Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
Toroidal Conductivity System
CDTX-45T
PLACE ORDER - Loop-Powered, AC, or Battery Versions
- Dual Alarm Relays/Analog Outputs
- Large, 2-Line Display
Description
Description
The CDTX-45T toroidal conductivity system is designed foronline monitoring of chemically aggressive process solutions,water applications that coat or foul traditional sensors, andplating bath operations in which high current densities arepresent. The sensor consists of 2 metallic ribbon coils that arefixed in place by the sensor jacket material. The drive coil isused to induce a current in the process solution. The secondsensing coil is used to measure the current in the processsolution; the magnitude of this current is proportional to theconductivity of the process solution. Toroidal sensor is available in Norylto ensure that sensor-wetted materials are chemically resistant to processchemicals. The sensor material is non-conductive, therebyisolating the sensor from electrical noise and ground loops thatcan influence the integrity of the measurement. This materialalso makes the sensor resistant to electrode coating, sincemost substances do not adhere to the sensor material.Sensor can be submersion mounted for easy installation inopen tanks or pipe mounted in the optional 2" tee fitting, whichis keyed to the sensor for proper alignment. Tee fitting materialis polypropylene. For larger pipe diameters,the sensor can be insertion mounted through a 1 1/2 NPT ballvalve for easy retraction. The CDTX-45TC is the concentrationmonitor. The monitor comes with concentration/temperaturetables for sodium hydroxide, potassium hydroxide, hydrochloricacid, nitric acid, and sulfuric acid.
MONITOR PERFORMANCE SPECIFICATIONS
Measuring Range:
Main Input: 0 µS to 2000 mS, mg/L total dissolved solids; loop current 4 to 20 mA
Sensor Temperature: -10 to 210ºC (14 to 410ºF)
Main Parameter Ranges: 0 to 2000 µS, 0 to 2 mS, 0 to 20 mS, 0 to 200 mS,
0 to 2000 mS, 0 to 2 S
Repeatability: 0.3% of span or 0.1 µS, whichever is greater
Sensitivity: 0.05% of span or 0.1 µS, whichever is greater
Non-Linearity: 0.3% of span or 0.1 µS, whichever is greater
Stability: 0.1% of span per 24 hr
Temperature Drift: Span or zero, 0.03% of span/ºC
Warm-Up Time: 7 s to rated performance
Response Time: 6 s to 90% of step input at lowest setting Max Sensor-to-Analyzer Distance: 61 m (200')
SENSOR SPECIFICATIONS
Sensor: Toroidal electrode
Wetted Materials: Noryl
Sensor Cable: 6.1 m (20') standard, maximum length 61 m (200')
Response Time: 2 s to 90% FS
Temperature Range: 0 to 105°C (32 to 221°F)
Pressure Limit: 150 psig
Process Connection: 3/4 MNPT rear thread, optional 2" keyed tee fitting
Temperature Element: Pt1000 RTD
Minimum Conductivity: 500 µS
INSTRUMENT SPECIFICATIONS
Enclosure:
Materials: NEMA 4X (IP66) polycarbonate, stainless steel hardware,
weatherproof and corrosion resistant
Dimensions: 112 H x 112 W x 89 mm D (4.4 x 4.4 x 3.5")
Mounting Options: Wall, panel (115 x 115 mm) or pipe/handrail
Conduit Openings: 3 M16 openings; cord grips and conduit adaptors included
Weight:
Loop-Powered Transmitter: 0.45 kg (1 lb)
Other Configurations: 0.68 kg (1.5 lb)
Display: Large, high-contrast, super-twist (STN) LCD 4-digit main display with sign, 19.1 mm (0.75") 7-segment characters; 12-digit alphanumeric second-line display, 7.6 mm (0.3") 5 x 7 dot matrix characters
Keypad: 4-key membrane type with tactile feedback, polycarbonate with UV coating, integral EMI/static shield and conductively coated window
Ambient Temperature:
Operating: -20 to 60ºC (-4 to 140ºF)
Storage: -30 to 70ºC (-22 to 158ºF)
Ambient Humidity: 0 to 95% RH, non-condensing
Designed for hazardous and non-hazardous areas
EMI/RFI Influence: Designed to EN 61326-1
Output Isolation: 600 V galvanic isolation
Filter: Adjustable, 0 to 9.9 minutes additional damping to 90% step input
Temperature Input: Selectable Pt1000 or Pt100 RTD with automatic compensation
Please download specification page for complete list of available models. Anemometer | Automation | Accelerometers | Calibrator | Cartridge Heaters | Chart Recorders | Cryogenics | Custom Pressure Transducers | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Fiber Optic Temperature Measurement | Flexible Heaters | Flow Meters | Glass Bulb Thermometers | Grippers | Heaters | Humidity Measurement | Integrated Circuit Sensors | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells | M12 Temperature Connectors | Magnetic Flow Meter | Panel Meter | PID Controllers | pH meter | Pressure Gauges | Pressure Transducers | Pressure Transmitters | Rotameters | RTD | Remote Process Monitoring | Sanitary Sensors | Signal Conditioners | Stepper Motors | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Sensor Manufacturing | Temperature Sensors | Temperature Transmitters | Thermal Imagers | Thermistors | Thermocouple | Thermocouple Wire | Thermowell | Ultrasonic Flow Meters | Vortex Flow Meter | Wireless Sensors