PLACE ORDER 
  • Wireless Two-Way Communications
  • 20 mA, 160 mA, or 3 A Measurement Ranges
  • Digital Display Provides Instant Access to Current Readings and Statistics
  • Readings Displayed in User Selected Measurement Unit
  • Configurable Alarms
  • 4 Year Battery Life at 15 Minute Reading Rate
  • Battery Life Indicator
 Manuals (contact with email : [email protected])
 Print
Description

Description

The OM-CP-RFCURRENT2000A is a wireless datalogger with a digital display, designed to measure andrecord DC current signals. This data logger can connectdirectly to low-level DC current sources which makeit ideal for battery usage studies, energy monitoringstudies and other DC current monitoring applications.

The OM-CP-RFCURRENT2000A can also be interfacedwith a wide range of current output sensors suchas flow meters, pH transmitters and more. Throughthe software, the device can be programmed withengineering units, which convert the current readingsinto a different unit of measure such as flow rate. Theengineering unit is available for display on the LCDscreen as well as in the software. TheOM-CP-RFCURRENT2000A is available in 20 mA,160 mA or 3 A measurement ranges.

The OM-CP-RFCURRENT2000A features an LCDscreen which provides instant access to the currentreading, minimum, maximum and average statistics.The statistics can be reset through the keypad of thedevice, allowing customers to keep track of statisticsover certain time periods. This feature does not erasethe data recorded, but only resets the statistics count.The OM-CP-RFCURRENT2000A can be used as astandalone data logger, or used with theOM-CP-RFC1000-EXT wireless transceiver, to transmitdata back to a central PC.

The OM-CP-RFCURRENT2000A transmits up to152 m (500') line of sight to the OM-CP-RFC1000-EXTtransceiver. Multiple OM-CP-RFC1000-EXT’s can beused as repeaters and transmit up to 305 m (1000') lineof sight to other OM-CP-RFC1000-EXT’s. This allowsthe data to be sent over a greater distance.

The OM-CP-RFCURRENT2000A can be usedas a single, wireless data logging system, or canbe expanded to a large scale system, which caninclude hundreds of data loggers measuring differentparameters such as temperature, humidity and more(additional wireless data loggers and transceivers maybe required). The OM-CP-RFCURRENT2000A utilizesthe latest software. Data can be viewed in graphical ortabular formats and summary and statistics views areavailable for further analysis. The software featuresexport to Excel®, data annotation, digital calibrationand more.

SPECIFICATIONS
WIRELESS
RF Frequency: 2.45GHz IEEE 802.15.4 ultra-low power wireless transceiver with fully bi-directional communication
Band: ISM band 2.405-2.475 GHz Operation (channels 11 through 25) @ 250 kbps data rate
Transceiver Sensitivity (OM-CP-RFC1000-EXT): -95dBm typical
Transmission Distance (to other OM-CP-RFC1000-EXT’s)
    OM-CP-RFC1000-EXT, OM-CP-RFC1000-IP69K:
    Maximum Outdoors: 1220 m (4000') (line of sight unobstructed)
    Maximum Indoors: 305 m (1000') (typical urban environment)
    OM-CP-RFC1000-EXT-EUR:
    Maximum Outdoors: 762 m (2500') (line of sight unobstructed)
    Maximum Indoors: 213 m (700') (typical urban environment)
Transmission Distance (to Data Loggers)
    OM-CP-RFC1000-EXT, OM-CP-RFC1000-EXT-EUR, OM-CP-RFC1000-IP69K:
    Maximum Outdoors: 610 m (2000') (line of sight unobstructed)
    Maximum Indoors: 152 m (500') (typical urban environment)
GENERAL
Reading Rate: 1 reading every second up to 1 reading every 24 hours
Memory: 32,256 readings
Memory Wrap Around: Yes
Start Modes: Immediate start and delayed start
Stop Modes: Manual through software Delayed Stop Timed (specific date and time)
Real Time Recording: The device may be used with PC to monitor and record data in real-time
Alarm: User configurable audible, on-screen, email and text (SMS) alarms
Alarm Delay: A cumulative alarm delay may be set in which the device will activate the alarm (via LED) only when the device has recorded a user specified time duration of data
Audible Alarm Functionality: 1 beep per second for reading alarm above/below threshold
LED Functionality:
    Green LED: blinks every 10 seconds to indicate unit is logging
    Blue LED: blinks every 30 seconds to indicate unit is in wireless mode
    Red LED: blinks every 1 second to indicate alarm condition
Password Protection: An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password.
Engineering Units: Native measurement units can be scaled to display measurement of units of another type. This is useful when monitoring current outputs from different types sensors such as temperature, flow rate and more.
Calibration: Digital calibration through software.
Calibration Date: Automatically recorded through the device
Battery Type: 9V lithium battery (included); user replaceable
Battery Life: 4 years typical at 15 minute reading rate
Data Format: µA, mA, A
Time Accuracy: ±1 minute/month
Computer Interface: USB to mini USB, 250,000 baud for standalone operation or OM-CP-RFC1000-EXT/ OM-CP-RFC1000-EXT-EUR/OM-CP-RFC1000-IP69K required for wireless operation
Software: XP SP3/Vista/7 and 8 (32-bit and 64-bit)
Operating Environment: -20 to 60°C (-4 to 140°F), 0 to 95% RH non-condensing
Dimensions: 82.6 H x 88.9 W x 24.1 mm D (3.3 x 3.5 x 0.95") data logger only
Weight: 116 g (4.1 oz)
Enclosure Material: ABS plastic
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors