Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
Hybrid Chart Recorder- 250 mm (10")
RD5100 Series
PLACE ORDER - High Speed Scanning at 36 Points/Sec and High-Speed Recording
- High Accuracy of 0.05%
- Various Industrial Values Can be Measured at the Same Time with Selectable Ranges
- Superior Ease of Operation
- Engineering Port is Provided (USB)
- Anti-Noise Countermeasures
- Communication Interfaces are Available
- Recording and Calculation of Data Communication Input
Description
Description
RD5100 series chart recorders are250 mm (10") hybrid recorders withmulti-range input. Innovative designhigh performance recorder provideshigh accuracy, ±0.05%; high speedscanning, 0.1 second for 36 pointsand high speed recording, 1 line in3 seconds. Simple operational keysand PC setting functions drasticallyimproved usability of recordingsystem.
SPECIFICATIONS
Input
Number of Measuring Points: 12, 24 and 36 points
Input Types: Universal (refer to the table of inputs)
Range Setting: Input type and range are set with front keys
Scale Setting: The minimum and maximum values and unit are set for each point with front keys
Setting Range: -30,000 to 30,000
Decimal Points: Optional setting
Indication Accuracy: Refer to the table of inputs on page S-35d
Temperature Drift: 0.1% FS/ 10°C
Measuring Period: 0.1 sec/channel
Reference Junction Compensation Accuracy:
K, E, J, T, N, Platinel II: ±0.5°C (33°F) or less [0°C (32°F) or more when measuring]
R, S, WRe5-WRe26, NiMo-Ni, U, L: ±1.0°C (34°F) or less [only when the ambient temperature is 23°C (73°F) ±5°C (41°F)]
Input Resolution: Approx. 1/40,000 (standard range conversion)
Burnout: Select with/without burnout for each input
Allowable Signal Source Resistance: Thermocouple Inputs, DC Voltage
Input (10 mV): 500Ω or less (without burnout) DC Voltage Input (Except 10 mV): 100Ω or less Resistance Thermometer Inputs: 10Ω or less/ line, three lines are common, Pt100, JPt100
Input Resistance:
Thermocouple Input, DC Voltage Input: Approx. 1MΩ
Maximum Input Applied Voltage: ±20 Vdc
Input Correction: Zero/span correction and shift correction for each channel
Maximum Common Mode Coltage: 30 Vac (support LVD)
Common Mode Rejection Ratio: 130dB
Series Mode Rejection Ratio: 50dB (only when the peak value of noise is below standard range)
Terminal Board: Detachable type, removable for wire connection
Recording Specifications
Recording System: Raster scan system, 10-color wire dot printing
Recording and Recording Color:
Analog Recording: Color can be specified for each channel as required 10 colors (red, purple-red, orange, brown, green, yellow-green, blue-green, purple, purple-blue, black) Digital Recording and Logging
Recording: Black
Message Printing: Black
List Printing: Black
Chart Paper: Fan-fold type; overall width 318 mm (12.5"), total length 20 m (65.6'); effective recording width 250 mm (10") (analog recording)
Chart Speed: 1 to 1500 mm/H [in 1 mm/H steps]
Skip Function: Analog recording, digital recording and digital display can be set independently from recording slip
Recording Compensation: Independent setting of zero spans are available
Display Specifications
Digital Display: Color LCD panel RGB (640 x 240 dot)
Display Size: 149.8 W x 57.4 mm H (5.8 W x 2.25" H)
Setting Display: Common to digital display*
Display Contents: Digital display
Channel Display: One-point/multiple points continuous/sequential indication change Display Measuring Value of
Each Channel: One-point/multiple points continuous/sequential indication change
Clock Display: Hour/Minute/ Second/Tag/Unit Chart Speed Display
Status Display:
Record On: Lights during recording; LED
Key Lock: Lights during key lock
Alarm: Lights during alarm activated; LED
Chart End: Lights just before record ending
Fail: Lights during unit abnormal time
* Sharing LED and setting display
Alarm SpecificationsAlarm Display: Occurrence CH No, data is displayed in red when alarm occurs
Alarm Types: High limit, low limit
Alarm Setting Method: Individual setting for each point four levels/ channels
Alarm Output: See option specification
Setting and Operational Specifications
Key Types, Operation:
|
|
|
Func1: Switching each function Func2: Switching each function Enter: Setting a change of parameter for each mode Menu: Specifying each setting function Esc: Used to escape in the middle of setting Used to switch channels when specifying the parameter on cursor Used to switch channels when specifying the parameter on cursor Used to move cursor to the right Used to move cursor to the left Rec: Analog recording, digital recording, printing, switching chart ON/OFF DataP: Digital recording of latest data Feed: Fast-forwarding chart paper Shift: Specifying key
