Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
Economical Ball Bearing Turbine Flowmeters With 37° Flare Fittings
FTB-200 Series
PLACE ORDER - ±0.5% of Reading Accuracy
- Ball Bearing Design for Economy
- Deflector Cones Stabilize Low Mass Rotor for Increased Bearing Life
- NIST Certificate for Water Included
Description
Description
trodeks® FTB-201 Series turbine meters have male flared-end fittings for easy connections. They are built to meet the performance requirements of MS 33656, though they do not carry a militaryspecification. These units come with a mating 2-wire connector and can be supplied with the integrallymounted signal conditioners (Please see the for more information) to provide 4 to 20 mA, 0 to 5V, and factored pulse outputs.
Flow Straightening
Proper application of a turbine flowmeter requires that there be a suitable piping section both downstream and upstream of the meter if it is to achieve optimum accuracy. Whereas an inlet straight pipe run of 10 pipe diameters and an outlet straight pipe run of 5 pipe diameters provide the necessary flow conditioning in general, some applications require an upstream flow straightener. Such applications include custody transfer. A flow straightener consists of a section of piping which contains a suitably dimensioned and positioned thin walled tube cluster to eliminate fluid swirl. (see full specifications for "Typical Turbine Meter Installation Drawing".
37° Flare Installation Kits
Installation kits with the required up and downstream straight pipe lengths for proper turbine operation are available. Installation kits for turbine meters with 37° flare end fittings consist of two lengths of stainless steel tubing cut to a length appropriate for the upstream and downstream straight pipe runs and flared at one end. Mating sleeves and nuts are included. The kits can be conveniently butt-welded into the piping system. Flow straightening sections may be provided with the installation kit. Kits are available in tubing sizes from ½ to 2 ½".
Strainers and Filters
Turbine meters are intended for clean fluid service only; where there is any doubt concerning possible particulate impurities in the process fluid, strainers are recommended. A strainer/filter may be required to reduce the potential hazard of fourling or damage that can be caused by foreign matter. Pipe rouge, the extremely fine rust which develops on the inside of some piping, is a serious problem for turbine meters, due to the difficulty in filter out these particles. Consult trodeks Flow Engineering Department for applications that may entail pipe rouge.
When using FTB-200 Series units for fluids with viscosities other than 1 centistoke, special calibrations and universal viscosity curves are available, consult trodeks’s Flow Engineering Department for quote.
Meter Size | Mesh Size | Maximum Partical Size (in) |
1/4 to 1/2" | 100 | 0.0055 |
5/8 to 1 1/4" | 70 | 0.008 |
1 1/2 to 2 1/2" | 40 | 0.015 |
SPECIFICATIONS
Accuracy: ±0.5% of reading
Repeatability: ±0.1% of reading
Temperature Range: -268 to 232°C (-450 to 450°F)
Maximum Intermittent Overrange: 150% of maximum range
Materials of Construction:
Body: 304 SS;
Rotor: 17-4 PH SS
Bearings: 440C SS
Installation Kits: 340 SS, 1.7 mm (0.065") thick
Electrical: Two-wire connector, included
Max Pressure Drop: 0.34 bar (5 psi)
Model No. | 37° Flare Fitting Size | Linear Range Water | Max Operating Pressure | Length | Nominal K-Factor pulses/gal | Weight kg (lb) |
FTB-201 | 3/4-16 UNF-3A | 0.35 to 3.5 GPM | 5000 psi | 62 mm (2.45") | 13,000 | 0.4 kg (1 lb) |
FTB-202 | 3/4-16 UNF-3A | 0.75 to 7.5 GPM | 5000 psi | 62 mm (2.45") | 10,000 | 0.4 kg (1 lb) |
FTB-203 | 3/4-16 UNF-3A | 1.25 to 9.5 GPM | 5000 psi | 62 mm (2.45") | 6,000 | 0.4 kg (1 lb) |
FTB-204 | 7/8-14 UNF-3A | 1.75 to 16 GPM | 5000 psi | 70 mm (2.75") | 4,100 | 0.4 kg (1 lb) |
FTB-205 | 1-1/16-12 UNF-3A | 2.5 to 29 GPM | 5000 psi | 83 mm (3.25") | 2,200 | 0.4 kg (1 lb) |
FTB-206 | 1-15/16-12 UNF-3A | 4 to 60 GPM | 3500 psi | 89 mm (3.50") | 640 | 0.9 kg (2 lb) |
FTB-207 | 1-5/8-12 UNF-3A | 6 to 93 GPM | 3000 psi | 99 mm (3.88") | 410 | 0.9 kg (2 lb) |
FTB-208 | 1-7/8-12 UNF-3A | 8 to 130 GPM | 2250 psi | 111 mm (4.38") | 230 | 1.4 kg (3 lb) |
FTB-209 | 2-1/2-12 UNF-3A | 15 to 225 GPM | 1750 psi | 121 mm (4.75") | 120 | 1.8 kg (4 lb) |
Anemometer | Automation | Accelerometers | Calibrator | Cartridge Heaters | Chart Recorders | Cryogenics | Custom Pressure Transducers | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Fiber Optic Temperature Measurement | Flexible Heaters | Flow Meters | Glass Bulb Thermometers | Grippers | Heaters | Humidity Measurement | Integrated Circuit Sensors | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells | M12 Temperature Connectors | Magnetic Flow Meter | Panel Meter | PID Controllers | pH meter | Pressure Gauges | Pressure Transducers | Pressure Transmitters | Rotameters | RTD | Remote Process Monitoring | Sanitary Sensors | Signal Conditioners | Stepper Motors | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Sensor Manufacturing | Temperature Sensors | Temperature Transmitters | Thermal Imagers | Thermistors | Thermocouple | Thermocouple Wire | Thermowell | Ultrasonic Flow Meters | Vortex Flow Meter | Wireless Sensors