Portable Data Logger with 16 or 32 Universal Inputs Plus 2 HighVoltages- 4 Pulse and 8 DigitalEvent-State Inputs
TRODEKS Engineering | Thermocouples, Pressure Transducers, Flow Meters, PID Controllers
OM-SQ2040-2F16
PLACE ORDER 
  • 16 True Differential or 32 Single-Ended Universal Analog Inputs for Voltage, Current or Resistance Measurements - Plus 2 High Voltages, 4 Pulse and 8 Digital Event/State Inputs
  • Analog Inputs Can Be Used with Thermistors, Thermocouples, 2, 3 or 4-Wire RTD Temperature Sensors and 4 to 20 mA Signals
  • User Selectable Logging Rates of Up to 100 Hz on Up to 4 Channels
  • Download of Internal Data to Removable MMC/SD (Multi Media Card/Secure Digital) Memory
  • Large Non-Volatile Internal Memory - Data Retention is Virtually Indefinite
  • Ethernet, Wi-FI (On the OM-SQ2040-2F16-WIFI and OM-SQ2040-4F16-WIFI) USB and RS-232 Communication Ports
  • Ethernet, USB and RS-232 Communication Ports
  • Sensor Power and FET Alarm Outputs For Use With External Devices
  • Easy Access to Information Using the 2 Line, 20 Character LCD and Push Button Panel
  • Calculated Channels Derived from Real Channels Using Advanced Mathematical Functions
 Manuals (contact with email : [email protected])
 Print
Description

Description

The OM-SQ2040 Series combines a higher channel count with the samehigh performance, comprehensive features and universal inputs as theOM-SQ2020 in a neat compact and portable instrument.Using multiple 24-bit analog to digital convertors, twin processors andremovable memory options provide great flexibility to handle a wide rangeof complex and demanding multichannel applications.

The OM-SQ2040 series are the ideal data loggers for industrial,scientific research and quality assurance applications.The OM-SQ2040 provides standalone data acquisition, advancednetworked solutions and data analysis straight out-of-the-box.

Input Connections:
The OM-SQ2040-2F16 data logger has two analog to digital converters(A/D’s) which increases logging flexibility over the OM-2020-1F8model. The first corresponds to inputs on blocks A, B, C and D andthe second corresponds to inputs on blocks G, H, J and K.Each connection block will accept up to 2 differential inputs or upto 4 single-ended inputs (it is not possible to mix single ended anddifferential inputs on a block).The OM-SQ2040-4F16 data logger has four analog to digital converters(A/D’s) which increases logging flexibility over the other OM-SQ2020and OM-SQ2040 models. The first corresponds to inputs on blocks Aand B, the second corresponds to inputs on blocks C and D, the thirdcorresponds to inputs on blocks G and H and the fourth correspondsto inputs on blocks J and K. Each connection block will acceptup to 2 differential inputs or up to 4 single— ended inputs (it is notpossible to mix single-ended and differential inputs on a block).

Concurrent Sampling:
The OM-SQ2040 series uses |multiple analog to digital convertersthat enables true concurrent sampling and logging. This allows the user toconfigure up to 4 channels to log at a rate of 100 Hz while retaining differentsample speeds on other channels. This makes the OM-SQ2040 ideal formeasuring dynamic parameters that change at different rates such astemperature and pressure.

Communications:
Ethernet, Wi-Fi (on the OM-SQ2040-2F16-WIFI and OM-SQ2040-4F16-WIFI) USB and RS-232 serial ports are built-in. This allows quick connection to either a PC based TCP/IP network, a wireless to PC connection or to a modem for remote data downloading.This flexibility enables global data access and retrieval as well ascomplete system integration of the OM-SQ2040 series into complexand critical applications.

Multiple Configurations Stored in the Logger:
Up to six logger configurations (channel type,names, logging speeds, triggers, etc.), togetherwith the current configuration, can be held in thelogger’s internal memory. Additional configurationsettings can also be loaded from the externalMMC/SD memory card. This allows the operator to quickly and easilyswitch between logger configurations withoutthe need for a PC.

Comprehensive Software Configuration
The OM-SQ-SOFT software (supplied with the OM-SQ2040 series data loggers) allows loggerconfiguration, data download and data export whilegiving the user full control over the OM-SQ2040.The optional OM-SQ-SOFT-PLUS software gives theuser access to many advanced data analysis and dataarchiving/transfer features. The optional OM-SQ-SOFT-PLUS software lets youquickly and easily analyze the data from yourOM-SQ2040 data logger in a familiar Explorer styleinterface. Data can be displayed with 2 different autoscaling Y-axis. This is particularly useful whendisplaying widely varying data from different sensors on one graph.You can also zoom in on areas of interest, use acursor to pick out exact values, times and dates, getastatistical summary of your data, set high and lowalarm thresholds and, using the calculation function,you can create new virtual channels from existingchannels.

The OM-SQ-SOFT-PLUS software also incorporates areport generation facility, which allows you to createcustom report templates consisting of a title page withdescriptive text, headers and footers, graphs, tabularlist of data, statistics and data logger setupinformation. Templates can be setup with any of thesecombinations and saves time when preparing similarpresentations of data.

Specifications
ANALOG INPUTS
Accuracy:
See table on PDF
Common Mode Rejection: 100 dB
Input Impedance: >1MÙ
Linearity: 0.015%
Series Mode Line Rejection: 50/60 Hz 100 dB
Analog Input Connections: Detachable screw terminal blocks

ANALOG - DIGITAL CONVERSION
Type:
Sigma-Delta
Resolution: 24-bit
Sampling Rate: Up to 10, 20* or100* readings per second per ADC.* With mains rejection off

ALARM OUTPUTS
4 x open drain FET (18 V 0.1 A)
Digital I/O Connections: DB25F connector

CALCULATED CHANNELS
Up to 16 virtual channels derived from physical input channels

RESOLUTION
Up to 6 significant digits

PROGRAMMING/LOGGER SETUP
OM-SQ-SOFT or OM-SQ-SOFT-PLUS software; software compatiblewith WIN XP/VISTA
(32-bit & 64-bit)/7 (32-bit & 64-bit)

COMMUNICATION
Standard:
RS-232 (automatic baud rate selection to 115200baud) Ethernet 10/100 base TCP/IP USB 1.1 and 2.0 compatible
Wireless Ethernet: (Wi-Fi); 802.11b, 2.4GHz,1 to 14 channels Security: Open, WEP (64 or 128biencryption), WPA or PA2/802.11iNetwork: Infrastructure only withspecified SSID (external powerpack required for Wi-Ficonnection)
External Options: GSM, WIFI and PSTN Modems

POWER SUPPLY
Internal:
6 "AA" alkaline batteries (included)
External: 10 to 18 Vdc reversepolarity and over-voltage protected

POWER CONSUMPTION @ 9V
Sleep Mode:
600 µALogging: 40 to 130 mA

DISPLAY AND KEYPAD
2 line x 20 character LCD display; battery state and external powerindicator; keypad lock
Navigate To: Arm/disarm/pause/continue; meter any channel or alarm;select from up to 6 x pre-storedsetups; status/diagnostics/memory/time and date; download to MMC/SD

OPERATING ENVIRONMENT
Temperature:
-30 to 65°C (-22 to 149°F)
Humidity: 90% at 40°C non-condensing

GENERAL
Power Output for External Device:

Regulated 5 Vdc at 50 mA or logger supply voltage at 100 mA
Time and Date: Built-in clock in 3 formats
Scaling Data: Displays readings in preferred engineering units
Internal Memory: 16 MB (Up to 1,800,000 readings)
External Memory: Up to 1 GB - removable MMC/SD
(for transferring internal memory and storing setups only)
Dimensions: 175 H x 235 W x 95 mm D (6.9 x 9.3 x 3.7")
Weight: Approx. 1.2 kg (2.6 lb)
Enclosure Material: ABS
Memory Modes (Internal Only): Stop when full or overwrite
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors