Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
Product Groups
Ultrasonic Doppler Flowmeter
TRODEKS Engineering | Thermocouples, Pressure Transducers, Flow Meters, PID Controllers
FD-400 Series
PLACE ORDER 
  • Non-Intrusive, Clamp-On Transducer for Most Pipes from 6 mm to 3m (1/4 to 120")
  • Insertion Probe Transducer Also Available
  • Wide Measuring Range of 0.05 to 9 mps (0.15 to 30 fps)
  • ±2% of Calibrated Span Accuracy
  • Configuration and Total Stored in Non-Volatile Flash ROM
  • NEMA 4X (IP66) Outdoor Enclosure
  • Provisions for Up to 4 Meters in a Single Piping System
  • NIST Certificate
 Specs
 Manuals (contact with email : [email protected])
 Print
Description

Description

The FD-400 Series ultrasonicdoppler flowmeters measure theflow of liquids that contain soundreflectors, suspended solids, or gasbubbles larger than 100 microns.These sophisticated instrumentsautomatically adjust filtering andgain settings to produce reliablereadings in a wide range of liquidand reflector conditions.

The FD-400 flowmeter transmittsultrasonic sound through the pipewall or from the probe tip into theflowing liquid by using piezoelectriccrystals contained in the transducerand probe tip. The sound is thenreflected by sonic reflectorssuspended in the liquid andrecorded by the receiver. If thesonic reflectors are moving withinthe sound transmission path, soundwaves will be reflected at afrequency shifted (Doppler frequency)from the transmitted frequency. Thedifference between the 2 frequenciesis directly proportional to the speedof the sonic reflectors, resulting in aliquid flow rate that is converted tovarious user-defined units.

Configuration of the FD-400 isaccomplished via the front-panelkeypad. A 2-line backlit LCD displaysrate and total in user-selected units.Power supply options include ACand DC. Optional outputs include4 to 20 mA, relays, and rate pulse.

Two transducer styles are available.The FD-400C clamp-on, non-intrusivetransducer is recommended for mostmetal or plastic pipes. The FD-400Chas a NEMA 6P (IP68) rating and isavailable in a high-temperatureversion, "=HT". The user can placethese clamp-on transducers up to305 m (1000') from the displayenclosure. The FD-400I insertionprobe transducer should be usedon piping systems that do notpermit ultrasonic penetration. TheFD-400I inserts into the pipe walland comes into direct contact withthe flowing liquid.

SPECIFICATIONS
GENERAL

Measuring Principle: Doppler ultrasonic
Flow Velocity Range: 0.05 to 9 mps (0.15 to 30 fps)
Accuracy: ±2% FS over calibrated span
Liquid Types: Liquids containing 100 ppm of useful sonic-suspended reflectors greater than 100 microns

MONITOR
Enclosure: NEMA 4X (IP66), polycarbonate, stainless steel, brass, plated-steel mounting brackets
Dimensions: 178 H x 146 W x 99 mm D (7.00 x 5.75 x 3.88")
Power Supply: 115/230 Vac, 50/60 Hz ±15% @ 5 VA max; 12 to 28 Vdc @ 2.5 VA max
Display: 2-line x 8-character LCD; LED backlighting; top row, 7-segment 18 mm (0.7"); bottom row, 14-segment 9 mm (0.35"); 8-digit rate, 8-digit total (resettable)
Units: User configured—feet, gallons, ft3, mil-gal, meters, liters, mil ft3, m3, mil-liters, acre-feet, oil barrels (42 gallon), liquor barrels (32.5 gallons), lb, kg
Rate: Interval—second, minute, hour, day
Totalizer exponent: E-2 to E+6
Response Time: User selectable, 1 to 60 seconds
Outputs: 4 to 20 mA, 800 Ω max; internal or external power supply; 12-bit resolution; optically isolated
Dual Relay: Independently configured; form “C”, 200 Vac @ 0.5 A resistive; rate alarm, totalizer pulse, error
Rate Pulse: 2 output types— 500 mVac or open collector; 2500 Hz max; 12-bit resolution; 500 mV AC into 2 kΩ min; open collector 1 A at 100 V max
Multiple Meters: Synchronization provision included—used for multiple meter/single pipe system; up to 4 meters may be interconnected to 30 m (100') apart
Keypad: 4 pushbutton keys
Operating Temperature: General purpose, 40 to 85°C (40 to 185°F)

TRANSDUCERS
Type: Compression-mode ultrasonic, 625 kHz
Housing Material:
    Standard Clamp-On: NEMA 6P (IP68), -40 to 100°C (-40 to 210°F), CPVC, Ultem®, nylon, PVC (cable jacket), aluminum (small pipe)
    High-Temp Clamp-On: NEMA 4 (IP65), -40 to 200°C (-40 to 400°F), Vespel®, anodized aluminum, nickel-plated brass, PFA (cable jacket)
    Doppler Probe: NEMA 6 (IP67) -40 to 100°C (-40 to 210°F); 700 psi (48 bar) max, 316 SS, Ultem®, FKM, nylon, PVC (cable jacket)
    Optional Flexible Armored Conduit: Zinc-plated steel, PVC
Cable Length:
    Standard Lengths: 6 m (20') standard
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors