Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
Product Groups
Dual Channel Autotune Temperature Controllers
TRODEKS Engineering | Thermocouples, Pressure Transducers, Flow Meters, PID Controllers
CYC325
PLACE ORDER 
  • Operates Down to 1.2 K with Appropriate Sensors
  • 2 Sensor Inputs
  • Supports Diode, RTD, and Thermocouple Sensors
  • Sensor Excitation (Current Reversal Eliminates Thermal EMF Errors for Resistance Sensors)
  • 2 Autotuning Control Loops: 25 and 2 W Max
  • Control Loop 2: Variable Vdc source from 0 to 10 V Max
  • IEEE-488 and RS232C Interfaces
 Specs
 Manuals (contact with email : [email protected])
 Print
Description

Description

The CY325 Series dual-channel temperature controlleris capable of supporting nearly any diode, RTD, orthermocouple temperature sensor. Two independentPID control loops with heater outputs of 25 and 2 Ware configured to drive either a 50 or 25 Ù load foroptimal control flexibility. Designed with ease of use,functionality, and value in mind, the CYC325 Series isideal for general-purpose laboratory and industrialtemperature measurement and control applications.

SPECIFICATIONS
Thermometry
Number of Inputs: 2
Input Configuration: Each input is factory configured for either diode/RTD or thermocouple
Isolation: Sensor inputs optically isolated from other circuits but not each other
A/D Resolution: 24-bit
Input Accuracy: Sensor dependent, refer to input specifications table
Measurement Resolution: Sensor dependent, refer to input specifications table
Max Update Rate: 10 rdg/s on each input (except 5 rdg/s on input A when configured as thermocouple)
Filter: Averages 2 to 64 input readings
Sensor Input Configuration Diode/RTD:
    Measurement Type: 4-lead differential
    Excitation: Constant current with current reversal for RTDs
    Supported Sensors: Diodes, silicon, GaAlAs; RTDs, 100 ΩPlatinum, 1000 Ω Platinum, germanium, carbon-glass, CernoxTM, and RoxTM
    Standard Curves: CY7 and CY670, PT-100, PT-1000, RX-102A, RX-202A
    Input Connector: 6-pin DIN
Thermocouple:
    Measurement: 2-lead, room temperature, compensated
    Excitation: N/A
    Supported Sensors: Most thermocouple types
    Standard Curves: Type E, Type K, TypeT, AuFe 0.07% vs Cr, AuFe 0.03% vs Cr
    Input Connector: Ceramic isothermal block

Control
Control Loops: 2
Control Type: Closed loop digital PID with manual heater output or open loop
Tuning: Autotune (1 loop at a time), PID, PID zones
Control Stability: Sensor dependent, see input specification table
PID Control Settings:
    Proportional (Gain): 0 to 1000 with 0.1 setting resolution
    Integral (Reset): 1 to 1000 (1000/s) with 0.1 setting resolution
    Derivative (Rate): 1 to 200% with 1% resolution
Manual Output: 0 to 100% with 0.01% setting resolution
Zone Control: 10 temperature zones with P, I, D, manual heater out, and heater range
Setpoint Ramping: 0.1 K/min to 100 K/min
Safety Limits: Curve temperature, power up heater off, short circuit protection
Front Panel:
    Display: 2-line, 20-character, liquid crystal display with 5.5 mm (0.216") character height
    Number of Reading Displays: 1 to 4
    Display Units: K, °C, V, mV,
Reading Source: Temperature, sensor units
    Display Update Rate: 2 rdg/s
    Temp Display Resolution: 0.001° from 0 to 99.999°, 0.01° from 100 to 999.99°, 0.1° above 1000°
    Sensor Units Display Resolution: Sensor dependent; to 5 digits
    Other Displays: Setpoint, heater range, and heater output; user selected
Setpoint Setting Resolution: Same as display resolution (actual resolution is sensor dependent)
Heater Output Display: Numeric display in percent of full scale for power or current
Heater Output Resolution: 1%
Display Annunciators: Control input, remote, autotune
Keypad: 20-key membrane, numeric and specific functions
Front Panel Features: Front panel curve entry, keypad lock-out

Interface
IEEE-488 Interface Features: SH1, AH1, T5, L4, SR1, RL1, PP0, DC1, DT0, C0, E1
Reading Rate: To 10 rdg/s on each input
Software Support: LabVIEWTM driver; consult factory for availability
Serial Interface:
    Electrical Format: RS232C
    Baud Rates: 9600, 19200, 38400, 57600
Connector: 9-pin D-style, DTE configuration
Reading Rate: To 10 rdg/s, each input

General
Ambient Temperature: 15 to 35 °C (59 to 95ºF) at rated accuracy, 5 to 40 °C (41 to 104ºF) at reduced accuracy
Power Requirement: Standard 120 Vac, optional 240 Vac, 6%, -10%, 50 or 60 Hz, 85 VA
Dimensions: 89 H x 216 W x 368 mm D (3.5 x 8.5 x 14.5"), half rack
Weight: 4.00 kg (8.82 lb)
Approval: CE mark

Input Specifications
 Sensor Temp CoefficientInput RangeExcitation Current Display Resolution Measurement Resolution Electronic Accuracy (at 25°C) Electronic Control Stability1
Diode Negative 0 to 2.5 V 10 µA
±0.05%2,3
100 µV 0.4 µV ±80 µV
±0.005%
of rdg
±20 µV
Diode Negative 0 to 7.5 V 10 µA
±0.05%2,3
100 µV 10 µV ±80 µV
±0.001%
of rdg
±40 µV
PTC RTD Positive 0 to 500ø 1 mA4 10 mø 2 mø ±0.004ø
±0.01%
of rdg
±4 mø
PTC RTD Positive 0 to 5000ø 1 mA4 100 mø 20 mø ±0.004ø
±0.02%
of rdg
±40 mø
NTC RTD Negative 0 to 7500ø 10 µA ±0.05% 100 mø 40 mø ±0.1ø
±0.04%
of rdg
±80 mø
Thermocouple Positive ±25 mV N/A 1 µV 0.4 µV ±1 µV
±0.05%
of rdg5
±0.8 µV
Thermocouple Positive ±50 mV NA 1 µV 20 µV ±1 µV
±0.05%
of rdg5
±0.8 µV
1 Control stability of the electronics only, in ideal thermal system
2 Current source error has negligible effect on measurement accuracy
3 Diode input excitation can be set to 1 mA
4 Current source error is removed during calibration
5 Accuracy specification does not include errors from room temperature compensation
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors