Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
Product Groups
Linear Variable Inductive Transducers for Position Sensing (Heavy-Duty)
TRODEKS Engineering | Thermocouples, Pressure Transducers, Flow Meters, PID Controllers
LDI-127
PLACE ORDER 
  • Heavy-Duty, Long Lasting, Contactless Device
  • Excellent Stroke-to-Length Ratio
  • 27 mm (1.05") Diameter Anodized Aluminum Housing Sealed to IP67
  • Wide Choice of Range: 25 to 200 mm (1 to 8") Full Scale
  • High Accuracy with Low Linearity Error
  • Radial Cable Exit with Swivel Rod Eye Ends
  • Designed to Operate Under Adverse Temperature, Vibration, Shock, and Humidity Conditions
 Specs
 Manuals (contact with email : [email protected])
 Print
Description

Description

The LDI-127 Series LVIT (Linear Variable InductiveTransducer) position sensors from trodeks® arecontactless devices designed for factory automationand a variety of industrial and commercial applicationssuch as solar cell positioners, wind turbine prop pitchand brakes, chute or gate positions on off-road oragri-vehicles and packing equipment. The modulardesign, high end performance and excellent stroke-to-lengthratio make the LDI-127 sensors ideal for in-plantor mobile equipment OEMs.

With their compact device, superior performance, andexcellent stroke-to-length ratio, the LDI-127 sensorsare ideal for both industrial testing, laboratories, andOEM applications.

LDI-127 sensors are offered in 5 full scale ranges from25 to 200 mm (1 to 8"). Operating from a variety ofDC voltages, these sensors offer a choice of outputsand all include the Field Programmability calibrationfeature. LDI-127 products come with radial exitingcable and two swivel rod eye ends for easy installation.The LDI series also include a smaller body version,the LDI-119, for those applications not requiring aheavy-duty unit.

Specifications
Analog I/Os:
    0 to 10V output with 12 to 30V input, 35 mA max;
    4 to 20 mA (3-wire) output with 18 to 30V input,
    60 mA max 75°C (167°F max)
Measuring Range: 25 to 200 mm (1 to 8") full scale
Linearity Error: ±0.15% of Full Scale Output (FSO) typical,±0.25% max
Resolution: 0.025% of FS
Update Rate: 300 Hz nominal
Operating Temperature: -20 to 85°C (-4 to 185°F)
Temperature Coefficient: 0.015% of FS/degree°C
Vibration: 5 to 20 Hz, 0.5" p-p; 20 to 2000 Hz, 4.2 g p-p
Shock: 1000 g, 11 ms
Terminations: IEC IP67Humidity: 95% RH, non-condensing
Housing Material: Aluminum
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors