4-Channel Frequency-Input Card for OMB-DAQBOARD-2000 Series and OMB-LOGBOOK
TRODEKS Engineering | Thermocouples, Pressure Transducers, Flow Meters, PID Controllers
OMB-DBK7
PLACE ORDER 
  • Programmable from 1 Hzto 950 kHz Per Channel
  • Frequency Resolutionto 0.00025 Hz
  • Provides Per-Channel, User-Configurable Low-Pass Filters
 Manuals (contact with email : [email protected])
 Print
Description

Description

The OMB-DBK7 frequency-inputcard provides OMB-LOGBOOKand OMB-DAQBOARD-2000Series data acquisition systemswith four channels offrequency-measurement capability.Thecard measures the input signal’sfrequency and converts thefrequency to a voltage, whichcan then be measured by thedata acquisition system. TheOMB-DBK7’s output is read by thedata acquisition system along withany other analog channels includedin the analog scan group, allowingeasy correlation of readings fromthe OMB-DBK7 with other testparameters. As many as as sixty-fourOMB-DBK7’s can be connectedto one OMB-LOGBOOK andOMB-DAQBOARD-2000 seriesacquisition system, for a total ofup to 256 channels.

Analog Inputs
The OMB-DBK7 acceptsAC-coupled analog inputs up to80 V p-p. Each of its channels isequipped with a low-pass input filterthat is jumper selectable for 100kHz, 300 Hz, or 30 Hz.The card can accommodate 1 Hz to100 kHz measurement of signalsfrom 50 mV to 80 V p-p.

Digital Inputs
The OMB-DBK7’s digital inputs,which can measure signals from0.001 Hz to 950 kHz, feature TTLSchmitt-trigger levels and can acceptDC-coupled signals from -15 V to+15 V. The OMB-DBK7’s digitalinputs are equipped withpull-up resistors for use with relaysor switches.

Frequency Range
The OMB-DBK7 provides 12-bitresolution at any frequency from1 Hz to 950 kHz.

Update Rates
For ranges from 1 Hz to the user-definedmaximum upper rangeboundary, the voltage conversionupdate will occur every 2 to 4 msor the period of the input frequency,whichever is greater. With a rangeof 0 to 10 kHz, the OMB-DBK7 willupdate every 2 to 4 ms. If the rangeis 0 to 60 Hz, the output will updateevery cycle or 16.6 ms.
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors