Molded Case Circuit Breakers
EGB3000
PLACE ORDER - Small and Compact
- 15 to 100 Amp Models Available
- Quality Thermal Magnetic Circuit Breakers
Description
Description
Series G molded case circuit breakersprovide increased performance inconsiderably less space than standard circuitbreakers or comparable fusible devices. The"G" signifies global applications: Series Gcircuit breakers are marked with UL, CSA,CE, IEC and KEMA, KEUR listings.
The EG frames are designed around spacesavingfootprints. Series G circuit breakersmeet applicable UL 489 and IEC 60947-2standards. The G family includes five framesizes in ratings from 15 to 100 amperes.Series G offers a choice of severalinterrupting capacities up to 18 kA at 415and 480 Vac. Standard calibration is 40°C.
The flexibility and outstanding performancecharacteristics of the circuit breakers aremade possible by the best contact designs incircuit breaker history. Our technologycreates a high-speed "blow-open" actionusing the electromechanical forces producedby high-level fault currents.
These circuit breakers are operated by atoggle-type mechanism that is mechanicallytrip-free from the handle so that the contactscannot be held closed against short circuitcurrents. Tripping due to overload or shortcircuits is clearly indicated by the position onthe handle. This remarkably fast anddependable contact action is designed toenhance safety.
The quality, dependability and reliability ofevery circuit breaker is ensured by athorough program of in-plant testing. Twocalibration tests are conducted on every poleof every circuit breaker to verify the tripmechanism, operating mechanism,continuity and accuracy.
Circuit breakers are current limiting becauseof their high repulsion contact arrangementand use of state-of-the-art arc extinguishingtechnology. trodeks offers one of the mostcomplete lines of current limiting breakers inthe industry.
Circuit Breakers have a toggle handleoperating mechanism, which also servesas a switching position indicator. Theindicator shows the positions of: ON, OFFand TRIPPED.
The toggle handle snaps into the TRIPPEDposition if the breaker is tripped by one of itsovercurrent, short circuit, shunt orundervoltage releases. Before the circuitbreaker can be reclosed following a trip-out,the toggle handle must be brought beyondthe OFF position (RESET). The circuitbreaker can then be reclosed.
As an additional switching position indicatorfor EG- Frame circuit breakers, there are twowindows on the right and on the left of thetoggle handle, in which the switching state isindicated by means of the colors red, greenand white corresponding to the ON, OFF andTRIPPED positions respectively.
SPECIFICATION
Number of Poles: 3
BREAKER CAPACITY (KA RMS) AC 50 TO 60 HZ NEMA, UL, CSA:
240 Vac: 25
480 Vac: 18
IEC60947-2:
Icu 220 to 240 Vac: 25
Icu 380 to 425 Vac: 18
Ampere Range: 15 to 100 A
Trip Units: FT-FM (fixed thermal - fixed magnetic)
Dimensions: 139.7 H x 76.2 W x 76mm D (5.5 x 3.0 x 2.9")
Weight: 1.4 kg (3.1 lbs)
Utilization Category: A
ELECTRICAL CHARACTERISTICS
Maximum Rated Current: 100 A
Rated Insulation Voltage U, According to IEC 60947-2: Main Conducting Paths: 690 Vac
Auxiliary Circuits: 690 Vac
Rated Impulse Withstand Voltage Uimp:
Main Conducting Paths: 6 kV
Auxiliary Circuits: 4 kV
Rated Operational Voltage Ue:
IEC: 690 Vac
NEMA: 600 Y/347 Vac
UL and CSA Listed: Yes
Permissible Ambient Temperature: -20 to 70°C (-4 to 158°F)
PERMISSIBLE LOAD FOR VARIOUS AMBIENT TEMPERATURES CLOSE TO THE CIRCUIT BREAKER, RELATED TO THE RATED CURRENT OF THE CIRCUIT BREAKER:
Circuit Breakers for Plant Protection: |
---|
| Thermal overload release set to the lower value | Thermal overload release set to the upper value |
At 40°C: | 100% | 100% |
---|
At 50°C: | 96% | 92% |
---|
At 55°C: | 93% | 87% |
---|
At 60°C: | 91% | 83% |
---|
At 70°C: | 86% | 73% |
---|
Circuit Breakers for Starter Combinations and Isolating Circuit Breakers: |
---|
At 40°C: | 100% |
---|
At 50°C: | 100% |
---|
At 55°C: | 96% |
---|
At 60°C: | 91% |
---|
At 70°C: | 86% |
---|
RATED SHORT CIRCUIT BREAKING CAPACITY (DC) NOT FOR CIRCUIT BREAKERS FOR MOTOR PROTECTION (TIME CONSTANT = 10 RMS):
2 Conducting Paths in Series:
For EG up to 250 Vdc: 42 kA Max
NEMA (Time Constant = 8 rms) 2 Conducting Paths in Series: 250 Vdc 42 kA Max
Main Switch Characteristics According to IEC 60947-2 in Combination with Lockable Rotary Drives: Yes
Rated Short Circuit Breaking Capacity According to IEC 60947-2 (at AC 50/60 hz): Rated short circuit breaking capacity
Endurance (Operating Cycles): 10,000
Maximum Switching Frequency: 300 1/h
Conductor Cross Sections and Terminal Types for Main Conductors: Box Terminals
Solid or Stranded: 2.5 to 95 mm2
Finely Stranded with End Sleeve: 2.5 to 50/70 mm2
Tightening Torque for Box Terminals: 5.6 Nm
Tightening Torque for Bus Bar Connection Pieces: 5.6 Nm
CONDUCTOR CROSS SECTIONS FOR AUXILIARY CIRCUITS WITH TERMINAL CONNECTION OR TERMINAL STRIP
Solid or Finely Stranded with End Sleeve: 0.75 to 2.5 mm2
POWER LOSS PER CIRCUIT BREAKER AT MAXIMUM RATED CURRENT LN (THE POWER LOSSES OF THE UNDERVOLTAGE RELEASES ("R" RELEASES) MUST BE OBSERVED IF NECESSARY) AT THREE-PHASE SYMMETRICAL LOAD)
For Plant Protection, As Isolating Circuit Breaker, For Starter Combinations: 40 W
AUXILIARY SWITCHES
Rated Thermal Current lth: 6 A
Rated Making Capacity AC (AC-15): 20 A
Rated Operational Voltage: 230/400/600V
Rated Operational Current DC (DC-13): 6/3/0.25 A
Rated Operational Voltage: 125/250V
Rated Operational Current: 0.5/0.25 A
Backup Fuse: 6/4/4 A
Miniature Circuit Breaker: 6/4 A
RELEASES
Undervoltage releases ("r" Releases) Response Voltage:
Drop (Breaker Tripped) Us: 35 to 70%
Pickup (Breaker May Be Switched On) Us: 85 to 110%
Power Consumption in Continuous Operation at:
50/60 Hz 12 Vac: 0.95 VA
50/60 Hz 24 Vac: 0.72 VA
50/60 Hz 48 to 60 Vac: 1.15 to 1.78 VA
50/60 Hz 110 to 127 Vac: 0.96 to 1.25 VA
50/60 Hz 208 to 240 Vac: 1.28 to 1.68 VA
50/60 Hz 380 – 500 Vac: 2.2 to 3.9 VA
12 Vdc: 0.88 W
24 Vdc: 0.70 W
48 to 60 Vdc: 1.12 to 1.76 W
110 to 125 Vdc: 0.94 to 1.21 W
220 to 250 Vdc: 1.45 to 1.86 W
Maximum Opening Time: 50 ms
SHUNT TRIPS
Shunt Trips ("f" Releases) Response Voltage:
Pickup (Breaker Tripped) Us Power Consumption in (Short Time) at:
50/60 Hz 24 Vac: 10 to 41 VA
50/60 Hz 48 to 60 Vac: 139 to 210 VA
50/60 Hz 48 to 127 Vac: N/A
50/60 Hz 110 to 240 Vac: 83 to 360 VA
50/60 Hz 380 to 440 Vac: N/A
50/60 Hz 380 to 600 Vac: 418 to 1080 VA
12 to 24 Vdc: 29 to 120 W
48 to 60 Vdc: 475 to 720 W
110 to 125 Vdc: 99 to 121 W
220 to 250 Vdc: N/A
Maximum Load Duration: Interrupts automatically
Maximum Opening Time: 50 ms Anemometer | Automation | Accelerometers | Calibrator | Cartridge Heaters | Chart Recorders | Cryogenics | Custom Pressure Transducers | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Fiber Optic Temperature Measurement | Flexible Heaters | Flow Meters | Glass Bulb Thermometers | Grippers | Heaters | Humidity Measurement | Integrated Circuit Sensors | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells | M12 Temperature Connectors | Magnetic Flow Meter | Panel Meter | PID Controllers | pH meter | Pressure Gauges | Pressure Transducers | Pressure Transmitters | Rotameters | RTD | Remote Process Monitoring | Sanitary Sensors | Signal Conditioners | Stepper Motors | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Sensor Manufacturing | Temperature Sensors | Temperature Transmitters | Thermal Imagers | Thermistors | Thermocouple | Thermocouple Wire | Thermowell | Ultrasonic Flow Meters | Vortex Flow Meter | Wireless Sensors