Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
Wireless Pulse Data Logger with Display
OM-CP-RFPULSE2000A
PLACE ORDER - Wireless Two-Way Communication
- Pulse Input for Monitoring Wind Speed, Energy or Flow Rate
- View Data in Real Time
- Battery Life Indicator
- Digital Display
- 3 Year Battery Life
- Audible and LED Alarm Indicators
- Configurable Alarms
Description
Description
The new OM-CP-RFPULSE2000A is a wirelessdata logger that records pulse output signalsfrom various sensors such as flow meters andanemometers. When started, the data loggersamples at 100 Hz and at the user specifiedreading rate, recording the total number ofpulses from the sample to memoryThe OM-CP-RFPULSE2000A features anLCD screen which provides instant access to thecurrent reading, minimum, maximum and averagestatistics. Through the software the device can beprogrammed to convert the pulse output into a differentunit of measure such as gallons per minute or milesper hour. This information can be viewed on the LCDscreen of the data logger as well as inthe software.The OM-CP-RFPULSE2000A is unique in that it notonly calculates pulse count, but it also calculates pulserate. Engineering units can be programmed into thedevice as a rate, which allows the device to calculatethe measurement unit in rates per second, minute, houror per day. This provides more useful statistics to theuser when data logging over long periods of time.The OM-CP-RFPULSE2000A can be used as astandalone data logger, or it can be used with theOM-CP-RFC1000-EXT wireless transceiver towirelessly transmit data back to a central PC. TheOM-CP-RFPULSE2000A transmits up to 152 m (500')line of sight to the OM-CP-RFC1000-EXT transceiver.Multiple OM-CP-RFC1000-EXT’s can be used asrepeaters and transmit up to 305 m (1000') line of sightto other OM-CP-RFC1000-EXT’s. This allows the datato be sent back over a greater distance.The OM-CP-RFPULSE2000A can be used as a single,wireless data logging system, or can be expanded toa large scale system, which can include hundreds ofdata loggers measuring a number of areas (additionalwireless loggers and transceivers may be required).Data can be viewed in graphical or tabular formats andsummary and statistics views are available for furtheranalysis. The software features export to Excel®, dataannotation, digital calibration and more.
SPECIFICATIONS
PULSE INPUT
Measurement:
Maximum Pulse Rate: 10 KHz
Range: Input low <720 mV, input high >1.070V
Resolution: ≤10 µS
Calibrated Accuracy: 512 ±1 pulses per second
Response Time: 10 µS
WIRELESS
RF Frequency: 2.45GHz IEEE 802.15.4 ultra-low power wireless transceiver with fully bi-directional communication
Band: ISM band 2.405 to 2.475 GHz operation (channels 11 through 25) @ 250 kbps data rate
Transceiver Sensitivity (OM-CP-RFC1000-EXT): -95dBm typical
Transmission Distance (to other OM-CP-RFC1000-EXT’s):
OM-CP-RFC1000-EXT, OM-CP-RFC1000-IP69K:
Maximum Outdoors: 1220 m (4000') (line of sight unobstructed)
Maximum Indoors: 305 m (1000') (typical urban environment)
OM-CP-RFC1000-EXT-EUR:
Maximum Outdoors: 762 m (2500') (line of sight unobstructed)
Maximum Indoors: 213 m (700') (typical urban environment)
Transmission Distance (to Data Loggers):
OM-CP-RFC1000-EXT, OM-CP-RFC1000-EXT-EUR,
OM-CP-RFC1000-IP69K:
Maximum Outdoors: 610 m (2000') (line of sight unobstructed)
Maximum Indoors: 152 m (500') (Typical urban environment)
General
Reading Rate: 1 reading every second up to 1 reading every 24 hours
Memory: 16,128 readings
LED Functionality:
• Green LED blinks every 5 seconds to indicate unit is logging
• Blue LED blinks every 15 seconds to indicate unit is in wireless mode
• Red LED blinks every 1 second to indicate alarm condition
Memory Wrap Around: Yes
Start Modes: Immediate start and delayed start
Battery Type: 9V lithium included; user replaceable
Battery Life: 3 years typical at 15 minute reading rate
Display Details: Displays pulse/interval count and total count
Time Accuracy: ±1 minute/month
Computer Interface: USB to mini USB, 250,000 baud for standalone operation or OM-CP-RFC1000-EXT/ OM-CP-RFC1000-EXT-EUR/OM-CP-RFC1000-IP69K required for wireless operation
Software: XP SP3/Vista/7 and 8 (32- and 64-bit)
Operating Environment: -20 to 60°C (-4 to 140°F) 0 to 95% RH non-condensing
Dimensions: 76.2 H x 88.9 W x 24.1 D mm (3.0 x 3.5 x 0.95") data logger only
Weight: 116 g (4.1 oz)
Enclosure Material: ABS plastic
Alarm: User configurable audible, on-screen, email and text (SMS) alarms
Alarm Delay: A cumulative alarm delay may be set in which the device will activate the alarm (via LED) only when the device has recorded a user specified time duration of data
Audible Alarm Functionality: 1 beep per second for reading alarm above/below threshold Anemometer | Automation | Accelerometers | Calibrator | Cartridge Heaters | Chart Recorders | Cryogenics | Custom Pressure Transducers | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Fiber Optic Temperature Measurement | Flexible Heaters | Flow Meters | Glass Bulb Thermometers | Grippers | Heaters | Humidity Measurement | Integrated Circuit Sensors | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells | M12 Temperature Connectors | Magnetic Flow Meter | Panel Meter | PID Controllers | pH meter | Pressure Gauges | Pressure Transducers | Pressure Transmitters | Rotameters | RTD | Remote Process Monitoring | Sanitary Sensors | Signal Conditioners | Stepper Motors | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Sensor Manufacturing | Temperature Sensors | Temperature Transmitters | Thermal Imagers | Thermistors | Thermocouple | Thermocouple Wire | Thermowell | Ultrasonic Flow Meters | Vortex Flow Meter | Wireless Sensors
trodeks.comtrodeks.com - فقخیثنس.زخئ - صصص.فقخیثنس.زخئ