External Pressure ModulesFor PCL340 Series- PCL1000 and PCL1200 Calibrators
PCL-PM Series
PLACE ORDER - NIST-Traceable Certificate Included
- 24 Standard Ranges
- Gage, Vacuum, Absolute, Compound, and Differential Measurements
- Accuracy Specified over 15 to 35°C Range
- Isolated and Non-Isolated Measurements, Range Dependent
- Gage, Absolute, and Compound Types are Isolated and Accept Any Media Compatible with 316 SS
- Vacuum and Differential Types are Compatible with Pressure Media that are Clean, Dry, Non-Corrosive Air or Gas
Description
Description
trodeks® offers 24 standardexternal pressure modules foruse with PCL340, PCL1000,and PCL1200 Series calibrators.These modules cover gage,vacuum, absolute, compound,and differential measurements.Pressure ranges can be displayedin any of 13 user-selectable units.Water density correction factors of4°C, 20°C, or 60°F can be selectedfor either water column unit.Note that a pressure unit’sresolution limitations will determinewhether it is the right choice for aparticular application.
Model No. | Parameter Range | Accuracy (%FS) | Over Pressure |
---|
Gage (psig), Ambient Pressure = 0 |
PCL-PM005G | 0 to 5 psi (0 to 350 mbar) | ±0.025%, ±0.003 psi | 400% |
PCL-PM007G | 0 to 7 psi (0 to 500 mbar) | ±0.035%, ±0.0025 psi | 300% |
PCL-PM010G | 0 to 10 psi (0 to 700 mbar) | ±0.025%, ±0.0025 psi | 300% |
PCL-PM030G | 0 to 30 psi (0 to 2 bar) | ±0.025% | 300% |
PCL-PM050G | 0 to 50 psi (0 to 3.5 bar) | ±0.03% | 300% |
PCL-PM100G | 0 to 100 psi (0 to 7 bar) | ±0.025% | 300% |
PCL-PM150G | 0 to 150 psi (0 to 10 bar) | ±0.035% | 200% |
PCL-PM300G | 0 to 300 psi (0 to 20 bar) | ±0.025% | 200% |
PCL-PM1KG | 0 to 1000 psi (0 to 70 bar) | ±0.05% | 200% |
PCL-PM1.5KG | 0 to 1500 psi (0 to 100 bar) | ±0.05% | 200% |
PCL-PM3KG | 0 to 3000 psi (0 to 200 bar) | ±0.1% | 200% |
PCL-PM5KG | 0 to 5000 psi (0 to 340 bar) | ±0.1% | 200% |
Vacuum (psig), Ambient Pressure = 0 |
PCL-PM005VAC | 0 to -5 psi (0 to -350 mbar) | ±0.0.025%, ±0.003 psi | 400% |
PCL-PM015VAC | 0 to -15 psi (0 to -1 bar) | ±0.0.025%, ±0.0025 psi | 300% |
Absolute (psia), Full Vacuum = 0 |
PCL-PM015A | 0 to 15 psi (0 to 1 bar) | ±0.025%, ±0.0025 psi | 300% |
PCL-PM030A | 0 to 30 psi (0 to 2 bar) | ±0.025% | 300% |
PCL-PM050A | 0 to 50 psi (0 to 3.5 bar) | ±0.03% | 300% |
PCL-PM100A | 0 to 100 psi (0 to 7 bar) | ±0.025% | 300% |
PCL-PM300A | 0 to 300 psi (0 to 20 bar) | ±0.025% | 200% |
Compound (psig), Ambient Pressure = 0 |
PCL-PM015C | -15 to 15 psi (-1 to 1 bar) | ±0.025%, ±0.0025 psi | 300% |
PCL-PM030C | -15 to 30 psi (-1 to 2 bar) | ±0.025%, ±0.0025 psi | 300% |
Differential (psid) |
PCL-PM005D | 0 to 5 psi (0 to 350 mbar) | ±0.025%, ±0.003 psi | 400% |
PCL-PM030D | 0 to 30 psi (0 to 2 bar) | ±0.025% | 300% |
PCL-PM050D | 0 to 50 psi (0 to 3.5 bar) | ±0.03% | 300% |
Anemometer | Automation | Accelerometers | Calibrator | Cartridge Heaters | Chart Recorders | Cryogenics | Custom Pressure Transducers | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Fiber Optic Temperature Measurement | Flexible Heaters | Flow Meters | Glass Bulb Thermometers | Grippers | Heaters | Humidity Measurement | Integrated Circuit Sensors | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells | M12 Temperature Connectors | Magnetic Flow Meter | Panel Meter | PID Controllers | pH meter | Pressure Gauges | Pressure Transducers | Pressure Transmitters | Rotameters | RTD | Remote Process Monitoring | Sanitary Sensors | Signal Conditioners | Stepper Motors | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Sensor Manufacturing | Temperature Sensors | Temperature Transmitters | Thermal Imagers | Thermistors | Thermocouple | Thermocouple Wire | Thermowell | Ultrasonic Flow Meters | Vortex Flow Meter | Wireless Sensors