Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
Product Groups
16-Channel Differential Input Voltage Card for use with OMB-LOGBOOK and OMB-DAQBOARD-2000 Series
TRODEKS Engineering | Thermocouples, Pressure Transducers, Flow Meters, PID Controllers
OMB-DBK80
PLACE ORDER 
  • 16 Differential Input Channels
  • Unity Gain Combines with OMB-BOARD-2000 Series/OMB-LOGBOOK Gains to Provide Full Scale Inputs from ±156mV to ±10V (±625mV to ±5V)
  • Convenient On-Board Screw Terminal Signal Connection
  • Compact Form Factor Mounts in any OMB-DBK Compatible Enclosure
 Specs
 Manuals (contact with email : [email protected])
 Print
Description

Description

The OMB-DBK80 provides16-channels of differential voltageinput for OMB-DAQBOARD-2000Series and OMB-LOGBOOKmeasurement systems. TheOMB-DBK80 can operate at thefull 100 KHz sample rate with nodegradation of publishedperformance. The OMB-DBK80has a single, unity-gain input stageon all channels.

When coupled with the on-boardx1 through x64 programmableinput gains on the OMB- DAQBOARD-2000Series and OMB-LOGBOOKproduct lines, the combinationprovides full-scale input rangesfrom ± 10V down to ±156mV full-scaleinputs. (±625mV to ±5V when used with OMB-DAQBOARD-2000 Series).

The OMB-DBK80’s ultra-low noisedesign allows users to expandtheir input channels up to 256channels, without incurringadditional noise or inaccuraciesdue to the input expansion cards.Up to 16 OMB-DBK80’s can beattached to one A/D system, andcan also be combined with anyother OMB-DBK series expansionand signal conditioning options.

The OMB-DBK80 also has a +5Vor +10V precision voltage sourceon-board (jumper selectable). Thiscan also be used to bias straingages, thermistors, or othertransducers that require biasing.

Specifications
Connector:
DBK37 male,
mates with P1 pin-out on an
OMB-DAQBOARD-2000 Series
orOMB-LOGBOOK
User Connections: Screw-terminalsfor signal connection
Gain Ranges: 1, x1
Inputs: 16 differential voltage inputs
Maximum Voltage Range: ±10V
Input Impedance: 20M ohm
Accuracy: +0.025% + 150 µV (typ),
+ 0.1% +250 µV (max)
Maximum Input Voltage
(withoutdamage):
35V
3dB Bandwidth: 2.6 M Hz
CMRR: 80dB
Excitation Voltage:
One channeljumper selectable to +5V or +10V
Excitation Voltage Accuracy:+0.5%
Excitation Voltage Current Limit:
20 mA source, 1 mA sink
Power: 25 mA max from +15V
(with no load on excitation voltage)
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors