Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
4-IN-1 Air Velocity Meter - Anemometer- Hygrometer- Light Meter- Thermometer
HHF81
PLACE ORDER - Simultaneous Readings of Air Velocity and Temperature or Humidity and Temperature
- Exclusive Photo Diode and Color Correction Filter Light Sensor, Spectrum Meets C.I.E. Photopic
- Standard Type K Thermocouple SMP Input Jack Suitable for All Types of K Probes
- Lux/Feet-Candle Selectable by Pressing Button on the Front Panel
Description
Description
The HHF81 anemometer can measure air flow, humidity, temperature and light. The built-in microprocessor circuit assuresexcellent performance and accuracy. The HHF81 can track the maximum and minimum values along with current readings. The HHF81 displays the flowrate in your choice of knots, meters per second, kilometers per hour, miles per hour, orfeet per minute.
The HHF81 relies upon a low-friction ball bearing mounted wheel design to provide high accuracy at highand low air velocity. The impeller provides excellent accuracy (±3 to 4%) and the ability to measure theslightest breeze (0.3 m/s). For temperature readings, the HHF81 has an internal thermistor or is compatible with any Type K thermocouple with SMP Male connector, and is accurate to ±1°C + 1% of reading. The humidity sensor measures to 95% relative using a high precision thin-film capacitance sensor with fast response to humidity changes. The Light measurement utilizes an exclusive photo diode and color correctionfilter light sensor.
SPECIFICATIONS
AIR VELOCITY
Measurement Range: 80 to 5910 ft/min, 0.4 to 30.0 m/s, 0.9 to 67.0 mph, 1.4 to 108.0 km/hr, 0.8 to 58.3 knots, 0.8 to 58.3 knots
Resolution: 1 ft/min, 0.1 m/s, 0.1 mph, 0.1 km/hr, 0.1 knots
Accuracy:
≤20 m/s: 3% FS
>20 m/s: 4% FS
TEMPERATURE (Internal Thermistor)
Measurement Range: 0 to 50°C (32 to 122°F)
Resolution: 0.1°C/°F
Accuracy: ±1.2°C (±2.5°F)
Operational Temperature: 0 to 50°C (32 to 122°F)
TEMPERATURE (External Type K Thermocouple)
Measurement Range: -100 to 1300°C (-148 to 2372°F)
Resolution: 0.1°F/°C
Accuracy: ±(1% + 1°C) of rdg [±(1% + 2°F) of rdg]
HUMIDITY
Measurement Range: 10 to 95%
Resolution: 0.1%
Accuracy:
<70% RH: ±4% of rdg
≥70% RH: ±(4% rdg + 1.2 % RH)
Operational Humidity Max.: 80% RH
LIGHT LUX
Measurement Range: 0 to 2200 Lux, 1800 to 20000 Lux, 0 to 204.0 Fc, 170 to 2000 Fc
Resolution: 1 Lux, 10 Lux, 0.1 Ft-cd, 1 Ft-cd
Accuracy: ±(5% rdg +8 dgt)
Overange Display: “----”
Battery: 9V (included)
Power Consumption: Approx. DC 6.2 mA
Weight: 160 g (0.4 lb) battery included
Dimensions: 156 x 60 x 33 mm (6.14 x 2.36 x 1.29") Anemometer | Automation | Accelerometers | Calibrator | Cartridge Heaters | Chart Recorders | Cryogenics | Custom Pressure Transducers | Data Loggers | Data Acquisition | Dial Thermometers | Fiber Optics | Fiber Optic Temperature Measurement | Flexible Heaters | Flow Meters | Glass Bulb Thermometers | Grippers | Heaters | Humidity Measurement | Integrated Circuit Sensors | Immersion Heaters | Infrared Thermometers | Level Measurement | Load Cells | M12 Temperature Connectors | Magnetic Flow Meter | Panel Meter | PID Controllers | pH meter | Pressure Gauges | Pressure Transducers | Pressure Transmitters | Rotameters | RTD | Remote Process Monitoring | Sanitary Sensors | Signal Conditioners | Stepper Motors | Strain Gages | Strip Heaters | Temperature Controllers | Temperature Labels | Temperature Measurement | Temperature Sensor Manufacturing | Temperature Sensors | Temperature Transmitters | Thermal Imagers | Thermistors | Thermocouple | Thermocouple Wire | Thermowell | Ultrasonic Flow Meters | Vortex Flow Meter | Wireless Sensors