Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
PROGRAMMABLE INTERFACE DISPLAY FOR RATE- TOTAL AND CONTROL COMMANDS
FMI-100 Series
PLACE ORDER - Displays Instantaneous and Total Flow
- Digital RS232 or RS485 Interface (Multi-Drop Up to 64 Devices)
- Programmable, Optically- Isolated Pulse and Digital Outputs
- For Use with FMA1700/1800 or FMA5400/5500 Series
- 16 Point Programmable Controls, With Ramping Up/Down
- Free Configuration and Monitoring Utility Software
Description
Description
The FMI-100 Series is forflowmeters and controllers withanalog 0 to 5, 5 to 10, 0 to 10 Vdcor 4 to 20 mA input output interface,where flow indications/control,totalizers or alarm functions arerequired. Also when re-transmissionof the flow rate and/or totalizerfunctions via optically-isolated pulseoutput or serial communication isdesired. Local or programmable setpoint control for flow controllers (nohost PC presence required).The graphical LCD has large13 mm (0.51") digits for flow rateand 5.5 mm (0.21") for total and canbe set by user to simultaneouslyshow different combination of theflow parameters: flow rate,totalizers, flow alarms, anddiagnostic events. All configurationparameter settings are easilyaccessed via a simple user-interfacemenu driven by a 6 button key-padwhich can be password-protected.For flowmeters and/or flowcontrollers, FMI-100 providesjumpers selectable for 0 to 5 Vdc or4 to 20 mA analog set point controlsignals. The flow rate set point canbe adjusted locally via key-pad,remotely via host PC using digitalcommunication interface, orprogrammed in advance usingbuilt-in 16 steps batch table withramping up/down support.The programmable flow pulseoutput operates independentlyfrom the totalizers and based onconfiguration settings can providepulse frequency proportional toinstantaneous fluid flow rate. TheFMI-100 provides two independentprogrammable flow totalizers.Both totalizers are updated every100 ms and can be set to activatedifferent events. Main totalizeraccumulated total is backed-upin EEPROM memory everysecond. And it provides the userwith a flexible alarm/warningsystem that monitors the fluidflow for conditions that fall outsideconfigurable limits as well as visualfeedback for the user via the LCDor via an optically-isolated output.All process data and settings canbe read and modified manually vialocal LCD key-pad or through thedigital RS232 or RS485communication interface. ProprietaryASCII software interface commandset and free Communication Utilitysoftware are provided.
Specifications
ADC/DAC Resolution: 12-bit
Analog Inputs: 0 to 5 Vdc, 4 to 20 mA, 5 to 10 Vdc (jumper-selectable), 0 to 10 Vdc (contact Flow Engineers at trodeks for details)
Analog Outputs: 0 to 5 Vdc, 4 to 20 mA (jumper-selectable)
LCD: 128 x 64 graphic LCD with instantaneous flow reading and total volume indication, adjustable LCD contrast and back light
Key-Pad: Local 6 tactical push buttons
Pulse Output: User-programmable, optically-isolated, with preset active low time interval (10 to 6550 mS).
Digital Output: Two programmable, optically-isolated, UCE @ 40 Vdc, ICE @ 150 mA (voltage isolation; 250 Vrms)
Digital Interface: RS232 or RS485 (multidrop capability up to 64 devices)
Protocol: Proprietary ASCII software interface command set
Speed: 1200/2400/4800/9600/19200/38400/57600/115200 baud (user selectable)
Configuration:
Stop Bit: 1
Data Bits: 8
Parity: None
Flow Control: None
Addressing: Maximum 255 addresses (for RS485 option only)
Type: RS232 or RS485 2-wire
Power Requirements: 12 to 26 Vdc (up to 60 mA maximum)
Interface Connectors: Process I/O signals and digital RS232/RS485 interface, miniature 9-pin female D-SUB connector; digital optically-isolated outputs; TERM BLOCK HEADER 4POS 3.5 mm male pins, shrouded
Environment: Installation Level II, Pollution Degree II, (per IEC 664)
Electromagnetic Compatibility: Compliant ref. 89/336/EEC as amended; emission standard; EN 55011:1991, Group 1, Class A immunity standard: EN 55082- 1:1992
Operating Temperature: -10 to 70°C (14 to 158°F)
Dimensions: 86.4 W x 76.2 H x 19.1 mm D (3.4 x 3.0 x 0.75")
Weight: Approximately 125 g (0.3 lb) Anemometer | Automation | Accelerometers | Calibrator | Cartridge Heaters | Chart Recorders | Cryogenics | Custom Pressure Transducers | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Fiber Optic Temperature Measurement | Flexible Heaters | Flow Meters | Glass Bulb Thermometers | Grippers | Heaters | Humidity Measurement | Integrated Circuit Sensors | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells | M12 Temperature Connectors | Magnetic Flow Meter | Panel Meter | PID Controllers | pH meter | Pressure Gauges | Pressure Transducers | Pressure Transmitters | Rotameters | RTD | Remote Process Monitoring | Sanitary Sensors | Signal Conditioners | Stepper Motors | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Sensor Manufacturing | Temperature Sensors | Temperature Transmitters | Thermal Imagers | Thermistors | Thermocouple | Thermocouple Wire | Thermowell | Ultrasonic Flow Meters | Vortex Flow Meter | Wireless Sensors
trodeks.comtrodeks.com - فقخیثنس.زخئ - صصص.فقخیثنس.زخئ