Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
Product Groups
trodeksBUS Computer-to-Analog OutputModules
TRODEKS Engineering | Thermocouples, Pressure Transducers, Flow Meters, PID Controllers
D3000 and D4000
PLACE ORDER 
  • Analog Output Ranges: 0-1 V, ±1 V, 0-5 V, ±5 V, 0-10 V, ±10V, 0-20 mA, 4-20 mA
  • Programmable High/Low Output Limits
  • 500 V rms Output Isolation
  • Scaling in Engineering Units
  • 12-Bit Resolution
  • Baud Rates: 300 to 38,400
  • Output Protection: 240 Vac (CurrentOutput), ± 30 V (Voltage Outputs)
 Specs
 Manuals (contact with email : [email protected])
 Print
Description

Description

The D3000 and D4000 computer-to-analog outputinterfaces are designed to be mounted remotelyfrom a host computer and communicate withstandard RS-232 and RS-485 serial ports. SimpleASCII commands are used to control a 12-bitdigital-to-analog converter that is scaled to provide commonly used current and voltage ranges.An on-board microprocessor provides thecommunications interface and many intelligentanalog output functions. These modules offer anextremely flexible, easy-to-use, and cost-effective approach to data acquisition. The D3000 and D4000 are compatible with thetrodeksBUS®D1000 and D2000 and may be used inany combination. Up to 124 modules may be strung onone set of wires. All modules are supplied with screwterminal plug connectors and captive mountinghardware. The connectors allow system expansion,reconfiguration, or repair without disturbing field wiring.Their small size allows them to be mounted in virtuallyany location or position including explosion-proofhousings and DIN rails. Utility software (D1000-SW)is available upon request at no charge on anIBM-compatible disk.The D4000 modules offer several additionalfeatures. A slew rate may be programmed,which causes the output to ramp at anadjustable rate in either an increasing ordecreasing direction. The ramp can be initiatedand maintained by commands from thecomputer or with external switch closures to themodule. The D4000 module provides areadback feature which allows the computer toverify the integrity of the output.The D4000 modules also include a watchdogtimer circuit that can be set such that if thecomputer fails to communicate with the moduleafter a preset time period, the module will resetitself to an adjustable default value. This featureminimizes the risks of communication failure.The A1000 RS-232 to RS-485 converter and repeatercan be used if an RS-485 port is not available in yourPC, and it is necessary to communicate long distancesaway. The A1000 also provides power for the modules.RS-232 modules can be used for distances less than50 feet.

Common Specifications, D3000 and D4000 ANALOG OUTPUT
• Single channel analog output
     Voltage: 0-1 V, ± 1 V, 0-5 V, ± 5 V, 0-10 V, ± 10 V
     Current: 0-20 mA
• Input isolation to 500 V rms
• 12-bit measurement resolution
• Accuracy (integral and differential non-linearity): 0.1% FSR (max)
• Zero drift: ±30 µV/°C (voltage output) ±1.0µA/°C (current output)
• 1000 conversions per second
• Settling time to 0.1% FS 300 µs typical (1 ms max)
• Programmable output slew rate: 0.01 V/s (mA/s) to 10,000 V/s (mA/s) (D4000 only)
• Autozero and autocalibration-no adjustment pots
• Voltage compliance: ±12 V
• Output current, short circuit current: 5 mA min, 10 mA max

ANALOG OUTPUT READBACK (D4000)
• 8-bit analog-to-digital converter

DIGITAL INPUTS
• Voltage levels: ±30 V without damage
• Switching levels: High, 3.5 V min, low, 1.0 V max
• Internal pull-up resistors for direct switch input

COMMUNICATIONS
• RS-232, RS-485
• Up to 124 modules with A1000 converter/repeater, 32 without A1000
• User selectable channel address (via software command)
• Selectable baud rates: 300, 600, 1200, 2400, 4800, 9600, 19.2K, 38.4K
• ASCII format command/response protocol
• Parity: odd, even, none
• All communications setups (address, baud rate,parity) stored in nonvolatile memory using EEPROM
• Checksum can be added to any command or response
• Communications distance up to 10,000 feet with RS-485 modules

Power Requirements: Unregulated +10 V to +30 Vdc, 0.75 W max (voltage output), 1.0 W max (current output)
Case: ABS with captive mounting hardware
Connectors: screw terminal barrier plug (supplied)
Temperature Range: Operating: -25°C to 70°C
Storage: -25°C to 85°C
Relative Humidity: 0 to 95% non-condensing

Model No.Output RangeInput
      D3000 Series Output Module - Voltage Output
D3121± 1 VRS-232C
D3122± 1 VRS-485
D3131± 5 VRS-232C
D3132± 5 VRS-485
D3141± 10 VRS-232C
D3142± 10 VRS-485
D31610 to 1 VRS-232C
D31620 to 1 VRS-485
D31710 to 5 VRS-232C
D31720 to 5 VRS-485
D31810 to 10 VRS-232C
D31820 to 10 VRS-485
      D3000 Series Output Module - Current Output
D32510 to 20 mARS-232C
D32520 to 20 mARS-485
      D4000 Series Output Module - Voltage Output
D4121± 1 VRS-232C
D4122± 1 VRS-485
D4131± 5 VRS-232C
D4132± 5 VRS-485
D4141± 10 VRS-232C
D4142± 10 VRS-485
D41610 to 1 VRS-232C
D41620 to 1 VRS-485
D41710 to 5 VRS-232C
D41720 to 5 VRS-485
D41810 to 10 VRS-232C
D41820 to 10 VRS-485
      D4000 Series Output Module - Current Output
D42510 to 20 mARS-232C
D42520 to 20 mARS-485
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors