Ultra High Stability Thin Film Differential Pressure Transducer
PX1006
PLACE ORDER - High Accuracy High Stability Wet/Dry Differential Pressure
- All Stainless Steel Body for Aerospace or Harsh Industrial Environments
- High Overpressure Capability
- Broad Compensated Temperature Range
- Shock and Vibration Resistant
- NIST
Description
Description
The PX1006 Series wet-dry, differential pressure transducers are high stability unidirection differential pressure transducers utilizing a sputtered strain gage assembly. The sputtering method produces an ultra stable high temperature sensor that can withstand high shockThe PX1006 wet/dry differentialpressure transducers are highstabilityaerospace units that usea sputtered strain gage assembly.The sputtering method produces anultra-stable high-temperature sensorthat can withstand high shock andvibration environments. The wetchamber is all stainless steel and iscompatible with most industrialfluids. The reference chamber islimited to dry, non-corrosive, nonconductivefluids and gases.
SPECIFICATIONS
mV/V Output
ELECTRICAL
Excitation: 5 Vdc
Output: 15 mV nominal, 13 mV minimum
Bridge Resistance: 350 Ω nominal
Zero Balance: 0 mV ±2% FSO
Input Resistance: 400 Ω nominal
Output Resistance: 400 Ω nominal
PERFORMANCE
Accuracy: ±0.25% FSO linearity, hysteresis and repeatability combined
Hysteresis: <0.1% FSO
Repeatability: <0.05% FSO Zero Shift with Line Pressure:
Line Pressure <3 psia: <1.5%
Line Pressure 3 to 15 psia: <0.25%
Line Pressure >15 psia: <2.5% Sensitivity Shift with Line Pressure: <0.5% per 100 psi
ENVIRONMENTAL
Operating Temp Range: -54 to 149°C (-65 to 300°F)
Compensated Temp Range: -54 to 121°C (-65 to 250°F)
Thermal Effects:
Zero: ±0.009% FSO/¨¬C (±0.005% FSO/°F)
Span: ±0.009% rdg/¨¬C (±0.005% rdg/°F)
Full Scale Output Stability: Less than 0.05% FSO for 2 hr at room temperature. Less than 0.10% FSO for 2 hr at 121°C (250°F).
Zero Stability: Less than 0.05% FSO for 2 hr at room temperature. Less than 0.10% FSO for 2 hr at 121°C (250°F).
PRESSURE
Ranges psid: 15, 25, 50, 100, 300, 500, 1000, 2000, 2500, 5000
Safe Overpressure: 200% rated pressure or 15,000 psi, whichever is less
Burst Pressure: 300% rated pressure or 20,000 psi, whichever is less Reference Chamber Pressure Range: 0 to 400 psi
MECHANICAL
Media Compatibility:
Wet Connection: 17-4 PH stainless steel
Dry Connection: Clean, dry, non-corrosive, non-conductive fluids
Natural Frequency: 50,000 Hz @ 5000 psi decreasing logarithmically to 5000 Hz @ 15 psi
Shock: 100 g half-sine wave for an 11 ms duration
Vibration: 35 g peak sinusoidal vibration from 10 Hz to 2 kHz limited to 1.2" D.A.
Pressure Port: MS33656-4 (7.16-20)
Electrical Connection: PTIH-10-6P (or equal)
Mating Connector: PT06F-10-6S (not included)
Weight: 142 g (5 oz) maximum Anemometer | Automation | Accelerometers | Calibrator | Cartridge Heaters | Chart Recorders | Cryogenics | Custom Pressure Transducers | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Fiber Optic Temperature Measurement | Flexible Heaters | Flow Meters | Glass Bulb Thermometers | Grippers | Heaters | Humidity Measurement | Integrated Circuit Sensors | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells | M12 Temperature Connectors | Magnetic Flow Meter | Panel Meter | PID Controllers | pH meter | Pressure Gauges | Pressure Transducers | Pressure Transmitters | Rotameters | RTD | Remote Process Monitoring | Sanitary Sensors | Signal Conditioners | Stepper Motors | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Sensor Manufacturing | Temperature Sensors | Temperature Transmitters | Thermal Imagers | Thermistors | Thermocouple | Thermocouple Wire | Thermowell | Ultrasonic Flow Meters | Vortex Flow Meter | Wireless Sensors