True RMS AC Voltmeter- AmmeterIndicator-Controller1-8 DIN
DP2000-CDFG Series
PLACE ORDER - ±1999 or ±9999 Count Display Span
- 100 mV to 650 V Ranges
- 2 µA to 1 A Ranges
- Special Scaling for 5 A Current Transformer
- 1mV or 0.1 mV/Count Analog Output
- Front-Panel Accessible Adjustments
- LED or LCD Display
- Display Hold and Test
- 1/8 DIN Case
Description
Description
The DP2000/DP9000 AC AVG voltmeter and ammeteruse a precision op-amp rectifier circuit to provide aneconomical AC-average meter, which is calibrated todisplay the true-RMS value of sinusoidal signals.
The AC RMS voltmeter and ammeter use an integratedcircuit that computes the true-root-mean-square valueof complex waveforms.
Screw-terminals are provided for AC or DC coupling.AC coupling allows the measurement of the ACcomponent or ripple from a signal with both AC and DCcomponents. DC coupling allows the measurement oftrue-RMS, including both DC and AC components.
The signal conditioner provides six current ranges, asdetermined by an internal shunt resistor. In addition,there is a special 5 A range, which allows directconnection to a current transformer (CT) with 5 Asecondary, without need for a stepdown transformer.Proper scaling can be for any primary current.
An 1/8 DIN case houses each meter. Choose anycombination of display type (LED or LCD), operatingpower, input type and range, analog output, and digitalor control outputs.
SPECIFICATIONS
Conversion
Technique: Auto-zero, dual slope, average value
Signal Integration Period: 100 ms, nominal
Reading Rate: 2.5/s, nominal
Display
LED: Red, 14.2 mm (0.56"), 7-segment
LCD: 12.7 mm (0.50"), 7-segment
Power
AC Models: 120, 240 or 24 Vac 10%/ -15%; 49 to 440 Hz
DC Models: 5 Vdc ±5%, 9 to 32 Vdc or 26 to 56 Vdc isolated to 300 Vp
Common Mode
Voltage: 1500 Vp test (354 Vp per IEC spacing)
Rejection (DC to 60 Hz): 120 dB
Environmental
Operating Temperature: 0 to 60°C (32 to 140°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Humidity: 95% RH, non-condensing @ 40°C (104°F)
Accuracy @ 25°C (AC)
Maximum Error: ±0.25% of rdg ± 10 counts
Span Tempco: ±0.01% of reading/°C (AC)
Step Response: 1 s to 99.9% of span
Frequency Range for Rated Accuracy: 47 to 1000 Hz
Warmup to Rated Accuracy: 30 min
Accuracy @ 25°C (RMS) (1% to 100% of Full Scale)
Maximum Error, AC Coupling: ±0.25% of reading, ±1 ct (DP2), ±10 cts (DP9), 47 Hz to 1 kHz
Maximum Error, DC Coupling: ±0.25% of reading, ±1 ct (DP2), ±10 cts (DP9), 9 Hz to 1 kH
Span Tempco: ±0.03% of reading/°C (typical)
Zero Tempco: 0.15 mV/°C (typical)
Step Response: 1 sec to 99.9% of span
Warmup to Rated Accuracy: 30 min
Mechanical
Bezel: 96 W x 48 H x 8 mm D (3.78 x 1.89 x 0.31")
Depth Behind Bezel: 139.8 mm (5.50")
Panel Cutout: 92 W x 45 mm H (3.62 x 1.77")
Weight: 17 oz (480 g)
Case Material: 94V-0 UL-rated polycarbonate Anemometer | Automation | Accelerometers | Calibrator | Cartridge Heaters | Chart Recorders | Cryogenics | Custom Pressure Transducers | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Fiber Optic Temperature Measurement | Flexible Heaters | Flow Meters | Glass Bulb Thermometers | Grippers | Heaters | Humidity Measurement | Integrated Circuit Sensors | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells | M12 Temperature Connectors | Magnetic Flow Meter | Panel Meter | PID Controllers | pH meter | Pressure Gauges | Pressure Transducers | Pressure Transmitters | Rotameters | RTD | Remote Process Monitoring | Sanitary Sensors | Signal Conditioners | Stepper Motors | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Sensor Manufacturing | Temperature Sensors | Temperature Transmitters | Thermal Imagers | Thermistors | Thermocouple | Thermocouple Wire | Thermowell | Ultrasonic Flow Meters | Vortex Flow Meter | Wireless Sensors