Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
DC and AC Current Input Signal Conditioners
DRF-IDC and DRF-IAC
PLACE ORDER - AC/DC Current Input Ranges from 0 to 100 mA to 0 to 5 A
- Accuracy 0.3%
- Response Time for DC Signals, 70 ms
- Response Time for AC Signals, 250 ms
- Ranges for x5 and x1 Current Transformers
- Low Impedance Current Inputs
- Galvanic Isolation between Input, Output and Power
Description
Description
The DRF series DIN rail signal conditioners aredesigned to accept a broad range of input signals,such as ac and dc voltage and current, frequency,temperature (thermocouple and RTD), and processtransducers, and provide standard process outputsof either 4 to 20 mA, or 0 to 10 Vdc. The DRF seriesfeature a modern housing design, that is easilymounted on standard 35 mm DIN rails. Connectionsare safely and securely made through pluggablescrew terminal connectors, with input and outputconnections on the opposite sides of the module.
The DRF-IDC and the DRF-IACcurrent signal conditioners acceptdc and ac currents respectivelyand provide an isolated 0 to 10 Vdcor 4 to 20 mA output. Models areavailable with three different poweroptions, 24 Vdc, 120 Vac and240 Vac.The DRF-IDC and DRF-IACare ideally suited for industrialapplications. All models mounton a standard 35 mm DIN railand provide galvanic isolationbetween input, output and powerup to 3500 Veff (model specific).
Range Code Table
Range Code | DRF IDC Range | DRF IAC Range |
100MA | 0 to 100 mAdc | 0 to 100 mAac |
200MA | 0 to 200 mAdc | 0 to 200 mAac |
300MA | 0 to 300 mAdc | 0 to 300 mAac |
1A | 0 to 1 Adc | 0 to 1 Aac |
2A | 0 to 2 Adc | 0 to 2 Aac |
3A | 0 to 3 Adc | 0 to 3 Aac |
5A | 0 to 5 Adc | 0 to 5 Aac |
SPECIFICATIONS
Accuracy: <0.3% full scale Linearity: <0.2% full scale Thermal Drift: 250 ppm/°C typical (max <200ppm/°C) Response Time(90% of signal) DC Signal Input Models: < 70mS at 20Hz -3dB AC SignalInput Models: <250mS Maximum AC Frequency: 1 KHz Input Impedance: 1Ω for ranges<5 A, 0.02 Ω for ranges <1 A Over Range Protection: 7.5 A forranges greater than 500 mA andless than or equal to 5 A, 750 mAfor ranges less than and equal to500 mA
Power: 24 Vdc ±10%, 230 Vac ±10% 50/60 Hz,115 Vac ±10% 50/60 Hz Power Consumption: <3.8 VA
| |
Output: 4 to 20 mA and 0 to 10 Vdc Maximum Voltage Output: 11 Vdc approx. Minimum Voltage Output: -1 Vdc approx. Minimum Load Resistance (Voltage): >1 KΩMaximum Current Output: 22 mA approx. Maximum Current Output: -1.5 mA approx. Maximum Load Resistance (current): >400 Ω Electrical Connections: Plug-in screw terminals Protection: IP-30
MECHANICAL DIMENSIONS Weight: (DC Powered Models): 120 g (4.2 oz) (AC Powered Models): 200 g (7 oz) Dimensions: (DC Powered models): 110 H x 22.5 W x 93 mm D (4.3 x 0.9 x 3.7") (AC Powered models): 110 H x 37 W x 93 mm D (4.3 x 1.46 x 3.7") Operating Temperature: 0 to 60°C (32 to 140°F) Storage Temperature: -20 to 70°C (-4 to 158°F) |
Anemometer | Automation | Accelerometers | Calibrator | Cartridge Heaters | Chart Recorders | Cryogenics | Custom Pressure Transducers | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Fiber Optic Temperature Measurement | Flexible Heaters | Flow Meters | Glass Bulb Thermometers | Grippers | Heaters | Humidity Measurement | Integrated Circuit Sensors | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells | M12 Temperature Connectors | Magnetic Flow Meter | Panel Meter | PID Controllers | pH meter | Pressure Gauges | Pressure Transducers | Pressure Transmitters | Rotameters | RTD | Remote Process Monitoring | Sanitary Sensors | Signal Conditioners | Stepper Motors | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Sensor Manufacturing | Temperature Sensors | Temperature Transmitters | Thermal Imagers | Thermistors | Thermocouple | Thermocouple Wire | Thermowell | Ultrasonic Flow Meters | Vortex Flow Meter | Wireless Sensors