Strain-Microvoltmeter Indicator Controller1-8 Din
TRODEKS Engineering | Thermocouples, Pressure Transducers, Flow Meters, PID Controllers
DP2000-S Series
PLACE ORDER 
  • Adjustable 1 to 10 Vdc Bridge Excitation Supply
  • ±1999 or ±9999 Count Display Span
  • Seven Overlapping Gain Ranges
  • Front-Panel Accessible Zero and Span Adjustments
  • Resolution Down to 1 or 2 µV/Count
  • Strain-Gauge Sensitivity Down to 0.20 mV/V
  • Ratiometric Measurement
  • 1 or 0.2 mV/Count Analog Output
  • LED or LCD Display
  • Automatic Polarity
  • Display Hold and Test
  • Screw-Terminal Barrier Strip
 Manuals (contact with email : [email protected])
 Print
Description

Description

Starting from Oct 1st 2017, DP2000/9000 Series will be discontinued. As a possible substitute, please check out the or for details.

The DP2000/9000-S is a meter/controller for use withpressure transducers and load cells which requirebridge excitation and preamplification of microvoltsignals. Deadload and tare adjustments make itsuitable for weighing applications. Like process meters,it provides zero and span adjustments for directreadout in engineering units. It can also be used as amicrovoltmeter with differential input. A universal1/8 DIN case houses each meter. Choose anycombination of display type (LED or LCD), operatingpower, input type and range, analog output, and digital orcontrol outputs.

Excitation Supply and Preamplifier
The DP2000/9000-S provides a constant-voltageexcitation supply, which is adjustable from 1 to 10V andcan drive up to 30 mA. It also provides a high-impedancepreamplifier, which is continuously adjustable so thatsignal levels from ±2.0 to ±500 mV can produce the fullscaledisplay of ±1999 or ±9999 counts. At 10V excitationand maximum gain, full-scale readout can be obtainedwith strain-gauge sensitivity as low as 0.20 mV/V. Anactive filter is provided for noise reduction.

Bridge Connection
Bridges can be connected by 4 or 6 wires. In 6-wireconnection, two lines sense the voltage applied to thebridge and compensate for lead resistance.

Resolution and Accuracy
Resolution for DP2000-S is one part in ±1999 counts,or 0.05% of full scale. Resolution for DP9000-S is onepart in ±9999 counts, or 0.01% of full scale. Accuracyis 99.9% of reading. The measurement is ratiometricto reduce errors due to temperature and power-linevariations. The same internal reference controls themeter gain and the excitation level.

SPECIFICATIONS
Gain Adjustment: Seven overlapping ranges with fine adjustment
Input Configuration: Differential, ratiometric
Zero Adjustment: ±225 µV/volt of excitation
Span Adjustment: 1 to 2.47 of preamp gain
Bias Current: 11 nA typ, 22 nA max
Noise Rejection
CMR, SIG GND to SIG LO: 80 dB, DC to 60 Hz
CMV, SIG GND to SIG LO: ±1 V, DC to 60 Hz
CMR, SIG GND to PWR GND: 120 dB
CMV, SIG GND to PWR GND: 1500 Vp per HV test, 354 Vp per IEC spacing
Accuracy at 25 °C
Error, Maximum ±0.05% of reading ±1 count (DP2); ±0.05% of reading ±2 counts (DP9)
Span Tempco: ±0.01% of reading/ °C
Zero Drift, Maximum: ±0.3 µV/ °C
Offset Drift, Maximum: ±(0.01% offset V ±0.01% FS V)/ °C
Step Response: 1 s to 99.9% of span
Warmup to Rated Accuracy: 30 min (DP2); 60 min (DP9)
Excitation
Configuration: Constant-voltage
Voltage Sense: Internal or remote
Voltage Range: Adjustable from 1 to 10V
Load Current, Maximum: 30 mA Conversion
Technique: Auto-zero, dual slope, average value
Signal Integration Period: 100 ms, nominal
Reading Rate: 2.5/s, nominal
Display
LED: Red, 14.2 mm (0.56"), 7-segment
LCD: 12.7 mm (0.50"), 7-segment
Power
AC Models: 120, 240 or 24 Vac +10%/-15%, 49 to 440 Hz
DC Models: 9 to 32 Vdc, isolated to 300 Vp; 26 to 56 Vdc, isolated to 300 Vp; 5 Vdc ±5%, non-isolated
Common Mode
Rejection: 120 dB
Environmental
Operating Temperature: 0 to 60 °C (32 to 140°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Humidity: 95% RH, non-condensing @ 40°C (104°F)
Mechanical
Bezel: 96 W x 48 H x 8 mm D (3.78 x 1.89 x 0.31")
Depth Behind Bezel: 139.8 mm (5.50")
Panel Cutout: 92 W x 45 mm H (3.62 x 1.77")
Weight: 17 oz (480 g)
Case Material: 94V-0 UL-rated polycarbonate
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors