Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
Universal Thermocouple Connector Direct USB to PC Connection
UTC-USB
PLACE ORDER - For J, K, T, E, R, S, B, C and N Thermocouples
- Built-In Cold Junction Compensation and Linearization
- Accepts Both Standard and Miniature Connectors
- Free Downloadable Software for Display, Data Logging and Chart Recording
Description
Description
Type | Range, °C | Range, °F | Accuracy |
---|
J | -100 to 760°C | -148 to 1400°F | ±0.5% rdg or ±1°C (1.8°F)* |
K | -100 to 1260°C | -148 to 2300°F | ±0.5% rdg or ±1°C (1.8°F)* |
T | -200 to 400°C | -328 to 752°F | ±0.5% rdg or ±2°C (3.6°F)* |
E | -200 to 1000°C | -328 to 1832°F | ±0.5% rdg or ±2°C (3.6°F)* |
R | 260 to 1760°C | 500 to 3200°F | ±0.5% FS |
S | 260 to 1760°C | 500 to 3200°F | ±0.5% FS |
B | 870 to 1820°C | 1598 to 3308°F | ±0.5% FS |
C | 0 to 2315°C | 32 to 4199°F | ±0.5% FS |
N | -100 to 1260°C | -148 to 2300°F | ±0.5% rdg or ±2°C (3.6°F)* |
The new UTC-USB universalthermocouple connector accepts thesignal from any of 9 thermocoupletypes, and lets you display actualtemperature readings on your PC,through a standard USB port. TheUTC-USB provides automatic coldjunction compensation andlinearization; the included softwarelets you select the thermocoupletype and units, and then use yourPC as a meter, chart recorder ordata logger.
The UTC-USB features trodeks’spatented universal input connection,so you can quickly attach bothstandard and miniature sizethermocouple connectors. Astandard USB cable is included forfast hook-up to your PC.
SPECIFICATIONS
Thermocouple (TC) Input User Selectable: J, K, T, E, R, S, B, C or N
Measurement Accuracy:
Type J, K: ±0.5% of reading or ±1.0°C (1.8°F), whichever is greater
Type T, E, N: ±0.5% of reading or ±2.0°C (3.6°F), whichever is greater
Type R, S, B, C: ±0.5% of full scale
Measurement Resolution: 1°C (1°F) Cold Junction Compensation
(Automatic): -10 to 70°C (14 to 158°F)
Thermocouple Connection: Patented universal female accepts both standard or miniature male connector
USB Connection: Version 1.0, 1.1 and 2.0 compatible; mini-B connector; 1.8 m (6') cable included
Operating Environment: -10 to 70°C (14 to 158°F)
Computer Interface: USB (one interface cable included with receiver)
Software (Included Free): Compatible with Windows® 2000, XP, Vista (32 bit) or Win7 (64 bit) operating system
Dimensions: 76 L x 25.4 W x 13 mm H (3 x 1 x 0.5")
Enclosure: Plastic (glass filled nylon) Anemometer | Automation | Accelerometers | Calibrator | Cartridge Heaters | Chart Recorders | Cryogenics | Custom Pressure Transducers | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Fiber Optic Temperature Measurement | Flexible Heaters | Flow Meters | Glass Bulb Thermometers | Grippers | Heaters | Humidity Measurement | Integrated Circuit Sensors | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells | M12 Temperature Connectors | Magnetic Flow Meter | Panel Meter | PID Controllers | pH meter | Pressure Gauges | Pressure Transducers | Pressure Transmitters | Rotameters | RTD | Remote Process Monitoring | Sanitary Sensors | Signal Conditioners | Stepper Motors | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Sensor Manufacturing | Temperature Sensors | Temperature Transmitters | Thermal Imagers | Thermistors | Thermocouple | Thermocouple Wire | Thermowell | Ultrasonic Flow Meters | Vortex Flow Meter | Wireless Sensors
trodeks.comtrodeks.com - فقخیثنس.زخئ - صصص.فقخیثنس.زخئ