 | 32 to 2500 |
RTD | Pt100 | -199.9 to 850 | -199.9 to 999.9 |
0 to 400 | 32 to 750 |
-199.9 to 200 | -300 to 400 |
-19.9 to 99.9 | -199.9 to 999.9 |
JPt100 | -199.9 to 500 | – |
DC Voltage | 0 to 100 mV | 0 to 100 | – |
0 to 5 V | 0 to 5 | – |
1 to 5 V | 1 to 5 | – |
0 to 10 V | 0 to 10 | – |
SPECIFICATIONS
Power Supply
Voltage: 100 to 240 Vac (±10%),
Frequency: 50 or 60 Hz
Maximum Power Consumption: 8 Va max (4 W max)
Memory: Non-volatile memory
Withstanding Voltage (Between Primary and Secondary Terminals): 1500 Vac for 1 min (see Note1)
Insulation Resistance (Between Primary and Secondary Terminals): 20 MΩ or more at 500 Vdc (see Note 1)
Note 1: The primary terminals are the power supply terminals and relay output terminals.The secondary terminals are the analog input and output terminals, the voltage pulse output terminals, and the contact input terminals.
Contact Input
Function: Resetting "exceeded status"
Input: 1 point
Type: Non-voltage contact or transistor contact
Contact Capacity: At least 12 V/10 mA
On/Off Judgment: On state for 1 kΩ or less; off state for 20 kΩ or greater
Measured Value (PV)
Input: 1 point
Type: Universal
Accuracy (At 23 ±2°C Ambient Temperature):
Thermocouple: ±2°C ±1digit
At -200 to -100°C: ±4°C
At -100 to 0°C: ±3°C
Types R and S: ±5°C [±9°C for 0 to 500°C (X to X°F)]
Type B: ±9°C (accuracy is not guaranteed for 0 to 400°C)
RTD: ±1°C ±1digit
Voltage (mV, V): ±0.3% ±1digit
Sampling Period for Measured Value Input: 500 ms
Burn-Out Detection: Functions for thermocouple or RTD input (burn-out upscale only; cannot be switched off)
Input Resistance: 1 MΩ or greater for thermocouple or DC mV inputs; approx 1 MΩ for DC V input
Maximum Allowable Signal Source Resistance: 250 Ω for thermocouple or DC mV input; 2 kΩ for DC V input
Maximum Allowable Wiring Resistance for RTD Input: 10 Ω/wire (resistance values of 3 wires must be the same)
Allowable Input Voltage: ±10 Vdc for thermocouple or DC mV input; ±20 Vdc for DC V input
Noise Rejection Ratio:
Normal Mode Noise: Minimum 40 dB (50/60 Hz)
Common Mode Noise: Minimum 120 dB (90 dB for DC V input)
Reference Juction Error Compensation: ±1.5°C (at 15 to 35°C), ±2.0°C (at 0 to 50°C)
The reference junction compensation cannot be switched off
Applicable Standards: RTD, Thermocouple, JIS/IEC/DIN (ITS90) Anemometer | Automation | Accelerometers | Calibrator | Cartridge Heaters | Chart Recorders | Cryogenics | Custom Pressure Transducers | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Fiber Optic Temperature Measurement | Flexible Heaters | Flow Meters | Glass Bulb Thermometers | Grippers | Heaters | Humidity Measurement | Integrated Circuit Sensors | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells | M12 Temperature Connectors | Magnetic Flow Meter | Panel Meter | PID Controllers | pH meter | Pressure Gauges | Pressure Transducers | Pressure Transmitters | Rotameters | RTD | Remote Process Monitoring | Sanitary Sensors | Signal Conditioners | Stepper Motors | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Sensor Manufacturing | Temperature Sensors | Temperature Transmitters | Thermal Imagers | Thermistors | Thermocouple | Thermocouple Wire | Thermowell | Ultrasonic Flow Meters | Vortex Flow Meter | Wireless Sensors
trodeks.comtrodeks.com - فقخیثنس.زخئ - صصص.فقخیثنس.زخئ