Digital Input panel meters - Count and Rate meter
TRODEKS Engineering | Thermocouples, Pressure Transducers, Flow Meters, PID Controllers
DPF9300
PLACE ORDER 
  • Count, Dual Count, Rate and Slave Display
  • 50 x 97 mm (2 x 3.8")
  • 6-Digit, 14 mm (0.56") LED
  • Variable Intensity Display
  • 10-Point Scaling for Non-Linear Inputs (DPF9300 Series)
  • NEMA 4X(IP65) Sealed Front Bezel
 Manuals (contact with email : [email protected])
 Print
Description

Description

The DPF9300 digital inputpanel meter offer many featuresand performance capabilities tosuit a wide range of industrialapplications. The DPF9300 offers bothcounting and rate in the samepackage. Theoptional plug in output cards allowthe opportunity to configure themeter for present applications,while providing easy upgrades forfuture needs. The meters employa bright 14 mm (0.56") LED display.The intensity of the red LED displaycan be adjusted from dark roomapplications up to sunlight readable,making it ideal for viewing in brightlight applications. The metersaccept digital inputs from a varietyof sources including switchcontacts, outputs from CMOS orTTL circuits, magnetic pickups and all standard RLC sensors. Themeter can accept directional, unidirectionalor quadrature signalssimultaneously. The maximum inputsignal varies up to 34 KHzdepending on the count modeand function configurationsprogrammed. Each input signalcan be independently scaled tovarious process values. The ratemeters provide a MAX and MINreading memory with programmablecapture time. The capture time isused to prevent detection of falsemax or min readings which mayoccur during start-up or unusualprocess events. The meters havefour set point outputs, implementedon plug-in option cards. The plug-incards provide dual FORM-C relays(5A), quad FORM-A (3A), or eitherquad sinking or quad sourcing opencollector logic outputs. The set pointalarms can be configured to suita variety of control and alarmrequirements. Communication andBus capabilities are also availableas option car through the bus.Additionally, the meters have afeature that allows a remotecomputer to directly control theoutputs of the meter.

With an RS232 or RS485card installed, it is possible toconfigure the meter using .The configuration data can besaved to a file for later recall. Alinear DC output signal is availableas a plug in option card. The cardprovides either 20 mA or 10Vsignals. The output can be scaledindependent of the input range andcan track any of the counter or ratedisplays.

Once the meters have been initiallyconfigured, the parameter list maybe locked out from furthermodification in its entirety or onlythe set point values can be madeaccessible. The meters have beenspecifically designed for harshindustrial environments. WithNEMA 4X(IP65) sealed bezel andextensive testing of noise effectsto CE requirements, the meterprovides a tough yet reliableapplication solution.

SPECIFICATIONS
Display: 6-digit, 14.2 mm (0.56") red LED, (-99999 to 999999)
POWER
AC Powered Units: 85 to 250 Vac, 50/60 Hz, 18 Va
Isolation: 2300 Vrms for 1 min. to all inputs and outputs (300V working)
DC Powered Units: 11 to 36 Vdc, 14 W (derated operating temperature to 40°C (104°F) if operating <15 Vdc and three plug in option cards are installed)
AC Power: 24 Vac, ±10%, 50/60 Hz, 15 Va
Isolation: 500 Vrms for 1 min. to all inputs and outputs (50V working)
Sensor Power: 12 Vdc, ±10%, 100 mA max short circuit protected
Keypad: 3 programmable function keys, 5 keys total
User Inputs: Three programmable user inputs
Max Continuous Input: 30 Vdc Isolation to Sensor Input Commons: Not isolated
Logic State: Jumper selectable for sink/source logic
INPUT STATE
Sinking Inputs: 5.1KΩ pull-up to +12V
Active: Vin<0.9 Vdc
Inactive: Vin>3.6 Vdc
Sourcing Inputs: 5.1KΩ pull-down
Active: Vin>3.6 Vdc
Inactive: Vin<0.9 Vdc
Response Time: 6 msec. typical; function dependent. Certain resets, stores and inhibits respond within 25 ?sec if an edge occurs with the associated counter or within 6 msec if no count edge occurs with the associated counter. These functions include CtrStL, CtrStE, HLrStL, HLrStE, INHlbt, StOrE, and PrNsSt. Once activated, all functions are latched for 50 msec min. to 100 msec max. After that period, another edge/level may be recognized
Memory: Nonvolatile E2PROM retains all programmable parameters and display values.
ENVIRONMENTAL CONDITIONS
Operating Temperature Range: 0 to 50°C (32 to 122°F) [0 to 45°C (32 to 113°F) with all three plug-in cards installed]
Storage Temperature Range: -40 to 60°C (-40 to 140°F) Operating and Storage Humidity: 0 to 85% max relative humidity non-condensing
Altitude: Up to 2000 meters
Connections: High compression cageclamp terminal block
Wire Strip Length: 7.5 mm (0.3")
Wire Gage: 30-14 AWG copper wire
Torque: 4.5 inch-lbs (0.51 N-m) max
Construction: This unit is rated for NEMA 4X/IP65 outdoor use. IP20 Touch safe. Installation Category II, Pollution Degree 2. One piece bezel/case. Flame resistant. Synthetic rubber keypad. Panel gasket and mounting clip included.
Weight: 10.1 oz (286 g)
COUNTER DISPLAYS Maximum Display: 8 digits: ± 99999999 (greater than 6 digits display alternates between high order and low order)
RATE DISPLAY Accuracy: ±0.01%
Minimum Frequency: 0.01 Hz
Maximum Frequency: 34 KHz (depending on set-up)
Maximum Display: 5 Digits: 99999 Adjustable Display (low) Update: 0.1 to 99.9 seconds
Over Range Display: "rOLOL"
INPUTS A or B: DIP switch selectable to accept pulses from a variety of sources including switch contacts, TTL outputs, magnetic pickups and all standard RLC sensors.
Logic: Input trigger levels VIL=1.5V max; VIH=3.75V min.
Current Sinking: Internal 7.8 KΩ pull-up to +12 Vdc, IMAX=1.9 mA.
Current Sourcing: Internal 3.9 KΩ pull-down, 7.3 mA max @ 28 Vdc, VMAX=30 Vdc.
Filter: Damping capacitor provided for switch contact bounce. Limits input frequency to 50 Hz and input pulse widths to 10 msec. minimum.
MAGNETIC PICKUP Sensitivity: 200 mV peak
Hysteresis: 100 mV
Input Impedance: 3.9 KΩ @ 60 Hz
Maximum Input Voltage: ±40V peak, 30 Vrms
DUAL COUNT MODES When any dual count mode is used, then User Inputs 1 and/or 2 will accept the second signal of each signal pair. The user inputs do not have the Logic/Mag, High/Low Freq, and Sink/Source input setup switches. The user inputs are inherently a logic input with no low frequency filtering. Any mechanical contacts used for these inputs in a dual count mode must be debounced externally. The user input may only be selected for sink/source by the User Jumper placement.
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors