The OM-CP-QUADSTATE is a fourchannel, battery powered, standalone state recorder. This is an all-in-one compact, portable, easy touse device that will measure andrecord up to 52,428 state changes.The OM-CP-QUADSTATE sensesinput transitions or contact closuresfrom external sources such astransducers and/or state initiatorsand records the time and input stateof the device when a transitionoccurs.
The storage medium is non-volatilesolid state memory, providingmaximum data security even if thebattery becomes discharged. Thedevice can be started and stoppeddirectly from your computer and itssmall size allows it to fit almostanywhere.
The OM-CP-QUADSTATE makesdata retrieval quick and easy.Simply plug it into an availableCOM port and our user-friendlysoftware does the rest.The software converts your PCinto a real time strip chart recorder.Data can be printed in graphical ortabular format and can be exportedto a text or Microsoft Excel file.
Specifications
Input Connection: 4 removablescrew terminals
Input Low: <0.4 V
Input High: >2.7 V
Input Range: 0 to 12 Vdc continuous (0 to 30 Vdc peak)
Duty Cycle Limitation:
24 V:10% <6 seconds per minute)
18 V:25% <15 seconds per minute)
12 V:50% <30 seconds per minute)
Input Impedance: >1K Ω
Time Resolution: 1 second (reading rate dependent)
Engineering Units: User may define units up to 10 characters in
length.This value is stored within the device
Scale Factor: User may program any desired scaling factor from
±1.000E-31 to ±9.999E+31. The scaling factor is stored within the device
Start Modes: Software programmable immediate start or delay start
up to six months in advance
Reading Rate: 1 reading every second to 1 every 12 hours
Memory: 52,484 state changes; 209,939 readings; software configurable memory wrap
Real Time Recording: May be used with PC to monitor and record
data in real time
Calibration: Digital calibration through software
Calibration Date: Automatically recorded within device
Power:9 V lithium or alkaline battery included; 120 Vac power optional
Battery Type: 9V lithium or alkaline battery included; user replaceable
Battery Life: 1 year typical
Data Format: Date and time stamped state changes (on/off)
engineering units specified through software
Time Accuracy: ±1 minute/month (at 20°C, RS-232 cable not in use)
Computer Interface: PC serial or USB (interface cable required; 2,400
required); 2400 baud
Software: XP SP3/Vista/7 and 8 (32 and 64-bit)
Operating Environment: -20 to 60°C (-4 to 140°F)
0 to 95% RH non-condensing
Dimensions: 3.5 x 4.4 x 1.0"
(89 H x 111 W x 26 mm D)
Weight: 370 g (13 oz) Anemometer | Automation | Accelerometers | Calibrator | Cartridge Heaters | Chart Recorders | Cryogenics | Custom Pressure Transducers | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Fiber Optic Temperature Measurement | Flexible Heaters | Flow Meters | Glass Bulb Thermometers | Grippers | Heaters | Humidity Measurement | Integrated Circuit Sensors | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells | M12 Temperature Connectors | Magnetic Flow Meter | Panel Meter | PID Controllers | pH meter | Pressure Gauges | Pressure Transducers | Pressure Transmitters | Rotameters | RTD | Remote Process Monitoring | Sanitary Sensors | Signal Conditioners | Stepper Motors | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Sensor Manufacturing | Temperature Sensors | Temperature Transmitters | Thermal Imagers | Thermistors | Thermocouple | Thermocouple Wire | Thermowell | Ultrasonic Flow Meters | Vortex Flow Meter | Wireless Sensors