LVDT Signal Conditioner- DC Powered
TRODEKS Engineering | Thermocouples, Pressure Transducers, Flow Meters, PID Controllers
LDX-4
PLACE ORDER 
  • Operates on 10 to 30 Vdc
  • +5V, ±10V, or 20 mA Selectable Outputs
  • Adjustable Zero and Span
  • High-Accuracy Oscillator/ Demodulator Circuits Provide 3 V @ 5 kHz
 Specs
 Manuals (contact with email : [email protected])
 Print
Description

Description

The LDX-4 is a dc powered signal conditioning amplifier and power supply for ac LVDT's. Its compact, rugged case can withstand industrial installations and protect laboratory grade electronics. Complete zero and span adjustments allow the LDX-4 to be used with any LVDT with an output between 45 and 450 mV/V full scale. Selectable outputs of ±5 V or ±10 V interface with recorders, displays, and other instruments. Also, when using the ±5 V output range, a second 0 - 20 mA signal is available for retransmitting the signal over long distances.

SPECIFICATIONS
Supply Voltage: 10 to 30 Vdc
Supply Current (voltage output): 140 mA max. with 10 Vdc supply voltage; 60 mA max. with 30 Vdc supply voltage
Supply Current (current output): 180 mA max. with 10 Vdc supply voltage; 70 mA max. with 30 Vdc supply voltage
Noise on Power Supply (typical): 20 mV pp @ 100 kHz
Input Protection: Over voltage, reverse connection
Transducer Energization: 3V rms @ 5 kHz
Transducer Range:45 to 450 mV/V full scale
Output Voltage (selectable): ±5 Vdc or ±10 Vdc full scale
Load Resistance: 1 kΩ minimum
Analog Output Current: + 20 mA full scale into 1500 Ω maximum (only with 5 V range selected)
Offset Range: 0 to 100%
Gain Temperature Coefficient: < 200 ppm/°C
Output Temperature Coefficient: < 200 ppm/°C
Output Noise: < 20 mV pp @ 10 to 100 kHz
Non-Linearity: < 0.1% BSL
Temperature Range: 0 to 60°C (-18 to 140°F)
Weight (approx.): 300g (11 oz)
Dimensions: 40 H x 65 W x 120 mm L (157 x 256 x 4.72")
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors