Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
Product Groups
2-Channel Dynamic Signal-Input Card for OMB-DAQBOARD-2000 Series and OMB-LOGBOOK
TRODEKS Engineering | Thermocouples, Pressure Transducers, Flow Meters, PID Controllers
OMB-DBK4
PLACE ORDER 
  • Offers a Per-Channel Programmable Gain Amplifier for ±50 mV,±500 mV, or ±5 V FS Input
  • Includes a Built-In Current Source for ICP Transducer Biasing
  • Offers Per-Channel Anti-Aliasing Filters
  • Provides Per-Channel Simultaneous Sample and Hold
  • Accommodates Either AC or DC Coupled Signals
  • Both Dynamic Analog Inputs Sampled Within 50 ns of Each Other
 Manuals (contact with email : [email protected])
 Print
Description

Description

The 2-channel OMB-DBK4dynamic signal-input cardenables OMB-LOGBOOKand OMB-DAQBOARD-2000 Seriesdata acquisition systems toaccommodate inputs frompiezoelectric transducers, such asaccelerometers or microphones, aswell as from various other dynamicsignal sources. Each OMB-DBK4card is equipped with two BNCconnectors and footprints for twouser-installed Microdot connectors,permitting it to easily accommodatemost transducer connections.

Architecture
The OMB-DBK4 providesper-channel, constant currentsource outputs, programmablegain amplifiers, programmableanti-aliasing filters, and sampleand hold amplifiers.

Specifications
Channels:
2
Connectors: DB37 male, 1 BNCper channel, and footprints for one
user-provided Microdot connectorper channel
Current Source:
Output Impedance: >1.4 M .
Compliance: 27 V
Current Levels: 2 and 4 mA(jumper selectable)
Input Impedance: 150 K .
Input Ranges:±50 mV, ±500 mV, and ±5 V FS;
additional full scale rangesare available
when combinedwith the OMB-LOGBOOK’s
or OMB-DAQBOARD-2000 Series
on-board programmable A/D ranges
Coupling: AC and DC
AC High-Pass Filters:Per-channel,
1-pole HPF with 10 Hzor 0.1 Hz cutoff,
selectable via jumper
Input Signal/Noise:>96 dB (BW=100 kHz)
Amplitude Accuracy:±0.5 dB passband center
Low-Pass Filter:Software selectable, 12-poleButterworth filter,
with cutofffrequencies of 18 kHz, 9 kHz, 4.5kHz, 2.25 kHz,
1.125 kHz, 562.5 Hz,281.2 Hz, and 141.6 Hz;
eachchannel can be configured for adifferent cutoff frequency
Power Consumption: 2750 mW(When multiple OMB-DBK4 cards
are used, an OMB-DBK32A
auxiliarypower supply may be required.)
Cables:Use OMB-CA-37-x cablewith OMB-LOGBOOK
andOMB-DAQBOARD-2000 Series
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors