Heavy Duty Electropneumatic ConvertersI-P and E-P Models
IP510, EP510, IP511, EP511 Series
PLACE ORDER - Hazardous Locations and Intrinsically Safe Ratings
- NEMA 4X (IP65)
- 0.1% Accuracy Typical
- Closed Loop Pressure Feedback Control
- Built-in Volume Booster Provides Flow Up to 12 SCFM
- Easy Access to Zero and Span
- Damping Pot Prevents Overshoot and Hunting
- Low Air Consumption
- Mount at Any Angle
- Compact and Lightweight
- Virtually No Sensitivity to Supply Pressure Changes
- Removable Orifice for Easy Maintenance
- Buna-N Seals Standard, Fluorocarbon Optional
Description
Description
The IP510/EP510 Series are a patented family of electro-pneumaticinstruments that are used to reduce a pneumatic supply pressure to a regulated output pressure which is directly proportional to a two-wire current or three-wire voltage input. This design incorporates closed loop sensing of the output pressure to achieve excellent accuracy and vibration stability. They also feature a unique damping circuit which can be adjusted to prevent overshoot and actuator hunting. Model selection includes General purpose NEMA 1, and Water-tight/Corrosion Resistant NEMA 4X (IP65). All models carryHazardous Locations and intrinsically safe ratings.
SPECIFICATIONS
Accuracy:
Typical: ±0.1% of output span
Max: ±0.25% of output span
Hysteresis:
Typical: ±0.01% of output span
Max: ±0.10% of output span
Deadband: No effect
Repeatability:
Typical: ±0.01% of output span
Max: ±0.10% of output span
Ambient Temperature Effect Zero:
Typical: ±0.004% of nominal span/°F
Max: ±0.022% of nominal span/°F
Ambient Temperature Effect Span:
Typical: 0.013% of calibrated span/°F
Max: 0.022% of calibrated span/°F
Temperature Effect: ≤0.02%/°F, zero and span effects combined
Operating Temperature Range:
Buna-N Elastomers: -29 to 71°C (-20 to 160°F)
Fluorocarbon Elastomers: -18 to 71°C (0 to 160°F)
Storage Temperature Range:
Buna-N Elastomers: -40 to 93°C (-40 to 200°F)
Fluorocarbon Elastomers: -26 to 93°C (-15 to 200°F)
Vibration Effects: Less than 0.5% of span per 1 g, 5 to 2000 Hz, 3 g max, 3 axes
Mounting Position Effect: Not measurable
Loop Load, I/P Transducer:
Less than 10 Vdc drop at 20 mA
Less than 12 Vdc drop at 50 mA
Supply Voltage, E/P Transducer:
Intrinsically Safe/Non-Incendive: 9 to 28 Vdc, less than 20 mA
General Purpose: 9 to 40 Vdc, less than 20 mA
Supply Voltage Effect: No effect
Signal Impedance E/P Transducer: 6000 &trodeks; minimum
RFI/EMI Effect NEMA 4X (IP66): Less than 0.25% of span change in output 10 V/meter, 20 to 1000 MHz (Reference SAMA PML 33.1 to 1978, 2 to abc)
Supply Pressure Sensitivity: No effect
Effective Air Consumption: 0.07 SCFM (2 LPM) maximum
Supply Pressure: 100 psig (6.9 bar) maximum*
* For models with zero output capability maximum supply pressure = 40 psi (2.8 bar) above maximum output, except for 0 to 100 and 0 to 120 psi models that have a maximum supply pressure of 130 psi (9 bar) and 140 psi (9.7 bar) respectively.
Dimensions
IP510: 102 H x 48 W x 89 mm D (4.01 x 1.88 x 3.5")
IP511: 144 H x 112 mm W (5.66 x 4.36")
Port Sizes:
Pneumatic: ¼ FNPT
Electrical: ½ FNPT Anemometer | Automation | Accelerometers | Calibrator | Cartridge Heaters | Chart Recorders | Cryogenics | Custom Pressure Transducers | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Fiber Optic Temperature Measurement | Flexible Heaters | Flow Meters | Glass Bulb Thermometers | Grippers | Heaters | Humidity Measurement | Integrated Circuit Sensors | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells | M12 Temperature Connectors | Magnetic Flow Meter | Panel Meter | PID Controllers | pH meter | Pressure Gauges | Pressure Transducers | Pressure Transmitters | Rotameters | RTD | Remote Process Monitoring | Sanitary Sensors | Signal Conditioners | Stepper Motors | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Sensor Manufacturing | Temperature Sensors | Temperature Transmitters | Thermal Imagers | Thermistors | Thermocouple | Thermocouple Wire | Thermowell | Ultrasonic Flow Meters | Vortex Flow Meter | Wireless Sensors