Sputtered Gauge Marine Pressure Transducers with Amplifier-Regulator
TRODEKS Engineering | Thermocouples, Pressure Transducers, Flow Meters, PID Controllers
6SE01079 Series
PLACE ORDER 
  • High Accuracy
  • Rugged Sputtered Strain Gauge Design
  • All Stainless Steel Construction
  • Isolated 0 to 5 VDC Output
  • Internal Shunt Resistor to Simulate Transducer Output
  • Proven Performance in Extreme Applications
 Specs
 Manuals (contact with email : [email protected])
 Print
Description

Description

SPECIFICATIONS
Recommended Excitation: 28 ±4 VDC
Rated Output (RO): 5 VDC ±0.10% (±10% Adjustable) Short Circuit Protected
Zero Balance (% RO): 0 VDC ±10% Adj. (Min.)
Temperature Effect on Zero Balance (% RO): 0.0015/°F (0.0027%/°C)
Temperature Effect on Output (% Reading): 0.0020/°F (0.0036/°C)
Compensated Temperature Range: 0 to 150°F (-18 to 66°C)
Safe Over Temperature Range: -65 to 200°F (-54 to 93°C)
Safe Overpressure Range (%RO): 150% RO (Max.)
Ultimate Overpressure Range (%RO)
5 to 5000 psi: 300% RO (Max.) (Diaphragm shall not rupture)
Combined Effects Non-Linearity, Hysteresis and Repeatability: 0.15% (Typ.), 0.25% RO (Max.)
Vibration Limit (5-2000 Hz): 0.04% RO/G (Max.)
Thermal Zero Stability: 0.15% RO (Max)
Thermal Sensitivity Stability: 0.10% RO (Max.)
Total Error Band (RSS): Root Sum Square (RSS) addition of errors due to non-linearity,hysteresis, non-repeatability (BSL) zero balance
shift (±0.003% RO/°F Nominal) and rated output
shift (±0.003% RO/°F Nominal). Shall not exceed
0.50% RO referenced at +75°F (24°C).
Part Number Instrument Range Units Accuracy
6SE01079-1 0-5 PSIG 0.25%
6SE01079-2 0-10 PSIG 0.25%
6SE01079-3 0-20 PSIG 0.25%
6SE01079-4 0-50 PSIG 0.25%
6SE01079-5 0-100 PSIG 0.25%
6SE01079-6 0-150 PSIG 0.25%
6SE01079-7 0-200 PSIG 0.25%
6SE01079-8 0-500 PSIG 0.25%
6SE01079-9 0-1000 PSIG 0.25%
6SE01079-10 0-1500 PSIG 0.25%
6SE01079-11 0-2000 PSIG 0.25%
6SE01079-12 0-5000 PSIG 0.25%
6SE01079-13 0-50 IN.HgG 0.25%
6SE01079-14 0-100 IN.HgG 0.25%
6SE01079-15 0-200 IN.HgG 0.25%
6SE01079-16 0-500 IN.HgG 0.25%
6SE01079-17 0-1000 IN.HgG 0.25%
6SE01079-18 0-20 PSIA 0.25%
6SE01079-19 0-50 IN.H2OG 0.25%
6SE01079-20 0-300 PSIG 0.25%
6SE01079-21 0-600 IN.HgG 0.25%
6SE01079-22 0-50 IN.HgA 0.25%
6SE01079-23 0-100 IN.HgA 0.25%

DIMENSIONS: IN (MM)
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors