Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
RTD Input Signal Conditioner
DRF-RTD Series
PLACE ORDER - 100 Ω Platinum (Pt) RTD Element, 0.00385 Curve
- 2 or 3 Wire Configuration
- 0.2% Accuracy
- Cable Resistance Compensation up to 10 Ω
- Upscale Break Protection
- Response Time < 250 mS
- Galvanic Isolation Between Input, Output and Power
Description
Description
The DRF series DIN rail signal conditioners aredesigned to accept a broad range of input signals,such as ac and dc voltage and current, frequency,temperature (thermocouple and RTD), and processtransducers, and provide standard process outputsof either 4 to 20 mA, or 0 to 10 Vdc. The DRF seriesfeature a modern housing design, that is easilymounted on standard 35 mm DIN rails. Connectionsare safely and securely made through pluggablescrew terminal connectors, with input and outputconnections on the opposite sides of the module.
The DRF-RTD RTD signalconditioners accept 2 or 3 wire100 platinum RTDs as input andprovide an isolated 0 to 10 Vdcor 4 to 20 mA output. Models areavailable with three different poweroptions,
24 Vdc, 120 Vac and240 Vac.
The DRF-RTD are ideally suited forindustrial applications. All modelsmount on a standard 35 mm DINrail and provide galvanic isolationbetween input, output and powerup to 3500 Veff (model specific).Module response time is 250 mSor less.
Range Code Table for DRF-RTD
Range Code | Range |
-25/75C | -25 to 75°C |
0/100C | 0 to 100°C |
0/200C | 0 to 200°C |
0/300C | 0 to 300°C |
0/450C | 0 to 450°C |
0/600C | 0 to 600°C |
SPECIFICATIONS
RTD: 2 or 3 wire 100Ω platinum RTD: α=0.00385 Accuracy: <0.2% full scale Linearity: <0.1% full scale Thermal Drift: 250 ppm/°C typical Response Time: <250 mS (90% of signal) RTD Excitation: 1 Vdc Input Impedance: Measuredwith a "Wheatstone" bridge. Bridgeto positive through a 100 .resistance, Bridge to negativethrough a 10 KΩ resistance
Power: 24 Vdc ±10%, 230 Vac ±10% 50/60 Hz,115 Vac ±10% 50/60 Hz Power Consumption: <3.8 VA Output: 4 to 20 mA and 0 to 10 Vdc
| |
Maximum Voltage Output: 11 Vdc approx. Minimum Voltage Output: -1 Vdc approx. Minimum Load Resistance (Voltage): >1 KΩMaximum Current Output: 22 mA approx. Maximum Current Output: -1.5 mA approx. Maximum Load Resistance (current): >400 Ω
Electrical Connections: Plug-in screw terminals Protection: IP-30
MECHANICAL DIMENSIONS Weight: (DC Powered Models): 120 g (4.2 oz) (AC Powered Models): 200 g (7 oz) Dimensions: (DC Powered models): 110 H x 22.5 W x 93 mm D (4.3 x 0.9 x 3.7") (AC Powered models): 110 H x 37 W x 93 mm D (4.3 x 1.46 x 3.7") Operating Temperature: 0 to 60°C (32 to 140°F) Storage Temperature: -20 to 70°C (-4 to 158°F) |
Anemometer | Automation | Accelerometers | Calibrator | Cartridge Heaters | Chart Recorders | Cryogenics | Custom Pressure Transducers | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Fiber Optic Temperature Measurement | Flexible Heaters | Flow Meters | Glass Bulb Thermometers | Grippers | Heaters | Humidity Measurement | Integrated Circuit Sensors | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells | M12 Temperature Connectors | Magnetic Flow Meter | Panel Meter | PID Controllers | pH meter | Pressure Gauges | Pressure Transducers | Pressure Transmitters | Rotameters | RTD | Remote Process Monitoring | Sanitary Sensors | Signal Conditioners | Stepper Motors | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Sensor Manufacturing | Temperature Sensors | Temperature Transmitters | Thermal Imagers | Thermistors | Thermocouple | Thermocouple Wire | Thermowell | Ultrasonic Flow Meters | Vortex Flow Meter | Wireless Sensors