| | | | . _ =: Setting characters of “. _ =” @ + -: Setting characters of “@ + -” 0 * /: Setting parameter value 0 and character of “* / ” 1ABC: Setting parameter value 1 and character of “ABC ” 2DEF: Setting parameter value 2 and character of “DEF” 3GHI: Setting parameter value 3 and character of “GHI” 4JKL: Setting parameter value 4 and character of “JKL” 5MNO: Setting parameter value 5 and character of “MNO” 6PQR: Setting parameter value 6 and character of “PQR” 7STU: Setting parameter value 7 and character of “STU” 8VWX: Setting parameter value 8 and character of “VWX” 9YZ: Setting parameter value 9 and character of “YZ”
|
Recording Operation:
Record On/Off: Recording operation ON/OFF*
Data Print: Printing measuring data*
Feed: Fast-forwarding chart paper
* Two actions are taken to operate
General Specifications
Rated Power Voltage: 100 to 240 Vac (universal power supply) 50/60Hz
Maximum Power Consumption: 100V A
Reference Operating Condition:
Ambient Temperature/Humidity Range: 21 to 25°C (70 to 77°F), 45 to 65% RH
Power Voltage: 90 to 264V
Power Frequency: 50/60Hz ±2%
Attitude: Forward/Backward/left/right within 3°
Warm-Up Time: 1 hour or longer
Normal Operating Condition:
Ambient Temperature/Humidity Range: 0 to 40°C (32 to 104°F), 20 to 80% RH
Power Voltage: 90 to 264V
Power Frequency: 50/60Hz ±2%
Attitude: Forward/backward/left/right within 3°
Transportation Condition: At the packed condition on shipment from our factory
Ambient Temperature/Humidity< Range: -20 to 60°C (-4 to 140°F), 5 to 90%RH (no dew condensation)
Vibration: 10 to 60 Hz, 4.9 m (16')/ S2 (0.5G or less)
Impact: 392 m (1.3')/S2 (approx. 40G or less)
Storage Condition:
Ambient Temperature: -20 to 60°C (-4 to 140°F), 5 to 90% RH (no dew condensation)
Working Condition:
Working Temperature Range: 0 to 40°C (32 to 104°F)
Working Humidity Range: 20 to 80% RH
Power Failure Protection: Programmed parameters stored into EEPROM memory clock circuit sustained for 5 years or longer by a lithium battery (at the operation of 8 hours or longer per day)
Insulation Resistance:
Between Primary Terminals and Protective Conductor Terminals: 20MΩ or more at 500 Vdc
Between Secondary Terminals and Protective Conductor Terminals: 20MΩ or more at 500 Vdc
Between Primary Terminals and Secondary Terminals: 20MΩ or more at 500 Vdc
Dielectric Strength:
Between Primary Terminals and Protective Conductor Terminals: 1 minute at 1500 Vac
Between Secondary Terminals and Protective Conductor Terminals: 1 minute at 500 Vac
Between Primary Terminals and Secondary Terminals: 1 minute at 1500 Vac
Note 1:
Primary Terminals: Power terminal, alarm output terminal, output relay terminal
Secondary Terminals: Measuring input terminal, communication terminal, external drive terminal
Note 2: When testing insulation resistance and dielectric strength, please short-circuit every terminals of primary and secondary terminals before the test; test without short-circuiting terminals can damage instruments
Case Assembly Material:
Door (Frame): ABS resin
Front Panel: Soda glass
Back Case: Normal steel
Color:
Door (Frame): White (equivalent to DIC546 1.2)
Front Panel: Transparent
Back Case: White (equivalent to DIC546 1.2)
Mounting: Panel mounting
Weight: About 15 kg (33 lb) (full option)
Dimensions: 400 W x 260 H x 300 mm D (15.7 W x 10.2 H x 11.8" D)
Panel Cut Dimensions: 388 x 248 mm (15.2 x 9.7")
Terminal Screws:
Measuring Input, Alarm Terminals: M3.5
Power, Protective Conductor Terminal, External Drive Terminal, Communication Terminal: M4
Chart Paper Illumination: White LED Anemometer | Automation | Accelerometers | Calibrator | Cartridge Heaters | Chart Recorders | Cryogenics | Custom Pressure Transducers | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Fiber Optic Temperature Measurement | Flexible Heaters | Flow Meters | Glass Bulb Thermometers | Grippers | Heaters | Humidity Measurement | Integrated Circuit Sensors | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells | M12 Temperature Connectors | Magnetic Flow Meter | Panel Meter | PID Controllers | pH meter | Pressure Gauges | Pressure Transducers | Pressure Transmitters | Rotameters | RTD | Remote Process Monitoring | Sanitary Sensors | Signal Conditioners | Stepper Motors | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Sensor Manufacturing | Temperature Sensors | Temperature Transmitters | Thermal Imagers | Thermistors | Thermocouple | Thermocouple Wire | Thermowell | Ultrasonic Flow Meters | Vortex Flow Meter | Wireless Sensors
trodeks.comtrodeks.com - فقخیثنس.زخئ - صصص.فقخیثنس.زخئ